journal article·2023-01Open access

Durability of cantilever inlay-retained fixed dental prosthesis fabricated from multilayered zirconia ceramics with different designs

Ziad N. Al-Dwairi, Latifah Al-Aghbari, Nadin Al-Haj Husain, Mutlu Özcan

Abstract

PURPOSE: The purpose of this in-vitro study was to investigate the effect of framework design on fracture resistance and failure modes of cantilever inlay-retained fixed partial dentures (IRFDPs) fabricated from two multilayered monolithic zirconia materials. MATERIALS AND METHODS: Seventy-two natural premolar teeth were prepared as abutments for cantilever IRFDPs using three designs: mesial-occlusal (MO) inlay with short buccal and palatal wings (D1), MO inlay with long palatal wing (D2), MO inlay with long palatal wing and occlusal extension (D3). Full-contoured IRFDPs were fabricated from two monolithic zirconia materials; IPS e.max ZirCAD Prime and Zolid Gen-X. Adhesive surfaces were air-abraded and bonded with MDP-containing resin cement. Specimens were subjected to thermocycling (5-55 °C, 5000 cycles); then, mechanical loading (1.2 × 10⁶ cycles, 49 N). Surviving specimens were loaded until failure in the universal testing machine. All specimens were examined under stereomicroscope, and two samples from each group were evaluated using Scanning Electron Microscope. RESULTS: Mean failure loads were not significantly different between different framework designs or between two materials. However, IPS e.max ZirCAD Prime showed significantly higher failure rate than Zolid Gen-X during dynamic fatigue (p = 0.009). Samples with D1 design showed higher debonding rate, D2 failed mainly by fracture of the palatal wing and debonding, and D3 failed mainly by fracture of the abutment tooth. Debonded restorations showed mainly mixed failures. CONCLUSION: Cantilever IRFDPs with framework designs that maximize adhesion to enamel exhibited promising results. IPS e.max ZirCAD Prime was more susceptible to fractures with the long palatal wing design.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Health and Care Utilization · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Zirconia ceramic inlay-retained fixed dental prostheses–first clinical results with a new design10.1016/j.jdent.2010.12.005 ↗
2. Classification and properties of dental zirconia as implant fixtures and superstructures10.3390/ma14174879 ↗
3. Influence of different preparation forms on the loading-bearing capacity of zirconia cantilever FDPs. A laboratory study10.1016/j.jpor.2018.10.010 ↗
4. In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region10.1016/j.prosdent.2017.03.006 ↗
5. All-ceramic inlay-retained fixed dental prostheses for replacing posterior missing teeth: a systematic review10.1016/j.jpor.2017.06.007 ↗
6. Five-year clinical outcome of posterior zirconia ceramic inlay-retained FDPs with a modified design10.1016/j.jdent.2015.11.001 ↗
7. All-ceramic inlay-retained fixed dental prostheses: an update
8. A systematic review of the survival and complication rates of inlay-retained fixed dental prostheses10.1016/j.jdent.2017.02.006 ↗
9. Tooth structure removal associated with various preparation designs for anterior teeth10.1067/mpr.2002.124094 ↗
10. Evidence-based decision making: replacement of the single missing tooth
11. Occlusal forces during chewing and swallowing as measured by sound transmission10.1016/0022-3913(81)90455-8 ↗
12. Limits of human bite strength10.1016/0022-3913(86)90480-4 ↗
13. Evaluation of fracture resistance of inlay-retained fixed partial dentures fabricated with different monolithic zirconia materials10.1016/j.prosdent.2017.06.008 ↗
14. Eight-year outcome of posterior inlay-retained all-ceramic fixed dental prostheses10.1016/j.jdent.2010.07.012 ↗
15. Resin-bonded prostheses for posterior teeth10.1016/0022-3913(92)90321-Z ↗
16. Probing the interfacial strength of novel multi-layer zirconias10.1016/j.dental.2019.10.008 ↗
17. Effect of ceramic material type on the fracture load of inlay-retained and full-coverage fixed dental prostheses
18. Bonding to oxide ceramics—laboratory testing versus clinical outcome10.1016/j.dental.2014.06.007 ↗
19. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses10.1016/j.jdent.2016.11.003 ↗
20. Ten-year survival of anterior all-ceramic resin-bonded fixed dental prostheses
21. In vitro fracture resistance of posterior metal-ceramic and all-ceramic inlay-retained resin-bonded fixed partial dentures10.1016/j.prosdent.2004.07.001 ↗
22. Effect of thermocycling on bond strength of luting cements to zirconia ceramic10.1016/j.dental.2005.04.016 ↗
23. The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prostheses10.3109/00016357.2010.549508 ↗
24. Fracture strength of prefabricated all-ceramic posterior inlay-retained fixed dental prostheses10.1016/j.dental.2009.07.013 ↗
25. Comparison between novel strength-gradient and color-gradient multilayered zirconia using conventional and high-speed sintering10.1016/j.jmbbm.2020.103977 ↗
26. Lithium disilicate restorations fatigue testing parameters: a systematic review10.1111/jopr.12376 ↗
27. Fracture resistance of the veneering on inlay-retained zirconia ceramic fixed partial dentures10.1080/00016350500206710 ↗
28. All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study10.1016/j.jdent.2008.04.017 ↗
29. Adhesion to zirconia used for dental restorations: a systematic review and meta-analysis
30. Load‐bearing capacity of all‐ceramic posterior inlay‐retained fixed dental prostheses10.1111/j.1600-0722.2009.00626.x ↗
31. Clinical efficacy of methods for bonding to zirconia: a systematic review10.1016/j.prosdent.2019.12.017 ↗
32. Veneered zirconia inlay-retained fixed dental prostheses: 10-year results from a prospective clinical study10.1016/j.jdent.2017.06.008 ↗
33. Approach for valuating the influence of laboratory simulation10.1016/j.dental.2008.08.009 ↗
34. Influence of resilient support of abutment teeth on fracture resistance of all-ceramic fixed partial dentures: an in vitro study
35. Retrospective clinical study of single-retainer cantilever anterior and posterior glass-ceramic resin-bonded fixed dental prostheses at a mean follow-up of 6 years10.11607/ijp.3368 ↗
36. Load to failure of three different monolithic zirconia inlay-retained fixed dental prosthesis designs with three surface treatments10.14295/bds.2020.v23i2.1896 ↗
37. Inlay‐retained cantilever fixed dental prostheses to substitute a single premolar: impact of zirconia framework design after dynamic loading10.1111/eos.12134 ↗
38. Resin-bonded inlay retainer prostheses for posterior teeth, A 5-year clinical study
39. The all‐ceramic, inlay supported fixed partial denture. Part 1. Ceramic inlay preparation design: a literature review10.1111/j.1834-7819.2010.01214.x ↗
40. The all‐ceramic, inlay supported fixed partial denture. Part 2. Fixed partial denture design: a finite element analysis10.1111/j.1834-7819.2011.01341.x ↗
41. The all‐ceramic, inlay supported fixed partial denture. Part 3. Experimental approach for validating the finite element analysis10.1111/j.1834-7819.2011.01638.x ↗
42. 4 Effect of different artificial aging conditions on ceramic-composite bond strength
43. Clinical performance of anterior resin-bonded fixed dental prostheses with different framework designs: a systematic review and meta-analysis10.1016/j.jdent.2016.02.003 ↗
44. A new design for all-ceramic inlay-retained fixed partial dentures: a report of 2 cases
45. A comparison of the fracture resistance of three machinable ceramics after thermal and mechanical fatigue10.1016/j.prosdent.2014.03.005 ↗
46. Probabilistic fatigue analysis of all-ceramic crowns based on the finite element method10.1016/j.jbiomech.2010.04.030 ↗