Investigation on primary stability of dental implants through considering peri-implant bone damage, caused by small and large deformations: A validated non-linear micro finite element study
Source abstract
Abstract
Primary stability of a dental implant is defined as its ability to resist the applied load without showing excessive damage in peri-implant bone, which is a prerequisite for secondary stability, and consequently for implantation success. The main goal of this study was to develop a validated micro-finite element (μFE) approach to assess the primary stability of dental implants in terms of stiffness, stiffness reduction, and irreversible displacement of the bone-implant system, subjected to an increasing step-wise quasi-static compressive loading-unloading test. The μFE models were generated based on the μCT images of bone, taken from extracted bovine tibia trabecular bone samples after drilling and implantation. A tissue constitutive model was considered for trabecular bone by describing elasto-plasticity with a modified von Mises yield criterion and element deletion technique to account for trabecular bone damage behavior. Then, the obtained force-displacement curves from the simulation were compared with the in-vitro mechanical test curves to evaluate the validity of the model. The results showed that the proposed μFE model could be properly predict the bone-implant system mechanical response in terms of irreversible displacement (R2 = 0.99), stiffness (R2 = 0.77), and stiffness reduction (R2 = 0.72) of the bone-implant construct for all the applied displacements without a significant difference from the unit slope and zero intercept of the QQ-plot (p-value<0.05). Moreover, a qualitative agreement was seen between the peri-implant bone damage predicted by the μFE model and the observed from μCT images. The adopted methodology used in this study can predict the mechanical failure response of the bone-implant system, which can be employed as a representative tool to study the effects of various dental implant design parameters on the primary stability with the ultimate goal of optimizing dental implants design.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Methods used to assess implant stability: current status
2. Towards validation of computational analyses of peri-implant displacements by means of experimentally obtained displacement maps10.1080/10255842.2010.537263 ↗
3. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
4. In vitro biomechanical and histological assessment of pilot hole diameter for positive‐profile external skeletal fixation pins in canine tibiae10.1111/j.1532-950X.1996.tb01443.x ↗
5. How to select the elastic modulus for cancellous bone in patient-specific continuum models of the spine10.1007/BF02344727 ↗
6. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
7. Immediate post-extraction implants subject to immediate loading: a meta-analytic study10.4317/medoral.16918 ↗
8. Quantitative X-ray μCT measurement of the effect of ore characteristics on non-surface mineral grain leaching10.3390/min10090746 ↗
9. Dynamic modelling and simulation of dental implant insertion process—a finite element study10.1016/j.finel.2011.03.005 ↗
10. Effects of biomechanical properties of the bone–implant interface on dental implant stability: from in silico approaches to the patient's mouth10.1146/annurev-bioeng-071813-104854 ↗
11. Limitations of the continuum assumption in cancellous bone10.1016/0021-9290(88)90257-6 ↗
12. Hosseini · 2013
13. Mechanical tests and finite element models for bone holding power of tibial locking screws10.1016/j.clinbiomech.2004.04.012 ↗
14. Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study10.1016/j.jdent.2008.02.015 ↗
15. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
16. Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model10.1016/j.medengphy.2012.10.006 ↗
17. Mechanical behavior of damaged trabecular bone10.1016/0021-9290(94)90040-X ↗
18. An investigation of the inelastic behaviour of trabecular bone during the press-fit implantation of a tibial component in total knee arthroplasty10.1016/j.medengphy.2013.05.007 ↗
19. Measurement of bone damage caused by quasi-static compressive loading-unloading to explore dental implants stability: simultaneous use of in-vitro tests, μ-CT images, and digital volume correlation
20. Bone damage during dental implant insertion: a pilot study combining strain gauge and histologic analysis10.3390/app12010291 ↗
21. Trabecular bone strains around a dental implant and associated micromotions—a micro-CT-based three-dimensional finite element study10.1016/j.jbiomech.2010.01.003 ↗
22. Linear and nonlinear analyses of femoral fractures: computational/experimental study10.1016/j.jbiomech.2018.08.003 ↗
23. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
24. Implant stability in different implantation stages: analysis of various interface conditions10.1016/j.imu.2020.100317 ↗
25. A nonlinear homogenized finite element analysis of the primary stability of the bone–implant interface10.1007/s10237-018-1038-3 ↗
26. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis10.1016/j.jmbbm.2019.06.024 ↗
27. Explicit non-linear finite element analysis for prediction of primary stability in uncemented total hip arthroplasty
28. A review on recent advances in the constitutive modeling of bone tissue10.1007/s11914-020-00631-1 ↗
29. Primary stability: the password of implant integration10.4103/0974-6781.102223 ↗
30. Nonlinear micro‐CT based FE modeling of trabecular bone—sensitivity of apparent response to tissue constitutive law and bone volume fraction10.1002/cnm.2941 ↗
31. Screw insertion in trabecular bone causes peri-implant bone damage10.1016/j.medengphy.2016.01.006 ↗
32. A novel in silico method to quantify primary stability of screws in trabecular bone10.1002/jor.23551 ↗
33. Computational analysis of primary implant stability in trabecular bone10.1016/j.jbiomech.2014.12.008 ↗
34. Efficient materially nonlinear μ FE solver for simulations of trabecular bone failure10.1007/s10237-019-01254-x ↗
35. Systémes · 2015
36. Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae10.1007/s10237-011-0347-6 ↗
37. Immediate loading in implant dentistry
38. Computational strategies for iterative solutions of large FEM applications employing voxel data10.1002/(SICI)1097-0207(19960830)39:16<2743::AID-NME974>3.0.CO;2-A ↗
39. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
40. Peroperative estimation of bone quality and primary dental implant stability10.1016/j.jmbbm.2018.12.035 ↗
41. Dependence of trabecular damage on mechanical strain10.1002/jor.1100150522 ↗
42. Elastic modulus and hardness of cortical and trabecular bovine bone measured by nanoindentation10.1016/S1003-6326(06)60293-8 ↗
43. An explicit micro‐FE approach to investigate the post‐yield behaviour of trabecular bone under large deformations10.1002/cnm.3188 ↗
44. The discrete nature of trabecular bone microarchitecture affects implant stability10.1016/j.jbiomech.2011.12.024 ↗
45. Implant stability is affected by local bone microstructural quality10.1016/j.bone.2011.05.001 ↗
46. Damage accumulation in vertebral trabecular bone depends on loading mode and direction10.1016/j.jbiomech.2011.01.018 ↗
47. Young’s modulus of trabecular bone at the tissue level: a review10.1016/j.actbio.2018.08.001 ↗
48. 3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors10.1016/j.jmbbm.2020.103858 ↗
49. European Society of Biomechanics SM Perren Award 2016: a statistical damage model for bone tissue based on distinct compressive and tensile cracks10.1016/j.jbiomech.2016.09.045 ↗