journal article·2024-03

Exploration into the microstructural, mechanical, and biological characteristics of the functionally graded 3Y-TZP/Ti6Al4V system as a potential material for dental implants

Yeganeh Moayedee, Leila Nikzad, Houdsa Majidian

Publisher page

Abstract

This study investigated the mechanical, microstructural, and biological properties of 3Y-TZP/Ti6Al4V functionally graded material (FGM) fabricated by the spark plasma sintering (SPS) method. For this purpose, 11 layers of 100-x vol% Ti6Al4V/x vol% Yttria stabilized zirconia (YSZ) (x = 0 to 100) were sintered at 1450 °C and a pressure of 30 MPa for 8 min. To investigate the properties of each layer in more detail, 11 batches of 100-x vol% (Ti6Al4V)/x vol% YSZ (x = 0 to 100) composites were sintered separately with the same sintering conditions mentioned for the FGM sample. Phase identification of the FGM sample showed the formation of Ti3O, c-ZrO2, and Zr3O phases as by-products. A schematic model was proposed for the formation of the mentioned phases with the aid of thermodynamic calculations. The formation of these phases was confirmed by microstructural and elemental tests. The results of the relative density of the samples showed that these values were obtained for each layer above 99%. The microhardness of 590 ± 18 Vickers was obtained for Ti6Al4V; by increasing the amount of 3Y-TZP, this value reached 1510 ± 24 Vickers for the YSZ sample. The fracture toughness value for Ti6Al4V was 39.2 ± 2 MPa m0.5, which was significantly reduced to 4.84 ± 1 MPa m0.5 by adding 10 vol% YSZ. After that, with the further increase of YSZ, this value increased slowly. A similar trend was observed for the bending strength of the samples. By increasing 3Y-TZP from 0 to 30 vol%, the bending strength was decreased from 1556 ± 32 to 272 ± 62 MPa. By further increasing the amount of 3Y-TZP from 30 to 100 vol%, an increase in the bending strength was observed in the samples, which reached 1180 ± 71 MPa for the YSZ sample. The FGM sample showed a brittle fracture despite a metal layer, but a higher bending strength (982 ± 44 MPa) was obtained for this structure than the composite samples. The biological results show that increasing YSZ content leads to a decrease in antimicrobial activity. Additionally, all samples demonstrated high biocompatibility based on MTT cytotoxicity tests after 1 and 7 days of culture.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Toughening of bioceramic composites for bone regeneration10.3390/jcs5100259 ↗
2. Thermal shock resistance of zirconia with 15 mole% titanium10.1111/j.1151-2916.1966.tb13276.x ↗
3. Al(2)O(3)-Ti functionally graded material prepared by spark plasma sintering for orthopaedic applications10.1016/j.jmbbm.2017.04.024 ↗
4. Electrochemical corrosion of Ti-Al2O3 biocomposites in Ringer's solution10.1016/j.jallcom.2018.09.313 ↗
5. Barin · 1989
6. Functionally graded materials: a critical review
7. Fabrication of functionally graded few-layered graphene reinforced Al-4.5 Cu alloy by powder metallurgy10.1016/j.jallcom.2022.166348 ↗
8. SS316L/Al2O3 functionally graded material for potential biomedical applications10.1016/j.matchemphys.2022.126958 ↗
9. Cobalt free refractory high entropy alloys for total joint arthroplasty: in-vitro wear, corrosion and cytocompatibility evaluation10.1016/j.jallcom.2022.168499 ↗
10. Mechanical behavior of AlN/Mo functionally graded materials with various compositional structures10.1016/j.jallcom.2019.152512 ↗
11. Sintering in ceramics
12. Microstructure and mechanical properties of Ti6Al4V alloy consolidated by different sintering techniques10.3390/met9101033 ↗
13. Fabrication of porous materials by spark plasma sintering: a review10.3390/ma12030541 ↗
14. A review on functionally graded ceramic-metal materials
15. Fabrication of a PSZ-Ti functionally graded material by spark plasma sintering and its fracture toughness10.1016/j.msea.2016.11.091 ↗
16. Microstructure and mechanical properties of a novel functionally graded material from Ti6Al4V to Inconel 625 fabricated by dual wire+ arc additive manufacturing10.1016/j.jallcom.2022.163981 ↗
17. Mechanical, corrosion, and wear properties of biomedical Ti–Zr–Nb–Ta–Mo high entropy alloys10.1016/j.jallcom.2020.157997 ↗
18. Biomedical materials and techniques to improve the tribological, mechanical and biomedical properties of orthopedic implants–A review article10.1016/j.jallcom.2017.04.231 ↗
19. Impact of sandblasting on the flexural strength of highly translucent zirconia10.1016/j.jmbbm.2020.104268 ↗
20. Microstructure and thermoelectric properties of the medium-entropy block-textured BiSbTe1. 5Se1. 5 alloy10.1016/j.jallcom.2021.159743 ↗
21. On the fabrication of functional graded 3Y-PSZ/316L materials by SPS: process optimization and characterization of the obtained products10.1016/j.ceramint.2016.02.050 ↗
22. Strain rate dependence of tensile properties and strengthening mechanism of Ti6Al4V alloy undergoing different coverage layers of laser shock peening10.1016/j.surfcoat.2022.128807 ↗
23. Evaluation of chitosan-alginate nanoparticle as A stable antibacterial formula in biological fluids10.24996/ijs.2022.63.6.8 ↗
24. Bioceramic based on zirconium dioxide10.1007/s10717-009-9148-0 ↗
25. Phase transformation induces plasticity with negligible damage in ceria-stabilized zirconia-based ceramics10.1016/j.actamat.2019.10.046 ↗
26. Reaction between titanium and zirconia powders during sintering at 1500 C10.1111/j.1551-2916.2007.01708.x ↗
27. Effects of oxygen and heat treatment on the mechanical properties of alpha and beta titanium alloys10.1007/BF02649267 ↗
28. A review of zirconia-based solid electrolytes10.1007/s11581-016-1880-1 ↗
29. A review on application of FGM fabricated using solid-state processes10.1080/2374068X.2020.1731153 ↗
30. Fabrication of ZrO2/AISI316L functionally graded materials for joint prostheses10.1016/j.msea.2007.05.004 ↗
31. Effect of the nano-fluorapatite ceramic particles on mechanical behavior of fluoride varnishes10.1016/j.matchemphys.2022.126421 ↗
32. Mechanical, electrochemical, and biological properties of YSZ-Mo: a new class of bio-composites10.1016/j.mtla.2022.101515 ↗
33. Fast low-temperature consolidation of a nanostructured 2Ti–ZrO2 composite for biomedical applications10.1016/j.ceramint.2013.10.034 ↗
34. Phase equilibria in the TiO2–YO1. 5–ZrO2 system10.1016/j.jeurceramsoc.2008.03.011 ↗
35. Flexural strength evaluation of multi-cell composite T-shaped concrete-filled steel tubular beams10.3390/ma14112838 ↗
36. Effect of the Ag addition on the compressibility, sintering and properties of Ti6Al4V/xAg composites processed by powder metallurgy10.1016/j.jallcom.2021.161813 ↗
37. Corrosion and tribocorrosion behavior of ZrO2-Al2O3 composite coatings developed by plasma electrolytic oxidation for load-bearing implants10.1016/j.jallcom.2022.165856 ↗
38. Preliminary tribo-electrochemical and biological responses of the Ti-TiB-TiCx in-situ composites intended for load-bearing biomedical implants10.1016/j.jallcom.2021.162965 ↗
39. Development of Vickers hardness prediction models via microstructural analysis and machine learning10.1007/s10853-020-05153-w ↗
40. Thermodynamics and microstructure of Ti–ZrO2 metal–ceramic functionally graded materials10.1016/S0921-5093(00)01045-5 ↗
41. Effect of Ti content on the martensitic transformation in zirconia for Ti–ZrO2 composites10.1016/S0925-8388(00)01272-X ↗
42. Fabrication of PSZ–Ti composites by spark plasma sintering and their mechanical properties10.1016/j.msea.2014.10.062 ↗
43. Trindade · 2022
44. Microstructure and indentation properties of ZrO2/Ti functionally graded materials fabricated by spark plasma sintering10.1016/j.msea.2015.06.005 ↗
45. Properties and applications of titanium alloys: a brief review
46. A functionalized surface modification with vanadium nanoparticles of various valences against implant-associated bloodstream infection10.2147/IJN.S129459 ↗
47. Biocompatibility of materials and development to functionally graded implant for bio-medical application10.1016/j.compscitech.2003.09.005 ↗
48. Observations on the stabilization of zirconia10.1111/j.1151-2916.1956.tb15645.x ↗
49. Microstructure and mechanical properties of Ti-15Mo-xTiC composites fabricated by in-situ reactive sintering and hot swaging10.1016/j.jallcom.2017.12.124 ↗
50. Production and characterization of a bone-like porous Ti/Ti-hydroxyapatite functionally graded material10.1007/s11665-020-05165-2 ↗
51. Development of 3Y-PSZ/AISI 316L composites for joint prostheses10.2320/matertrans.45.3209 ↗
52. Effects of YSZ and nano-ZrO2 contents on the properties of Ti2448-ZrO2 biomedical composites fabricated by SPS10.1016/j.ceramint.2018.04.160 ↗
53. Microstructural evolution, corrosion behavior and cytotoxicity of Ti-6Al-4V/ZrO2 composite fabricated by directed energy deposition for implant biomaterial10.1016/j.jallcom.2021.161820 ↗