Two-versus three-screw osteosynthesis of the mandibular condylar head: A finite element analysis
Source abstract
Abstract
Titanium screws are commonly used for osteosynthesis of mandibular condylar head fractures. Evidence suggests that the insertion of three screws may result in better fracture stability. Two screws only, on the other hand, could reduce adverse effects, mainly bone resorption. This study aimed to investigate the biomechanical differences in mandibular condylar head osteosynthesis with two versus three titanium screws using finite element analysis. A finite element model of the mandible with a right type P condylar head fracture fixed with two or three titanium screws was analyzed in ANSYS Mechanical. The geometry of the model assembly was constructed in ANSYS Spaceclaim. Biomechanical load boundary conditions were obtained from a validated musculoskeletal model in AnyBody Modeling System™. The preprocessing of the finite element model and mapping of the obtained boundary conditions was done in docq VIT. Fracture displacement, fragment deformation, von Mises stress distribution, and reaction forces within the screws were evaluated in ANSYS for three different loading scenarios. Finite element analysis showed similar results when comparing osteosynthesis with two versus three titanium screws for all three loading scenarios. Contralateral molar loading resulted in the highest stress on both the fracture and the screws with the maximum von Mises stress being found at the condylar neck. Stress concentration within the screws was found in the fracture gap and was higher in the lateral fragment. In all scenarios, maximum von Mises stress values were smaller when forces were distributed among three screws. However, stability was also adequate when two screws were used. Mandibular condylar head osteosynthesis with two titanium screws appears to provide sufficient fracture stability. Further clinical studies are needed to clarify the implications of these results.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Facial Trauma and Fracture Management · Orthopedic Surgery and Rehabilitation · Spinal Fractures and Fixation Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Three-dimensional titanium miniplates for fixation of subcondylar mandibular fractures: comparison of five designs using patient-specific finite element analysis10.1016/j.jcms.2017.12.020 ↗
2. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle10.1016/j.bjoms.2012.08.007 ↗
3. Closed versus open treatment of mandibular condylar process fractures: a meta-analysis of retrospective and prospective studies10.1016/j.jcms.2015.07.027 ↗
4. Biomechanical stress distribution on fixation screws used in bilateral sagittal split ramus osteotomy: assessment of 9 methods via finite element method10.1016/j.joms.2010.03.014 ↗
5. Finite element analysis of the human mandible at 3 different stages of life10.1016/j.tripleo.2010.01.025 ↗
6. Using the finite element method to model the biomechanics of the asymmetric mandible before, during and after skeletal correction by distraction osteogenesis10.1080/10255840500237953 ↗
7. Finite element analysis of the human mastication cycle10.1016/j.jmbbm.2014.09.022 ↗
8. The comprehensive AOCMF classification system: mandible fractures-level 3 tutorial
9. Assessment of the biomechanical performance of 5 plating techniques in fixation of mandibular subcondylar fracture using finite element analysis10.1016/j.joms.2015.11.021 ↗
10. Finite element evaluation of three methods of stable fixation of condyle base fractures10.1016/j.ijom.2014.07.011 ↗
11. Validation of a musculo-skeletal model of the mandible and its application to mandibular distraction osteogenesis10.1016/j.jbiomech.2006.06.024 ↗
12. Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks10.1007/s10006-016-0573-2 ↗
13. Effects of condylar fibrocartilage on the biomechanical loading of the human temporomandibular joint in a three-dimensional, nonlinear finite element model10.1016/S1350-4533(02)00191-1 ↗
14. A new method to evaluate the elastic modulus of cortical bone by using a combined computed tomography and finite element approach10.1016/j.compbiomed.2010.02.011 ↗
15. Volumetric evaluated bone resorption after open reduction and internal fixation of condylar head fractures of the mandible10.1016/j.joms.2021.04.018 ↗
16. Assessment of lingual stability in mandible fracture: monocortical versus bicortical fixation using FEM analysis10.1007/s12663-017-1073-0 ↗
17. Long-term results of ORIF of condylar head fractures of the mandible: a prospective 5-year follow-up study of small-fragment positional-screw osteosynthesis (SFPSO)10.1016/j.jcms.2015.02.004 ↗
18. Combined finite-element and rigid-body analysis of human jaw joint dynamics10.1016/j.jbiomech.2004.10.014 ↗
19. Position paper from the IBRA symposium on surgery of the head--the 2nd international symposium for condylar fracture osteosynthesis, marseille, France 201210.1016/j.jcms.2014.03.005 ↗
20. The comprehensive AOCMF classification system: condylar process fractures - level 3 tutorial
21. Biomechanical evaluation of type p condylar head osteosynthesis using conventional small-fragment screws reinforced by a patient specific two-component plate10.1186/s13005-020-00236-0 ↗
22. Condylar remodeling after osteosynthesis of fractures of the condylar head or close to the temporomandibular joint10.1016/j.jcms.2020.02.005 ↗
23. Resorption behaviour of the articular surface dome and functional outcome after open reduction and internal fixation of mandibular condylar head fractures using small-fragment positional screws10.1016/j.jcms.2018.09.008 ↗
24. A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process10.1067/moe.2002.126451 ↗
25. Three-dimensional finite element analysis of mechanical stress in symphyseal fractured human mandible reduced with miniplates during mastication10.1016/j.joms.2009.07.084 ↗
26. Finite element analysis of type B condylar head fractures and osteosynthesis using two positional screws10.1016/j.jcms.2013.06.006 ↗