Effect of preparation design on fracture strength of compromised molars restored with lithium disilicate inlay and overlay restorations: An in vitro and in silico study

Jelte W. Hofsteenge, Marco Aurelio Carvalho, Pauline M. Borghans, Marco S. Cune, Mutlu Özcan, Pascal Magne, Marco M.M. Gresnigt

Abstract

PURPOSE: The objective of this study was to determine the influence of different preparation designs on the fracture strength, failure type, repairability, formation of polymerization-induced cracks, and tooth deformation of structurally compromised molars restored with lithium disilicate inlays and overlays in combination with Immediate Dentin Sealing (IDS). MATERIAL AND METHODS: Human molars (N = 64) were randomly assigned to four different preparation designs: Undermined Inlay (UI), Extended Inlay (EI), Restricted Overlay (RO), and Extended Overlay (EO). The teeth were restored using lithium disilicate partial restorations and subjected to thermomechanical fatigue in a chewing simulator (1,2 × 10 (Mondelli et al., 2007) cycles on 50 N, 8000x 5-55 °C), followed by load to failure testing. In silico finite element analysis was conducted to assess tooth deformation. Polymerization-induced cracks were evaluated using optical microscopy and transillumination. Fracture strengths were statistically analyzed using a Kruskal-Wallis test, while the failure mode, repairability, and polymerization cracks were analyzed using Fisher exact test. RESULTS: The propagation of polymerization-induced cracks did not significantly differ among preparation designs. All specimens withstood chewing simulator fatigue, with no visible cracks in teeth or restorations. Fracture strength was significantly influenced by preparation design, with restricted overlay (RO) showing higher fracture strength compared to extended inlay (EI) (p = .042). Tooth deformation and fracture resistance correlated between in vitro and in silico analyses). UI exhibited a statistically less destructive failure pattern than EO (p < .01) and RO (p = .036). No statistically significant influence of the preparation design on repairability was observed. Groups with higher repairability rates experienced increased tooth deformation, leading to less catastrophic failures. CONCLUSIONS: The preparation design affected the fracture strength of compromised molars restored with lithium disilicate inlays and overlays, with significantly lower fracture strength for an extended inlay. The failure pattern of lithium disilicate overlays is significantly more destructive than that of undermined and extended inlays. The finite element analysis showed more tooth deformation in the inlay restorations, with lower forces in the roots, leading to less destructive fractures. Since cusp coverage restorations fracture in a more destructive manner, this study suggests the undermined inlay preparation design as a viable option for restoring weakened cusps.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Health and Care Utilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Longevity of ceramic onlays: a systematic review10.1111/jerd.12384 ↗
2. Effect of cavity design and material type on fracture resistance and failure pattern of molars restored by computer-aided design/computer-aided manufacturing inlays/onlays10.4103/1735-3327.311421 ↗
3. Fracture resistance of partial indirect restorations made with CAD/CAM Technology. A systematic review and meta-analysis10.3390/jcm8111932 ↗
4. Mechanical behavior of Class I cavities restored by different material combinations under loading and polymerization shrinkage stress. A 3D-FEA study
5. Fatigue resistance and crack propensity of large MOD composite resin restorations: direct versus CAD/CAM inlays10.1016/j.dental.2012.11.013 ↗
6. Clinical long-term evaluation and failure characteristics of 1,335 all-ceramic restorations10.1016/S0022-3913(12)60068-7 ↗
7. Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations10.1016/j.jmbbm.2017.04.002 ↗
8. Randomized clinical trial on the survival of lithium disilicate posterior partial restorations bonded using immediate or delayed dentin sealing after 3 years of function10.1016/j.jdent.2019.02.001 ↗
9. Prospective randomized clinical trial on the survival of lithium disilicate posterior partial crowns bonded using immediate or delayed dentin sealing: short-term results on tooth sensitivity and patient satisfaction10.2341/18-047-C ↗
10. Prospective clinical evaluation of 765 partial glass-ceramic posterior restorations luted using photo-polymerized resin composite in conjunction with immediate dentin sealing10.1007/s00784-020-03454-7 ↗
11. Up to 12 years clinical evaluation of 197 partial indirect restorations with deep margin elevation in the posterior region10.1016/j.jdent.2019.103227 ↗
12. Influence of Deep Margin Elevation and preparation design on the fracture strength of indirectly restored molars
13. 3D finite element model based on CT images of tooth: a simplified method of modeling10.20396/bjos.v19i0.8658910 ↗
14. A comparison of stresses in molar teeth restored with inlays and direct restorations, including polymerization shrinkage of composite resin and tooth loading during mastication10.1016/j.dental.2014.11.016 ↗
15. *Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences10.3758/BF03193146 ↗
16. Occlusal forces during chewing and swallowing as measured by sound transmission10.1016/0022-3913(81)90455-8 ↗
17. Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns10.1016/j.prosdent.2014.02.008 ↗
18. Clinical longevity of ceramic laminate veneers bonded to teeth with and without existing composite restorations up to 40 months10.1007/s00784-012-0790-5 ↗
19. Performance of ceramic laminate veneers with immediate dentine sealing: an 11 year prospective clinical trial10.1016/j.dental.2019.04.008 ↗
20. Effect of immediate dentine sealing on the aging and fracture strength of lithium disilicate inlays and overlays
21. Influence of preparation design and restorative material on fatigue and fracture strength of restored maxillary premolars10.2341/20-032-L ↗
22. Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement
23. Application and validation of a three-dimensional mathematical model of the human masticatory system in vivo10.1016/0021-9290(92)90274-5 ↗
24. A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces10.1016/0021-9290(88)90219-9 ↗
25. Influence of the ceramic translucency on the relative degree of conversion of a direct composite and dual-curing resin cement through lithium disilicate onlays and endocrowns
26. A randomized clinical trial of cusp-replacing resin composite restorations: efficiency and short-term effectiveness
27. Bone stress analysis of various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study
28. Multi-factorial analysis of a cusp-replacing adhesive premolar restoration: a finite element study10.1016/j.jdent.2007.11.016 ↗
29. Short-fiber reinforced MOD restorations of molars with severely undermined cusps
30. Computer-aided-design/computer-assisted-manufactured adhesive restoration of molars with a compromised cusp: effect of fiber-reinforced immediate dentin sealing and cusp overlap on fatigue strength10.1111/j.1708-8240.2011.00433.x ↗
31. Composite resin core buildups with and without post for the restoration of endodontically treated molars without ferrule10.2341/14-258-L ↗
32. 10.9-year survival of pressed acid etched monolithic e.max lithium disilicate glass-ceramic partial coverage restorations: performance and outcomes as a function of tooth position, age, sex, and the type of partial coverage restoration (inlay or onlay)10.1016/j.prosdent.2020.07.015 ↗
33. Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition
34. Tooth structure and fracture strength of cavities10.1590/S0103-64402007000200009 ↗
35. Measurement of masticatory forces and implant loads: a methodologic clinical study
36. Wheeler's dental anatomy, physiology, and occlusion
37. Equivalent Young's modulus of composite resin for simulation of stress during dental restoration10.1016/j.dental.2016.10.007 ↗
38. Nonretentive bonded ceramic partial crowns: concept and simplified protocol for long-lasting dental restorations
39. Immediate dentin sealing for indirect bonded restorations10.1016/j.jpor.2016.04.001 ↗
40. Influence of silane type and application time on the bond strength to leucite reinforced ceramics
41. Evidence-based concepts and procedures for bonded inlays and onlays. Part II. Guidelines for cavity preparation and restoration fabrication
42. Direct resin composite restoration of endodontically-treated permanent molars in adolescents: bite force and patient-specific finite element analysis10.1590/1678-7757-2019-0544 ↗
43. Correlation coefficients: appropriate use and interpretation10.1213/ANE.0000000000002864 ↗
44. Elastic properties of lithium disilicate versus feldspathic inlays: effect on the bonding by 3D finite element analysis10.1111/jopr.12550 ↗
45. Maximum voluntary molar bite force in subjects with normal occlusion10.1093/ejo/cjq097 ↗
46. Fracture resistance of prepared premolars restored with bonded new lab composite and all-ceramic inlay/onlay restorations: laboratory study10.1111/jerd.12364 ↗
47. Effects of different ceramic and composite materials on stress distribution in inlay and onlay cavities: 3-D finite element analysis10.4012/dmj.28.661 ↗
48. Fracture resistance of CAD/CAM-Fabricated lithium disilicate MOD inlays and onlays with various cavity preparation designs10.1111/jopr.12787 ↗