journal article·2019-08

Assessment of the uniaxial experimental parameters utilised for the mechanical testing of bovine pericardium

K. Joyce, Y. Rochev, S. Rahmani

Publisher page

Abstract

Bovine pericardium (BP) is an extensively used biomaterial utilised in a wide range of biomedical devices such as bioprosthetic heart valves. However, the mechanical testing techniques that assess soft biomaterial tissue like BP are varied with no common method utilised across the literature, producing variations and contradictions in reported values. Uniaxial testing is a common technique used to measure traditional mechanical characteristics of ultimate tensile strength (UTS), modulus and the percentage strain at failure. The aim of this study was to take two standard uniaxial test parameters, strain rate and the number of preconditioning cycles and to elucidate recommendations for the standardisation of a uniaxial method, while also measuring not so common parameters of low modulus and hysteresis. Samples post uniaxial testing were treated and analysed with scanning electron microscopy (SEM) and an imaging software (ImageJ) to measure the effect of the parameters on the crimping structure and orientation of the collagen fibres. The study recommends an extension rate of 10 mm/min and 5 preconditioning load-unload cycles as a starting point for the standardisation of a uniaxial testing method. The image analysis of the collagen structure carried out provides a quantitative assessment of the BP post mechanical testing and allows for a better understanding of the behaviour of BP under stress.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. 5840-1:2015 · 2015
2. 5840/2005 · 2007
3. Mechanical testing of pericardium for manufacturing prosthetic heart valves10.1093/icvts/ivv282 ↗
4. Characterizing the collagen fiber orientation in pericardial leaflets under mechanical loading conditions10.1007/s10439-012-0696-z ↗
5. Functional analysis of bioprosthetic heart valves10.1016/j.jbiomech.2004.07.007 ↗
6. The role of collagen cross-links in biomechanical behavior of human aortic heart valve leaflets--relevance for tissue engineering10.1089/ten.2006.0279 ↗
7. Reynolds shear stress for textile prosthetic heart valves in relation to fabric design10.1016/j.jmbbm.2016.01.016 ↗
8. Evaluation of transcatheter heart valve biomaterials: biomechanical characterization of bovine and porcine pericardium10.1016/j.jmbbm.2017.08.013 ↗
9. Hydration water and bulk water in proteins have distinct properties in radial distributions calculated from 105 atomic resolution crystal structures10.1021/jp802795a ↗
10. Donkey pericardium as an alternative bioprosthetic heart valve material10.1111/j.1525-1594.2012.01549.x ↗
11. Changes in the mechanical properties of chemically treated bovine pericardium after a short uniaxial cyclic test10.1111/j.1525-1594.2012.01538.x ↗
12. In vitro determination of the curvatures and bending strains acting on the leaflets of polyurethane trileaflet heart valves during leaflet motion10.1243/PIME_PROC_1995_209_351_02 ↗
13. Atomic force microscopy and mechanical testing of bovine pericardium irradiated to radiotherapy doses10.1016/j.radphyschem.2013.09.017 ↗
14. 2016
15. Fibrillar structure and mechanical properties of collagen10.1006/jsbi.1998.3966 ↗
16. Uniaxial and biaxial tensile strength of calf pericardium used in the construction of bioprostheses: biomaterial selection criteria10.1106/77V6-PMK9-DUH4-LLR8 ↗
17. Mechanical effects of increases in the load applied in uniaxial and biaxial tensile testing: part I. Calf pericardium10.1023/A:1014388618649 ↗
18. A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants10.1177/0885328212465482 ↗
19. Harding · 2011 · 1
20. The elastic properties of Elastin 1,210.1021/ja01557a016 ↗
21. Transplantation material bovine pericardium: biomechanical and immunogenic characteristics after decellularization vs. glutaraldehyde-fixing10.1111/j.1399-3089.2012.00719.x ↗
22. A comparative study on mechanical and biochemical properties of bovine pericardium after single or double crosslinking treatment10.4070/kcj.2012.42.3.154 ↗
23. Glutaraldehyde as a fixative in bioprostheses and drug delivery matrices10.1016/0142-9612(96)82721-9 ↗
24. Elastic behavior of porcine coronary artery tissue under uniaxial and equibiaxial tension10.1114/B:ABME.0000042224.23927.ce ↗
25. Biaxial mechanical/structural effects of equibiaxial strain during crosslinking of bovine pericardial xenograft materials10.1016/S0142-9612(98)00142-2 ↗
26. Molecular orientation of collagen in intact planar connective tissues under biaxial stretch10.1016/j.actbio.2004.09.007 ↗
27. Validation of the shrinkage temperature of animal tissue for bioprosthetic heart valve application by differential scanning calorimetry10.1016/0142-9612(95)92125-P ↗
28. Decellularization of pericardial tissue and its impact on tensile viscoelasticity and glycosaminoglycan content10.1016/j.actbio.2010.11.017 ↗
29. Biological materials: structure and mechanical properties10.1016/j.pmatsci.2007.05.002 ↗
30. Biomechanical characterization of decellularized and cross-linked bovine pericardium
31. The impact of long term freezing on the mechanical properties of porcine aortic tissue10.1016/j.jmbbm.2014.04.015 ↗
32. Assessment of pericardium in cardiac bioprostheses: a review10.1177/088532829901300404 ↗
33. Comparison of the mechanical behaviors of biological tissues subjected to uniaxial tensile testing: pig, calf and ostrich pericardium sutured with Gore-Tex10.1016/S0142-9612(02)00536-7 ↗
34. Experimental investigation of collagen waviness and orientation in the arterial adventitia using confocal laser scanning microscopy10.1007/s10237-011-0325-z ↗
35. Orthotropic mechanical properties of chemically treated bovine pericardium10.1114/1.135 ↗
36. The micromechanical behavior of lyophilized glutaraldehyde-treated bovine pericardium under uniaxial tension10.1016/j.jmbbm.2010.06.010 ↗
37. NIH Image to ImageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
38. Bioprosthetic heart valves: modes of failure10.1111/j.1365-2559.2008.03190.x ↗
39. Response of heterograft heart valve biomaterials to moderate cyclic loading10.1002/jbm.a.30031 ↗
40. Degradation potential of biological tissues fixed with various fixatives: an in vitro study10.1002/(SICI)1097-4636(199705)35:2<147::AID-JBM2>3.0.CO;2-N ↗
41. Feasibility study of a natural crosslinking reagent for biological tissue fixation10.1002/(SICI)1097-4636(19981215)42:4<560::AID-JBM12>3.0.CO;2-I ↗
42. Crosslinking characteristics and mechanical properties of a bovine pericardium fixed with a naturally occurring crosslinking agent10.1002/(SICI)1097-4636(199911)47:2<116::AID-JBM2>3.0.CO;2-J ↗
43. Mechanical properties of a porcine aortic valve fixed with a naturally occurring crosslinking agent10.1016/S0142-9612(99)00069-1 ↗
44. Evaluation of shrinkage temperature of bovine pericardium tissue for bioprosthetic heart valve application by differential scanning calorimetry and freeze-drying microscopy10.1590/S1516-14392007000100002 ↗
45. Tear and decohesion of bovine pericardial tissue10.1016/j.jmbbm.2016.06.002 ↗
46. The extension rate independence of the hysteresis in glutaraldehyde-fixed bovine pericardium10.1016/0142-9612(87)90064-0 ↗
47. The role of elastin in aortic valve mechanics10.1016/S0021-9290(97)00122-X ↗
48. Will heart valve tissue engineering change the world?10.1038/ncpcardio0112 ↗
49. Modeling the response of exogenously crosslinked tissue to cyclic loading: the effects of permanent set10.1016/j.jmbbm.2017.07.013 ↗
50. Mechanics of native bovine pericardium: II. A structure based model for the anisotropic mechanical behaviour of the tissue10.1016/0142-9612(94)90250-X ↗
51. Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valves10.1002/jbm.820280107 ↗