Optimal surgical component alignment minimizes TKR wear – An in silico study with nine alignment parameters
Source abstract
Abstract
Currently, preclinical mechanical wear testing of total knee replacements (TKRs) is done using ideally aligned components using standardized TKR level walking under either force or displacement-control regimes. To understand the influence of implant alignment and testing control regime, we studied the effect of nine component alignment parameters on TKR volumetric wear in silico. We used a computational framework combining Latin Hypercube sampling design of experiments, finite element analysis, and a numerical model of polyethylene wear, to create a predictive model of how component alignment affects wear rate for each control regime. Nine component alignment parameters were investigated, five femoral variables and four tibial variables. To investigate perturbations of the nine implant alignment variables, two separate 300-point designs were executed, one for each control regime. The results were then used to generate surrogate statistical models using stepwise multiple linear regression. Wear at the neutral position was 4.5mm3/million cycle and 8.6mm3/million cycle for displacement and force-control, respectively. Stepwise multiple linear regression surrogate models were highly significant for each control regime, but force-control generated a stronger predictive model, with a higher R2, more included terms, and a lower RMSE. Both models predicted transverse plane rotational mismatch can lead to large changes in predicted wear; a transverse plane alignment mismatch of 15° can elicit a change in wear of up to 5mm3/million cycle, almost double that of neutral alignment. Therefore, transverse plane alignment is particularly important when considering failure of the implant due to wear.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (72)
Show source-provided references
1. AJRR · 2020
2. The relevance of ligament balancing in total knee arthroplasty: how important is it? A systematic review of the literature
3. Efficient computational method for assessing the effects of implant positioning in cementless total hip replacements10.1016/j.jbiomech.2010.12.027 ↗
4. Constitutive modeling of ultra-high molecular weight polyethylene under large-deformation and cyclic loading conditions10.1016/S0142-9612(01)00367-2 ↗
5. Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing10.1002/jbm.a.32728 ↗
6. Kinematic navigation in total knee replacement — experience from the first 50 cases10.1016/S0929-6646(09)60186-8 ↗
7. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol)10.1302/0301-620X.86B6.15456 ↗
8. Computer-assisted knee arthroplasty versus a conventional jig-based technique10.1302/0301-620X.86B3.14643 ↗
9. The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses––a biomechanical study10.1016/S0268-0033(02)00189-4 ↗
10. What host factors affect aseptic loosening after THA and TKA?10.1007/s11999-015-4220-2 ↗
11. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique10.1016/j.arth.2005.04.004 ↗
12. Instability after total knee arthroplasty10.1016/j.ocl.2015.09.007 ↗
13. Stair ascent kinematics affect UHMWPE wear and damage in total knee replacements10.1002/jbm.b.30451 ↗
14. Changing demographics of patients with total joint replacement10.1097/01.blo.0000188066.01833.4f ↗
15. Instability in primary total knee arthroplasty10.3928/01477447-20110714-46 ↗
16. Predicting wear of UHMWPE: decreasing wear rate following a change in direction10.1016/j.wear.2011.06.006 ↗
17. Wear of polyethylene against oxidized zirconium femoral components: effect of aggressive kinematic conditions and malalignment in total knee arthroplasty10.1016/j.arth.2011.06.002 ↗
18. Combined probabilistic and principal component analysis approach for multivariate sensitivity evaluation and application to implanted patellofemoral mechanics10.1016/j.jbiomech.2010.08.016 ↗
19. Computationally efficient prediction of bone–implant interface micromotion of a cementless tibial tray during gait10.1016/j.jbiomech.2014.02.018 ↗
20. Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms10.1016/j.actbio.2013.05.005 ↗
21. Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases
22. Failure analysis of retrieved polyethylene insert in total knee replacement
23. Does malalignment affect revision rate in total knee replacements: a systematic review of the literature10.1186/s40064-015-1604-4 ↗
24. Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control
25. Polyethylene damage and knee kinematics after total knee arthroplasty10.1097/00003086-200111000-00050 ↗
26. Iman
27. Comparison of the hospital cost of primary and revision total hip arthroplasty after cost containment10.3928/0147-7447-19990201-07 ↗
28. ISO 14243-1 · 2009
29. ISO 14243-3 · 2014
30. Comparison of wear of mobile and fixed bearing knees tested in a knee simulator10.1016/S0043-1648(03)00272-2 ↗
31. The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement10.1016/j.jmbbm.2019.103386 ↗
32. Efficient global optimization of expensive black-box functions10.1023/A:1008306431147 ↗
33. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading10.1016/j.jbiomech.2006.07.027 ↗
34. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
35. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 203010.1007/s11999-009-0834-6 ↗
36. Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 202110.2106/JBJS.M.00285 ↗
37. The increasing financial burden of knee revision surgery in the United States10.1097/01.blo.0000214424.67453.9a ↗
38. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function10.1016/j.arth.2008.03.002 ↗
39. The dramatic increase in total knee replacement utilization rates in the United States cannot Be fully explained by growth in population size and the obesity epidemic10.2106/JBJS.J.01958 ↗
40. Mell · 2018
41. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - a parametric finite element study of ISO 14243-310.1016/j.jbiomech.2019.03.027 ↗
42. Computational parametric studies for preclinical evaluation of total knee replacements
43. Sensitivity of total knee replacement wear to variability in motion and load input: a parametric finite element analysis study10.1002/jor.24755 ↗
44. Arthroplasty in young adults: options, techniques, trends, and results10.1007/s12178-014-9213-3 ↗
45. Mechanisms of failure in total knee arthroplasty10.1097/00003086-198801000-00010 ↗
46. Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert10.1016/j.arth.2006.07.014 ↗
47. National Joint Registry
48. Variability of TKR knee kinematics and relationship with gait kinetics: implications for total knee wear
49. Internal rotational error of the tibial component is a major cause of pain after total knee replacement10.1302/0301-620X.92B9.23516 ↗
50. Probabilistic computational modeling of total knee replacement wear10.1016/j.wear.2007.06.010 ↗
51. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review10.1007/s00167-017-4823-0 ↗
52. Conventional versus highly cross-linked polyethylene in primary total knee replacement: a comparison of revision rates using data from the national joint registry for England, Wales, and Northern Ireland10.2106/JBJS.19.00031 ↗
53. The epidemiology of revision total knee and hip arthroplasty in England and Wales: a comparative analysis with projections for the United States. a study using the national joint registry dataset10.1302/0301-620X.97B8.35170 ↗
54. Quantifying cross-shear under translation, rolling, and rotation, and its effect on UHMWPE wear10.1016/j.wear.2014.03.001 ↗
55. Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living10.1002/jor.21104 ↗
56. Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement10.1002/jor.24710 ↗
57. A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty10.1007/s00586-010-1386-x ↗
58. Cross-shear in metal-on-polyethylene articulation of orthopaedic implants and its relationship to wear10.1016/j.wear.2013.01.069 ↗
59. Fluid composition influences wear testing of artificial knee implants
60. Differences in wear between load and displacement control tested total knee replacements10.1016/j.wear.2009.01.028 ↗
61. Modes of failure of total knee arthroplasty: registries and realities10.1055/s-0034-1396014 ↗
62. Effect of tibial component varus on wear in total knee arthroplasty10.1016/j.knee.2011.11.003 ↗
63. In-silico wear prediction for knee replacements-methodology and corroboration10.1016/j.jbiomech.2009.04.022 ↗
64. 2021
65. 2021
66. 2021
67. Patient-reported outcomes following total knee replacement in patients <65 Years of age-A systematic review and meta-analysis10.3390/jcm9103150 ↗
68. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding10.1016/S0043-1648(00)00522-6 ↗
69. Wear and structural fatigue simulation of crosslinked ultra-high molecular weight polyethylene for hip and knee bearing applications10.1520/JAI11593 ↗
70. Estimating the burden of total knee replacement in the United States10.2106/JBJS.L.00206 ↗
71. The effect of valgus/varus malalignment on load distribution in total knee replacements10.1016/j.jbiomech.2004.02.024 ↗
72. Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions10.1007/s10856-015-5470-y ↗