Full-field displacement measurement of corneoscleral shells by combining multi-camera speckle interferometry with 3D shape reconstruction
Source abstract
Abstract
Changes in the biomechanical properties of the connective tissue of the eye occur with age and underlie the development of several ocular diseases, such as glaucoma, myopia, and keratoconus. The biomechanical dynamics of ocular connective tissue are measured by ex vivo inflation testing, in which intraocular pressure (IOP) is varied and optical methods are used to produce maps of corneal and scleral displacement. Current optical methods are limited by acquisition rate, occlusions, poor spatial resolution, and insufficient 3D mapping. We developed an interferometric optical method integrates four-camera electronic speckle pattern interferometry (ESPI) and a novel three-dimensional (3D) shape reconstruction process to measure shape and full-field mechanical deformations of corneal and scleral shells during ex vivo inflation testing. Each camera provides accurate measurements of the laser beam phase related to deformations of the specimen surface; a multi-view stereovision method generates the shape of the specimen and a functional form that links every pixel of a given camera to 3D points on the specimen's visible surface. In this way, dynamic deformations of the specimen are localized, with quantification of the time-dependent 3D displacements of the specimen at nanometric accuracy. The ESPI-3D system is suitable for analyzing scleral deformation and morphological changes caused by time-varying IOP.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal surgery and disorders · Glaucoma and retinal disorders · Ocular Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Full-field deformation of bovine cornea under constrained inflation conditions10.1016/j.biomaterials.2008.06.011 ↗
2. Laser speckle decorrelation in NDT10.1016/S0143-8166(00)00057-9 ↗
3. A multi-camera speckle interferometer for dynamic full-field 3D displacement measurement: validation and inflation testing of a human eye sclera10.1016/j.optlaseng.2018.03.012 ↗
4. Age-related differences in the elasticity of the human cornea10.1167/iovs.09-4798 ↗
5. Overview of 3-D shape measurement using optical methods10.1117/1.602438 ↗
6. CloudCompare
7. Biomechanics of the human posterior sclera: age- and glaucoma-related changes measured using inflation testing10.1167/iovs.11-8009 ↗
8. Phase-shifting speckle interferometry10.1364/AO.24.003053 ↗
9. The mechanical environment of the optic nerve head in glaucoma10.1097/OPX.0b013e31817841cb ↗
10. Experimental assessment of human corneal hysteresis10.1080/02713680701882519 ↗
11. Regional variation in the biomechanical properties of the human sclera10.1016/j.exer.2010.02.010 ↗
12. Compensation method for obtaining accurate, sub-micrometer displacement measurements of immersed specimens using electronic speckle interferometry10.1364/BOE.3.000407 ↗
13. Regional variations in mechanical strain in the posterior human sclera10.1167/iovs.12-9668 ↗
14. Fuhrmann · 2014 · 11
15. Two-dimensional phase unwrapping: theory, algorithms, and software
16. Scleral biomechanics in the aging monkey eye10.1167/iovs.08-3363 ↗
17. “Peripapillary and posterior scleral mechanics—part II: experimental and inverse finite element characterization10.1115/1.3113683 ↗
18. Mechanical considerations in myopia: relative effects of accommodation, convergence, intraocular pressure, and the extraocular muscles10.1097/00006324-198012000-00004 ↗
19. Material properties of the posterior human sclera10.1016/j.jmbbm.2013.03.027 ↗
20. Age-and race-related differences in human scleral material properties,10.1167/iovs.14-14029 ↗
21. Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgery10.1016/j.jcrs.2004.10.038 ↗
22. The effects of the extraocular muscles on eye impact force-deflection and globe rupture response10.1016/j.jbiomech.2008.07.037 ↗
23. Corneal biomechanical changes after collagen cross-linking from porcine eye inflation experiments10.1167/iovs.09-4536 ↗
24. Virtual simulation of eyeball and extraocular muscle reaction during cataract surgery10.1016/j.proeng.2012.07.155 ↗
25. Ma · 2012 · vol. 26
26. Long-term changes in corneal morphology induced by overnight orthokeratology10.3109/02713683.2011.593723 ↗
27. Sequential-digital image correlation for mapping human posterior sclera and optic nerve head deformation10.1115/1.4026224 ↗
28. Open globe injuries: factors predictive of poor outcome10.1038/sj.eye.6702099 ↗
29. Photomechanics
30. The mechanics of corneal deformation and rupture for penetrating injury in the human eye10.1016/j.injury.2017.11.037 ↗
31. Acute retinal ganglion cell injury caused by intraocular pressure spikes is mediated by endogenous extracellular ATP10.1111/j.1460-9568.2007.05528.x ↗
32. SURE: photogrammetric surface reconstruction from imagery
33. Biomechanical properties of keratoconus suspect eyes10.1167/iovs.09-4304 ↗
34. Fluctuations of intraocular pressure during the day in open-angle glaucoma, normal-tension glaucoma and normal subjects10.1159/000027290 ↗
35. The african descent and glaucoma evaluation study (ADAGES): design and baseline data10.1001/archophthalmol.2009.187 ↗
36. Using mesh morphing to study the influence of geometry on biomechanics: an example in ocular biomechanics
37. Development of a novel instrument to measure the pulsatile movement of ocular tissues10.1016/j.exer.2010.03.022 ↗
38. The magnitude and time course of IOP change in response to body position change in nonhuman primates measured using continuous IOP telemetry10.1167/iovs.17-22858 ↗
39. Wu · 2011
40. Towards linear-time incremental structure from motion
41. Multicore bundle adjustment
42. Flexible camera calibration by viewing a plane from unknown orientations