journal article·2024-04Open access

Investigation of cell-accelerated corrosion (CAC) on the CoCrMo alloy with segregation banding: Hip implant applications

Hemalatha Kanniyappan, Kai-yuan Cheng, Ravindra V. Badhe, Mozart Neto, Divya Bijukumar, Mark Barba, Robin Pourzal, Mathew Mathew

Abstract

Metal alloy microstructure plays a crucial role in corrosion associated with total hip replacement (THR). THR is a prominent strategy that uses metal implants such as cobalt-chromium-molybdenum (CoCrMo) alloys due to their advantageous biological and mechanical properties. Despite all benefits, these implants undergo corrosion and wear processes in-vivo in a synergistic manner called tribocorrosion. Also, the implant retrieval findings reported that fretting corrosion occurred in-vivo, evidenced by the damage patterns that appeared on the THR junction interfaces. There is no scientific data on the studies reporting the fretting corrosion patterns of CoCrMo microstructures in the presence of specific biological treatments to date. In the current study, Flat-on-flat fretting corrosion set-up was customized and used to study the tribocorrosion patterns of fretting corrosion to understand the role of alloy microstructure. Alloy microstructural differences were created with the implant stock metal's longitudinal and transverse cutting orientations. As a result, the transverse created the non-banded, homogenous microstructure, whereas the longitudinal cut resulted in the banded, non-homogenous microstructure on the surface of the alloy (in this manuscript, the terms homogenous and banded were used). The induced currents were monitored using a three-electrode system. Three different types of electrolytes were utilized to study the fretting corrosion patterns with both homogeneous and banded microstructures: 1. Control media 2. Spent media (the macrophage cell cultured media) 3. Challenged media (media collected after the macrophage was treated with CoCrMo particles). From the electrochemical results, in the potentiostat conditions, the banded group exhibited a higher induced current in both challenged and spent electrolyte environments than in control due to the synergistic activity of CoCrMo particles and macrophage demonstrating more corrosion loss. Additionally, both Bode and Nyquist plots reported a clear difference between the banded and homogeneous microstructure, especially with challenged electrolytes becoming more corrosion-resistant post-fretting than pre-fretting results. The banded microstructure showed a unique shape of the fretting loop, which may be due to tribochemical reactions. Therefore, from the electrochemical, mechanical, and surface analysis data results, the transverse/homogenous/non-banded alloy microstructure groups show a higher resistance to fretting-corrosion damage.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. 9 - tribological interactions of metal in total hip arthroplasty (THA)
2. Retrieval analysis of hip prostheses
3. Macrophage cytokines: involvement in immunity and infectious diseases10.3389/fimmu.2014.00491 ↗
4. Baskey · 2015
5. Lung complications after elective hip surgery10.3109/17453678208992297 ↗
6. Trunnion corrosion: what surgeons need to know in 201810.1302/0301-620X.100B1.BJJ-2017-0569.R1 ↗
7. Total hip arthroplasty: learning from both successes, failure Early improvements involved techniques, materials; current issues focus on wear debris
8. In vitro evidence for cell-accelerated corrosion within modular junctions of total hip replacements10.1002/jor.24447 ↗
9. Systemic toxicity related to metal hip prostheses10.3109/15563650.2014.944977 ↗
10. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements10.1016/j.arth.2013.02.009 ↗
11. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up10.1016/S0140-6736(18)31665-9 ↗
12. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors10.1016/j.jbiomech.2019.109424 ↗
13. 7 - fretting wear analysis through a mechanical friction energy approach: impact of contact loadings and ambient conditions
14. Retrieval analysis of large-head modular metal-on-metal hip replacements of a single design10.1016/j.arth.2017.12.044 ↗
15. Status of surface modification techniques for artificial hip implants10.1080/14686996.2016.1240575 ↗
16. Giacchia · 2011
17. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
18. Biological effects of metal degradation in hip arthroplasties10.1080/10408444.2017.1392927 ↗
19. On the design evolution of hip implants: a review10.1016/j.matdes.2022.110552 ↗
20. 2019
21. Head-neck taper corrosion in hip arthroplasty10.1155/2015/758123 ↗
22. Ten-year cross-sectional study of mechanically assisted crevice corrosion in 1352 consecutive patients with metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2017.03.020 ↗
23. Revision primary total hip replacement: causes and risk factors
24. Intergranular pitting corrosion of CoCrMo biomedical implant alloy - Panigrahi - 2014 - Journal of Biomedical Materials Research Part B: Applied Biomaterials - Wiley Online Library https://onlinelibrary.wiley.com/doi/full/10.1002/jbm.b.33067.
25. Effect of microstructures on the corrosion behavior of reinforcing bars (rebar) embedded in concrete10.1007/s12540-019-00288-1 ↗
26. Breakage of metal hip arthroplasty components: retrieval and structural analysis
27. Learmonth · 2012
28. CoCrMo metal-on-metal hip replacements10.1039/C2CP42968C ↗
29. Lightsource · 2018
30. Lin · 2012
31. Rates and outcomes of primary and revision total hip replacement in the United States medicare population10.2106/00004623-200301000-00005 ↗
32. Hip implant modular junction: the role of CoCrMo alloy microstructure on fretting-corrosion10.1016/j.jmbbm.2022.105402 ↗
33. What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?10.1016/j.jmbbm.2011.11.004 ↗
34. Are damage modes related to microstructure and material loss in severely damaged CoCrMo femoral heads?10.1097/CORR.0000000000001819 ↗
35. A high prevalence of corrosion at the head–neck taper with contemporary Zimmer non-cemented femoral hip components10.1016/j.arth.2015.02.019 ↗
36. Metal Wear Particle - an overview | ScienceDirect Topics. https://www.sciencedirect.com/topics/engineering/metal-wear-particle.
37. Metallosis. mctlaw https://www.mctlaw.com/joint-replacement/metallosis-metal-hip/.
38. Total hip arthroplasty in patients with chronic liver disease: a systematic review10.1051/sicotj/2019037 ↗
39. Alloy microstructure dictates corrosion modes in THA modular junctions10.1007/s11999-017-5486-3 ↗
40. What factors drive taper corrosion?10.1016/j.arth.2018.03.055 ↗
41. Chronology of total hip joint replacement and materials development
42. Total hip replacement in patients with neurological conditions10.1302/0301-620X.91B10.22934 ↗
43. Biomaterials in devices
44. Fretting-corrosion in hip implant modular junctions: new experimental set-up and initial outcome10.1016/j.triboint.2015.04.032 ↗
45. Fretting-corrosion behavior in hip implant modular junctions: the influence of friction energy and pH variation10.1016/j.jmbbm.2016.05.024 ↗
46. In vitro simulation of fretting-corrosion in hip implant modular junctions: the influence of pH10.1016/j.medengphy.2017.10.016 ↗
47. Ultra-high-molecular-weight polyethylene (UHMWPE) in total joint arthroplasty
48. Fretting corrosion, third-body polyethylene damage, and cup positioning in primary vs revision dual mobility total hip arthroplasty10.1016/j.arth.2021.01.035 ↗
49. Total Hip Replacement - OrthoInfo - AAOS. https://www.orthoinfo.org/en/treatment/total-hip-replacement/.
50. The metabolic signature of macrophage responses10.3389/fimmu.2019.01462 ↗
51. CoCrMo metal release in metal‐on‐highly crosslinked polyethylene hip implants10.1002/jbm.b.34470 ↗
52. The survival rates and risk factors of implants in the early stage: a retrospective study10.1186/s12903-021-01651-8 ↗
53. Effect of macrophages on in vitro corrosion behavior of magnesium alloy10.1002/jbm.a.35788 ↗
54. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner10.1302/0301-620X.95B1.30060 ↗