Bioactive glass microspheres as osteopromotive inlays in macrotextured surfaces of Ti and CoCr alloy bone implants: Trapezoidal surface grooves without inlay most efficient in resisting torsional forces
Source abstract
Abstract
We have tested the efficacy of porous bioactive glass (BG) inlays in enhancement of implant osseointegration. A total of 24 sheep underwent bilateral surgical implantation of three parallel implants on the anteromedial cortical surface of each tibia. The disc-shaped implants made of Ti6Al4V or cobalt chromium (CoCr) alloys had two parallel surface grooves (trapezoidal space with bottom widening) filled with sintered 100% bioactive glass microspheres or a selected mixture of bioactive and biocompatible glass microspheres. The surface of uncoated control implants was smooth, grit-blasted or had unfilled grooves. A subgroup of control smooth CoCr implants was coated with two or three BG layers. Implant incorporation with bone was evaluated using torque testing to failure, scanning electron microscopy and morphometry at 12 and 25 weeks. A total of 144 in vivo implants and 16 ex vivo cemented control implants were analyzed. Control Ti6Al4V implants with unfilled trapezoidal grooves showed highest torsional failure loads with excellent ingrowth of new bone and remodeling of ingrown bone into lamellar bone. Implants with BG inlays and microroughened control Ti6Al4V implants showed significantly lower torsional failure loads than control Ti6Al4V implants with unfilled grooves. In conclusion, BG inlays failed to enhance biological implant fixation. Macrotextured surface was more effective than grit-blasting in promotion of mechanical incorporation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Facial Trauma and Fracture Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. In vivo evaluation of titanium implants coated with bioactive glass by pulsed laser deposition10.1007/s10856-007-3153-z ↗
2. Laser cladding of bioactive glass coatings10.1016/j.actbio.2009.08.010 ↗
3. Bioceramics: the effect of surface reactivity on bone formation and bone cell function10.1016/S0142-9612(99)00181-7 ↗
4. Sol–gel coatings for protection and bioactivation of metals used in orthopaedic devices10.1039/B401370K ↗
5. Influence of biomaterial surface texture on bone ingrowth in the rabbit femur10.1002/jor.1100140316 ↗
6. Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae10.1359/jbmr.090808 ↗
7. Glass-based coating for titanium implant alloys10.1002/(SICI)1097-4636(19990915)46:4<549::AID-JBM13>3.0.CO;2-M ↗
8. Effect of bioactive glasses on angiogenesis: a review of in vitro and in vivo evidences10.1089/ten.teb.2009.0416 ↗
9. Genetic design of bioactive glass10.1016/j.jeurceramsoc.2008.08.002 ↗
10. Macro-structural effect of metal surfaces treated using computer-assisted yttrium-aluminum-garnet laser scanning on bone–implant fixation10.1002/jbm.a.30277 ↗
11. Biologic significance of surface microroughening in bone incorporation of porous bioactive glass implants10.1002/jbm.a.10501 ↗
12. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro10.1016/j.jbiomech.2004.05.023 ↗
13. Bioceramic inlays do not improve mechanical incorporation of grit-blasted titanium stems in the proximal sheep femur10.1002/jbm.a.32494 ↗
14. Bone-bonding behaviour of plasma-sprayed coatings of Bioglass, AW-glass ceramic, and tricalcium phosphate on titanium alloy10.1002/(SICI)1097-4636(199602)30:2<261::AID-JBM17>3.0.CO;2-P ↗
15. The bonding of Bioglass® to a cobalt-chromium surgical implant alloy10.1016/0142-9612(86)90064-5 ↗
16. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
17. Interfaces in graded coatings on titanium-based implants10.1002/jbm.a.31935 ↗
18. Coating titanium implants with bioglass and with hydroxyapatite10.1007/s002640050282 ↗
19. Interfacial fracture toughness between bovine cortical bone and cements10.1016/S0142-9612(02)00464-7 ↗
20. Cementless total hip replacement using second-generation components: a 12- to 16-year follow-up10.1302/0301-620X.92B12.24582 ↗
21. Quality of intertrochanteric cancellous bone as predictor of femoral stem RSA migration in cementless total hip arthroplasty10.1016/j.jbiomech.2010.10.012 ↗
22. Implants coated with bioactive glass by CO2-laser, an in vivo study10.1023/B:JMSM.0000032820.50983.c1 ↗
23. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry10.1080/17453670710014310 ↗
24. Modular femoral stems for revision total hip arthroplasty10.1007/s11999-010-1561-8 ↗
25. Effect of micro-roughness produced by TiO2 blasting–tensile testing of bone attachment by using coin-shaped implants10.1016/S0142-9612(02)00167-9 ↗
26. Effect of zoledronic acid on incorporation of a bioceramic bone graft substitute10.1016/j.bone.2005.09.016 ↗
27. Fabrication and characterization of bioactive glass coatings produced by the ion beam sputter deposition technique10.1023/A:1014050715535 ↗
28. Differential healing response of bone adjacent to porous implants coated with hydroxyapatite and 45S5 bioactive glass10.1002/1097-4636(20010615)55:4<603::AID-JBM1054>3.0.CO;2-N ↗
29. Cancellous bone osseointegration is enhanced by in vivo loading10.1089/ten.tec.2009.0776 ↗