journal article·2023-10

Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders

Sydney Hitchon, William Anderson, Jaques S. Milner, Gregory Hong, Todor Ivanov, Ryan Willing, David Holdsworth

Publisher page

Abstract

Porous additively-manufactured structures could have a niche in orthopaedic implants, due to their potential to reduce stiffness (stress-shielding), improve bony ingrowth, and potential to house reservoirs of drug-eluting non-structural biomaterials. Computer aided design and finite element (FE) modelling plays an important role in the design of porous structured biomedical implants; however it is important to validate both their static and fatigue behaviours using experimental testing. This study compared the mechanical behaviors of titanium cylindrical gyroid structures of varying porosities using physical testing of additively manufactured prototypes and FE models. There was agreement in the measured and predicted relationships between porosity and apparent modulus of elasticity. As porosity increased (and wall thickness decreased), the structures failed at a lower number of cycles when loaded at the same percentage of their yield strengths. Calibration of the fatigue strength coefficient from a previously published value of 1586.5 MPa-1225 MPa greatly improved the fatigue life prediction accuracy for all the gyroid structures. Nevertheless, differences of up to 54% in the predicted versus experimental fatigue lives remained, which could be attributed to difficulties with how the precise time and location of failure is defined in the simulations, and/or minor differences in nominal and actual porosities. Although further calibration and validation should be explored, this study demonstrates that static and fatigue FE-modelling techniques could be used to aid in the design of porous prosthetics.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Bone Tissue Engineering Materials · Cellular and Composite Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Finite element analysis of mechanical behaviour, permeability and fluid induced wall shear stress of high porosity scaffolds with gyroid and lattice-based architectures10.1016/j.jmbbm.2017.07.035 ↗
2. Topology-mechanical property relationship of 3D-printed strut, skeletal, and sheet based periodic metallic cellular materials
3. Fully porous 3D printed titanium femoral stem to reduce stress shielding following total hip arthroplasty10.1002/jor.23445 ↗
4. Controlled drug release from antibiotic-loaded layered double hydroxide coatings on porous titanium implants in a mouse model10.1002/jbm.a.35358 ↗
5. A comparison of all-hexahedra and all-tetrahedra finite element meshes for elastic and elasto-plastic analysis
6. Permeability versus design in TPMS scaffolds10.3390/ma12081313 ↗
7. Design and analysis of porous functionally graded femoral prostheses with improved stress shielding
8. The potential use of a gyroid structure to represent monolithic matrices for bioseparation purposes: fluid dynamics and mass transfer analysis via CFD10.1016/j.seppur.2020.117594 ↗
9. Fatigue lifetime prediction of a reduced-diameter dental implant system: numerical and experimental study10.1016/j.dental.2018.06.002 ↗
10. Porous orthopaedic steel implant as an antibiotic eluting device: prevention of post-surgical infection on an ovine model10.1016/j.ijpharm.2013.04.076 ↗
11. An overview of materials with triply periodic minimal surfaces and related geometry: from biological structures to self-assembled Systems10.1002/adma.201705708 ↗
12. Effective magnetic susceptibility of 3D-printed porous metal scaffolds10.1002/mrm.29136 ↗
13. 2011
14. Multiscale mechanics of triply periodic minimal surfaces of three-dimensional graphene foams10.1021/acs.nanolett.8b01431 ↗
15. Fatigue behaviour of as-built selective laser melted titanium scaffolds with sheet-based gyroid microarchitecture for bone tissue engineering10.1016/j.actbio.2019.05.046 ↗
16. Processing, structure, and properties of additively manufactured titanium scaffolds with gyroid-sheet architecture
17. Porous tantalum structure integrated on Ti6Al4V base by Laser Powder Bed Fusion for enhanced bony-ingrowth implants: in vitro and in vivo validation
18. Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants
19. The influence of selective laser melting defects on the fatigue properties of Ti6Al4V porosity graded gyroids for bone implants10.1016/j.ijmecsci.2020.106180 ↗
20. Process-structure-Property relationships in selective laser melting of porosity graded gyroids
21. Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis10.1016/j.jse.2015.11.011 ↗
22. The effect of inhomogenous trabecular stiffness relationship selection on finite element outcomes for shoulder arthroplasty
23. 2017
24. Generalized application of neuber's rule10.1520/JTE11613J ↗
25. Modal characterization of additively manufactured TPMS structures: comparison between different modeling methods10.1007/s00170-020-06174-0 ↗
26. Surface roughness effects on fatigue behaviour of gyroid cellular structures obtained by additive manufacturing10.1016/j.ijfatigue.2020.105702 ↗
27. Compression-compression fatigue behaviour of gyroid-type triply periodic minimal surface porous structures fabricated by selective laser melting10.1016/j.actamat.2019.09.042 ↗
28. The effects of grit size and blasting pressure on the surface properties of grit blasted Ti6Al4V alloy
29. The select of internal architecture for porous Ti alloy scaffold: a compromise between mechanical properties and permeability10.1016/j.matdes.2020.108754 ↗