journal article·2023-12Open access

The influence of cross shear and contact pressure on the wear of UHMWPE-on-PEEK-OPTIMA™ for use in total knee replacement

Raelene M. Cowie, Adam Briscoe, Louise M. Jennings

Abstract

PEEK-OPTIMA™ polymer is being considered as an alternative material to cobalt chrome in the femoral component of total knee arthroplasty to give a metal-free knee replacement system. Simple geometry pin-on-plate wear simulation can be used to systematically investigate and understand the wear of materials under many different conditions. The aim of this study was to investigate the wear of UHMWPE-on-PEEK-OPTIMA™ under a range of contact pressure (2.1-80 MPa) and cross-shear ratio (0-0.18) conditions. With increasing contact pressure, there was a trend of decreasing UHMWPE wear factor with a significant difference (p<0.001) in the wear factor of UHMWPE under the different contact pressure conditions of interest. Under uniaxial motion (cross-shear ratio = 0), the wear of UHMWPE was low, introducing multi-axial motion increased the wear of the UHMWPE. There was a significant difference (p<0.01) in the wear factor at different cross-shear ratios however, post hoc analysis showed only the study carried out under unidirectional motion to be significantly different from the other conditions. With varying contact pressure and cross-shear ratio, the wear of UHMWPE against PEEK-OPTIMA™ polymer showed similar trends to previous studies of UHMWPE-on-cobalt chrome.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Computational wear prediction of artificial knee joints based on a new wear law and formulation10.1016/j.jbiomech.2011.01.027 ↗
2. Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene10.1177/0954411912459423 ↗
3. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements10.1016/j.jmbbm.2017.11.022 ↗
4. The wear of metals under unlubricated conditions
5. The influence of stress conditions on the wear of UHMWPE for total joint replacements10.1023/A:1018515318630 ↗
6. The biotribology of PEEK-on-HXLPE bearings is comparable to traditional bearings on a multidirectional pin-on-disk tester10.1007/s11999-016-4989-7 ↗
7. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?10.1007/s11999-009-1119-9 ↗
8. The importance of multidirectional motion on the wear of polyethylene10.1243/PIME_PROC_1996_210_408_02 ↗
9. Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications10.1016/j.jmbbm.2016.06.005 ↗
10. Wear properties of poly-ether-ether-ketone bearing combinations under zero and cross shear kinematics in total knee arthroplasty10.1002/jbm.b.34136 ↗
11. The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses––a biomechanical study10.1016/S0268-0033(02)00189-4 ↗
12. Third body damage and wear in arthroplasty bearing materials: a review of laboratory methods10.1016/j.bbiosy.2021.100028 ↗
13. Cowie · 2023
14. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: a preliminary study10.1177/0954411916667410 ↗
15. Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene10.1177/0954411916651461 ↗
16. Wear and friction of UHMWPE-on-PEEK OPTIMA10.1016/j.jmbbm.2018.09.021 ↗
17. Third body wear of UHMWPE-on-PEEK-OPTIMA10.3390/ma13061264 ↗
18. The influence of lubricant temperature on the wear of total knee replacements10.1049/bsb2.12061 ↗
19. The effects of cyclic loading and motion on the implant–cement interface and cement mantle of PEEK and cobalt–chromium femoral total knee arthroplasty implants: a preliminary study10.3390/ma13153323 ↗
20. Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models10.1016/j.jbiomech.2021.110270 ↗
21. Feasibility and safety of a cemented PEEK-on-PE knee replacement in a goat model: a preliminary study10.1111/aor.13101 ↗
22. Polyethylene contact stresses, articular congruity, and knee alignment10.1097/00003086-200111000-00029 ↗
23. Wear of PEEK-OPTIMA® and PEEK-OPTIMA®-Wear Performance articulating against highly cross-linked polyethylene10.1177/0954411915576353 ↗
24. A novel method for the prediction of functional biological activity of polyethylene wear debris10.1243/0954411011533599 ↗
25. Experimental evaluation of an elastic foundation model to predict contact pressures in knee replacements10.1016/S0021-9290(03)00176-3 ↗
26. Wear of crosslinked polyethylene under different tribological conditions10.1007/s10856-006-7309-z ↗
27. Sensitivity to implant materials in patients with total knee arthroplasties10.1016/j.biomaterials.2007.11.038 ↗
28. PEEK as a replacement for CoCrMo in knee prostheses: pin-on-disc wear test of PEEK-on-polyethylene articulations10.1016/j.biotri.2021.100189 ↗
29. (iv) Enhancing the safety and reliability of joint replacement implants
30. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE10.1016/j.jbiomech.2007.09.005 ↗
31. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure10.1243/09544119JEIM431 ↗
32. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
33. 3 - packaging and sterilization of UHMWPE
34. A new formulation for the prediction of polyethylene wear in artificial hip joints10.1243/09544119JEIM819 ↗
35. Characteristics of wear particles and wear behavior of retrieved PEEK-on-HXLPE total knee implants: a preliminary study10.1039/C8RA04661A ↗
36. Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head10.1302/0301-620X.80B5.0800894 ↗
37. 2022
38. Does a PEEK femoral TKA implant preserve intact femoral surface strains compared with CoCr? A preliminary laboratory study10.1007/s11999-016-4801-8 ↗
39. Tibiofemoral contact areas and pressures in six high flexion knees10.1007/s00264-007-0478-7 ↗
40. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding10.1016/S0043-1648(00)00522-6 ↗
41. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene10.1016/S0043-1648(96)07362-0 ↗
42. Wear mechanism and debris analysis of PEEK as an alternative to CoCrMo in the femoral component of total knee replacement10.1007/s40544-022-0700-z ↗