journal article·2022-06

Exploring a parallel rheological framework to capture the mechanical behaviour of a thin-strut polymeric bioresorbable coronary scaffold

Ben Hoddy, Naveed Ahmed, Kadem Al-lamee, Nial Bullett, Neil W. Bressloff

Publisher page

Abstract

Computational modelling of bioresorbable scaffolds (BRS) has employed several different material property models, ranging from those based on simple elasto-plastic theory through to anisotropic parallel network models that capture the viscoelastic-plastic behaviour observed in poly-l-lactic acid (PLLA). The increased complexity of higher fidelity material models, particularly in terms of calibration to in-vitro data, can limit their use. Consequently, their suitability for predicting the mechanical response of next-generation BRS is not well understood. Therefore, we have used the Bergstrom-Boyce (BB) parallel network material model, implemented in Abaqus/Explicit (Dassault Systemes), to investigate the mechanical response of a scaffold based upon the ArterioSorbTM BRS (Arterius Ltd, Leeds, UK). In-silico crimping, balloon expansion and radial crushing were simulated and validated against an analogous in-vitro test. Calibration of the model to uniaxial tensile test data was considered given the model's strain rate dependency and the inability to maintain the natural time period of the simulation when using the explicit solution method in finite element analysis. The isotropic limitations of this model were also explored. The model was also compared to an elasto-plastic model developed by the authors in previous work. Relative to bench-top measurements, prediction of the final diameter and radial strength of the scaffold by the BB model was found to be significantly more accurate than other models, within 2% of the in-vitro result. Additionally, the effect of the crimping strategy and an elevated ambient temperature upon the in-silico prediction of the post-crimping scaffold diameter were investigated. A multi-step crimping process with holding to facilitate stress relaxation and the lower stresses induced by the increased temperature were found to improve the accuracy of the predicted post-crimping scaffold diameter.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Orthopaedic implants and arthroplasty · Coronary Interventions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Al-Lamee · 2019
2. From the real device to the digital twin: A coupled experimental-numerical strategy to investigate a novel bioresorbable vascular scaffold10.1371/journal.pone.0252788 ↗
3. Comprehensive computational analysis of the crimping procedure of PLLA BVS: Effects of material viscous-plastic and temperature dependent behavior10.1016/j.jmbbm.2021.104713 ↗
4. Bergström · 2015
5. Constitutive modeling of the large strain time-dependent behavior of elastomers10.1016/S0022-5096(97)00075-6 ↗
6. Large strain time-dependent behavior of filled elastomers10.1016/S0167-6636(00)00028-4 ↗
7. Constitutive modeling of the time-dependent and cyclic loading of elastomers and application to soft biological tissues10.1016/S0167-6636(01)00070-9 ↗
8. An overview of mechanical properties and material modeling of polylactide (PLA) for medical applications10.1007/s10439-015-1455-8 ↗
9. Recent advances in plastic stents: a comprehensive review
10. Multi-objective optimisation of material properties and strut geometry for poly (l-lactic acid) coronary stents using response surface methodology
11. Experimental mechanical testing of poly (l-lactide)(PLLA) to facilitate pre-degradation characteristics for application in cardiovascular stenting10.1016/j.polymertesting.2016.07.011 ↗
12. Computational analysis of the utilisation of the shape memory effect and balloon expansion in fully polymeric stent deployment10.1007/s13239-017-0333-y ↗
13. Computational bench testing to evaluate the short-term mechanical performance of a polymeric stent10.1007/s13239-015-0235-9 ↗
14. Constitutive models of rubber elasticity: a review10.5254/1.3547602 ↗
15. Bressloff, N.W., Pant, S., Al-Lamee, K., 2017. US 9,707,109 B2.
16. Realistic finite element-based stent design: the impact of balloon folding10.1016/j.jbiomech.2007.08.014 ↗
17. DS SIMULIA · 2018
18. Eswaran, S.K., Kelley, J.A., Bergström, J.S., Giddings, V.L., 2011. Material modeling of polylactide. In: SIMULIA Customer Conference. pp. 1–11.
19. Investigating the material modelling of a polymeric bioresorbable scaffold via in-silico and in-vitro testing10.1016/j.jmbbm.2021.104557 ↗
20. Approximation of the inverse langevin function revisited10.1007/s00397-014-0802-2 ↗
21. Simulated versus physical bench tests: The economic evaluation of the InSilc platform for designing, developing, and assessing vascular scaffolds10.1097/MD.0000000000026198 ↗
22. Multiobjective design optimisation of coronary stents10.1016/j.biomaterials.2011.07.059 ↗
23. Computational analysis of the radial mechanical performance of PLLA coronary artery stents10.1016/j.medengphy.2014.09.014 ↗
24. PolymerFEM · 2021
25. Computational analysis of mechanical stress–strain interaction of a bioresorbable scaffold with blood vessel10.1016/j.jbiomech.2016.05.035 ↗
26. Modelling the mechanical and strain recovery behaviour of partially crystalline PLA10.3390/polym11081342 ↗
27. Multimodal loading environment predicts bioresorbable vascular scaffolds’ durability
28. Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents10.1016/j.jmbbm.2016.08.033 ↗
29. Effect of working environment and procedural strategies on mechanical performance of bioresorbable vascular scaffolds10.1016/j.actbio.2018.10.020 ↗