Tunability of mechanical and biodegradation properties of zinc-based biomaterial with calcium Micronutrient alloying
Source abstract
Abstract
Biodegradable metals are being investigated as temporary implants that dissolve safely in the body after bone regeneration. Zinc (Zn) has an intermediate biodegradation rate between magnesium and stainless steels, yet its degradation rate is too slow to function as a temporary orthopedic implant. Alloying with nutrient elements is considered a strategy to tune its mechanical properties and in vivo biodegradability. Zn/calcium (Zn/Ca) alloys (with 0.5, 1, and 2 wt% Ca) were processed by spark plasma sintering and their microstructure, mechanical, and biodegradation properties were investigated. Ca was distributed in the grain boundary regions of Zn due to its low miscibility in Zn. Furthermore, the corrosion rates of Zn/Ca alloys determined from linear polarization measurements (0.164-0.325 mm/yr) accelerated by at least 10% compared with pure sintered Zn (0.149 mm/yr) with simultaneous dissolution of Zn and Ca, as verified from X-ray diffraction analysis of the corrosion products. The alloy specimens exhibited hardness (52-58 HV) and compressive strength (93-119 MPa) comparable with those of human cortical and cancellous bones (49 HV; 90-209 MPa). This study demonstrated the tunability of the mechanical and biodegradation properties of Zn-based materials by alloying them with a nutrient element for potential application as temporary orthopedic implants.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Rapid microwave sintering of carbon nanotube-filled AZ61 magnesium alloy composites10.1016/j.compositesb.2016.03.041 ↗
2. Finite element simulation of hybrid microwave sintering based on power approach10.1007/s00170-020-05952-0 ↗
3. High temperature tribology of CuMoTaWV high entropy alloy10.1016/j.wear.2018.12.085 ↗
4. 2012
5. 2009
6. 2011
7. 2010
8. 2020
9. The role of mineralization and organic matrix in the microhardness of bone tissue from controls and osteoporotic patients10.1016/j.bone.2008.05.024 ↗
10. Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents10.1002/adma.201300226 ↗
11. A computational thermodynamic assessment of the Ca-Zn system10.1016/S0364-5916(01)00057-8 ↗
12. Preparation and characterization of porous zinc prepared by spark plasma sintering as a material for biodegradable scaffolds10.1016/j.matchemphys.2017.10.008 ↗
13. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
14. Comparative corrosion behavior of Zn with Fe and Mg in the course of immersion degradation in phosphate buffered saline10.1016/j.corsci.2016.05.039 ↗
15. Ermrich · 2013
16. Evolution of metallic cardiovascular stent materials: a comparative study among stainless steel, magnesium and zinc10.1016/j.biomaterials.2019.119641 ↗
17. Cements as bone repair materials
18. In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting10.1016/j.dental.2014.02.008 ↗
19. Magnesium, iron and zinc alloys, the trifecta of bioresorbable orthopaedic and vascular implantation - a review
20. Current status and perspectives of zinc-based absorbable alloys for biomedical applications10.1016/j.actbio.2019.07.034 ↗
21. Experimental methods in chemical engineering: X-ray diffraction spectroscopy—XRD10.1002/cjce.23747 ↗
22. Development of biodegradable Zn-1X binary alloys with nutrient alloying elements Mg, Ca and Sr
23. Mechanical properties, degradation behaviors and biocompatibility evaluation of a biodegradable Zn-Mg-Cu alloy for cardiovascular implants10.1016/j.matlet.2018.09.092 ↗
24. Additively manufactured 316L stainless steel with improved corrosion resistance and biological response for biomedical applications
25. Zinc-based alloys for degradable vascular stent applications10.1016/j.actbio.2018.03.005 ↗
26. CoCrMo cellular structures made by Electron Beam Melting studied by local tomography and finite element modelling10.1016/j.matchar.2016.04.006 ↗
27. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗
28. 2004
29. Superelasticity preservation in dissimilar joint of NiTi shape memory alloy to biomedical PtIr10.1016/j.mtla.2021.101090 ↗
30. Zinc-based biomaterials for regeneration and therapy10.1016/j.tibtech.2018.10.009 ↗
31. Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications10.1016/j.jmbbm.2017.05.013 ↗
32. Critical assessment and thermodynamic modeling of the binary Mg–Zn, Ca–Zn and ternary Mg–Ca–Zn systems10.1016/j.intermet.2009.03.014 ↗
33. Alloying design of biodegradable zinc as promising bone implants for load-bearing applications
34. In vitro and in vivo studies on zinc-hydroxyapatite composites as novel biodegradable metal matrix composite for orthopedic applications10.1016/j.actbio.2018.03.007 ↗
35. Fatigue behavior of high-strength steel S135 under coupling multi-factor in complex environments10.1016/j.msea.2018.03.093 ↗
36. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
37. Calcium and bone10.1016/j.clinbiochem.2012.05.006 ↗
38. Effects of Ca concentration on degradation behavior of Zn-x Ca alloys in Hank’s solution10.1016/j.matlet.2018.02.018 ↗
39. Wire-based directed energy deposition of NiTiTa shape memory alloys: microstructure, phase transformation, electrochemistry, X-ray visibility and mechanical properties