journal article·2023-03Open access

How does bicycling affect the longevity of Total Hip Arthroplasty? A finite element wear analysis

Shawn Ming Song Toh, Ariyan Ashkanfar, Russell English, Glynn Rothwell, David J. Langton, Thomas J. Joyce

Abstract

As the number of young and active individuals undergoing Total Hip Arthroplasty (THA) are increasing yearly, there is a need for hip prostheses to have increased longevity. Current investigations into the longevity of these prostheses only include walking as the patient's activity as there is limited data on the amount and intensity of other activity performed by the patient. To further understand the evolution of wear and increase the longevity of these implants, the impact of different activities on the hip prosthesis needs to be investigated. In this study, a finite element model and wear algorithm was developed to simulate both walking and bicycling over a 5-year period. The XLPE acetabular cup volumetric wear rate was found to be 33 mm3/yr while the femoral head taper wear rates were between 0.01 – 0.39 mm3/yr. The results showed that by adding bicycling of up to 80 km per week with normal walking activity, the XLPE mean volumetric wear rate increased by 67% and the metallic mean volumetric wear rate by 11%. However, the patient may gain further health benefits from this additional activity. Assistive electric bikes may also be used to further reduce the loads on the hip joint, allowing for lower amounts of wear.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Jogging after total hip arthroplasty10.1177/0363546513506866 ↗
2. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings10.1177/0954411915620454 ↗
3. Anissian · 1999
4. Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation10.1016/j.jbiomech.2017.07.027 ↗
5. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
6. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients10.1302/0301-620X.99B12.BJJ-2017-0353.R1 ↗
7. Sports, joint injury, and posttraumatic osteoarthritis10.2519/jospt.2003.33.10.578 ↗
8. Clinical biomechanics of wear in total hip arthroplasty
9. In vivo hip joint loads and pedal forces during ergometer cycling10.1016/j.jbiomech.2017.06.047 ↗
10. What are young patients doing after hip reconstruction?10.1016/j.arth.2012.02.001 ↗
11. Highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty: a 10-year double-blinded randomized controlled trial10.2106/JBJS.16.00878 ↗
12. Employer travel plans, cycling and gender: will travel plan measures improve the outlook for cycling to work in the UK?10.1016/S1361-9209(02)00018-4 ↗
13. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
14. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
15. Tibiofemoral joint forces during ergometer cycling10.1177/036354658601400407 ↗
16. Friction in femoral prosthesis and photoelastic model cone taper joints10.1243/PIME_PROC_1989_203_003_01 ↗
17. Computational hip joint simulator for wear and heat generation10.1016/j.jbiomech.2006.12.005 ↗
18. Wear in retrieved Charnley acetabular sockets10.1243/PIME_PROC_1996_210_413_02 ↗
19. Harms · 2018
20. Wear rates of larger-diameter cross-linked polyethylene at 5 to 13 Years: does liner thickness or component position matter?10.1016/j.arth.2016.11.022 ↗
21. Wear rates of XLPE nearly 50% lower than previously thought after adjusting for initial creep: an RCT comparing 4 bearing combinations10.2106/JBJS.OA.19.00066 ↗
22. Exercise recommendations after total joint replacement10.2165/00007256-200232070-00003 ↗
23. Taper junction failure in large-diameter metal-on-metal bearings10.1302/2046-3758.14.2000047 ↗
24. Total hip wear assessment: a Comparison between computational and in vitro wear assessment techniques using ISO 14242 loading and kinematics10.1115/1.3049477 ↗
25. Sports participation following total hip arthroplasty
26. What's new in hip replacement10.2106/JBJS.21.00612 ↗
27. 2021
28. Health benefits of cycling: a systematic review10.1111/j.1600-0838.2011.01299.x ↗
29. Does impact sport activity influence total hip arthroplasty durability?10.1007/s11999-012-2362-z ↗
30. Quantitative assessment of walking activity after total hip or knee replacement10.2106/00004623-199801000-00010 ↗
31. Who are Bicyclists? Why and how much are they Bicycling?10.3141/2134-08 ↗
32. Hip replacement and return to sports10.5960/dzsm.2017.268 ↗
33. 2021
34. Activity recommendations after total hip and knee arthroplasty: a survey of the American association for hip and knee surgeons10.1016/j.arth.2009.05.014 ↗
35. Sport und Endoprothese10.1016/j.orthtr.2019.03.003 ↗
36. Computational method for bearing surface wear prediction in total hip replacements10.1016/j.jmbbm.2021.104507 ↗
37. The relation between body weight and wear in Total Hip Prosthesis: a finite element study10.1016/j.cmpbup.2022.100060 ↗
38. Multi-scale evaluation of wear in UHMWPE-metal hip implants tested in a hip joint simulator10.1016/j.biotri.2015.08.001 ↗
39. Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator10.4028/www.scientific.net/JBBTE.7.7 ↗
40. A finite element methodology for wear–fatigue analysis for modular hip implants10.1016/j.triboint.2013.02.016 ↗