Abstract

Finite element analysis (FEA) is nowadays a pivotal tool in orthopaedic research for personalized virtual surgery planning. Despite its widespread use, a comprehensive evaluation of the effect of boundary conditions on the simulation of physiological mechanics in implanted bone is currently lacking. This study assesses the impact of boundary conditions and femur geometry on predicted femur mechanics. It focuses on an isolated implanted femur, partially imaged, from a paediatric patient with femoral varus who underwent a proximal femoral osteotomy. By employing FEA of the femur under motion with loading scenarios informed by personalized neuromusculoskeletal modelling, this study evaluated implant and bone mechanics across three femur model configurations (full-femur, proximal half-femur, and distally synthesized full-femur) with two boundary condition approaches (biomechanical and fixed distal). The biomechanical boundary condition was validated against the gold standard inertia relief method for the natural femur and thereafter exploited as the benchmark against the other implanted femur model configurations. The distally synthesized full-femur with biomechanical boundary conditions performed best and closely predicted bone-implant micromotion (R 2 = 0.99, nRMSE = 0.3%), risk of implant yield (<1% variance from the benchmark model), and interfragmentary movement (R 2 = 1, nRMSE = 6%). The half-femur model with biomechanical boundary conditions overpredicted the risk of yield and interfragmentary movements by 17% and 15.8%, respectively. The fixed distal constraint method significantly overestimated the risk of implant yield in both half and synthesized full-femur models by 157% and 170%, respectively. These findings underscore the critical importance of selecting appropriate boundary conditions in the FEA of implanted femur models and advocate for the synthesis of the missing portion of the femur coupled with the biomechanical boundary conditions for more accurate predictions of bone and implant mechanics. Such insights are expected to enhance the physiological plausibility and reliability of orthopaedic research and clinical practices, especially when managing proximal femoral osteotomies. • Evaluation of femur mechanics using FEA with personalized loading conditions. • Fixed distal constraints overestimate tested bone-implant mechanics. • Synthesized full-femur model with biomechanical constraints accurately predicts outcomes. • Accurate boundary conditions are critical in orthopaedic FEA. • Advocacy for the synthesis of the missing geometry with biomechanical constraints.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Hip disorders and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (58)

Show source-provided references
1. Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone10.1007/s00198-004-1728-9 ↗
2. Simulated effects of surgical corrections on bone-implant micromotion and implant stresses in paediatric proximal femoral osteotomy10.1016/j.compbiomed.2024.109544 ↗
3. Effect of postoperative Neck-Shaft and anteversion angles on biomechanical outcomes in proximal femoral osteotomy: An in silico study10.1002/jor.26043 ↗
4. Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait10.1038/s41598-024-61305-x ↗
5. Influence of femur size and morphology on load transfer in the resurfaced femoral head: a large scale, multi-subject finite element study10.1016/j.jbiomech.2012.05.015 ↗
6. Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis10.1016/j.clinbiomech.2003.12.003 ↗
7. Comparative study of femur bone having different boundary conditions and bone structure using finite element method10.2174/1874120701812010115 ↗
8. Patient-specific finite element analysis for assessing hip fracture risk in aging populations
9. 2022
10. Sensitivity analysis of paediatric knee kinematics to the graft surgical parameters during anterior cruciate ligament reconstruction: a sequentially linked neuromusculoskeletal-finite element analysis10.1016/j.cmpb.2024.108132 ↗
11. OpenSim: open-source software to create and analyze dynamic simulations of movement10.1109/TBME.2007.901024 ↗
12. A deep learning-based approach to automatic proximal femur segmentation in quantitative CT images10.1007/s11517-022-02529-9 ↗
13. Can 3D surgical planning and patient specific instrumentation reduce hip implant inventory? A prospective study10.1186/s41205-020-00077-2 ↗
14. A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests10.1243/09544119JEIM799 ↗
15. Enhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: a neuromusculoskeletal-informed finite element analysis10.1016/j.cmpb.2024.108480 ↗
16. Biomechanical factors that influence the bone-implant-interface
17. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses
18. Material mapping strategy to improve the predicted response of the proximal femur to a sideways fall impact10.1016/j.jmbbm.2017.10.033 ↗
19. Femur/stature ratio and estimates of stature in children10.1002/ajpa.1330870406 ↗
20. Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis10.1016/S0268-0033(02)00012-8 ↗
21. Subject-specific FE models of the human femur predict fracture path and bone strength under single-leg-stance loading10.1016/j.jmbbm.2020.104118 ↗
22. Relationships of 35 lower limb muscles to height and body mass quantified using MRI10.1016/j.jbiomech.2013.12.002 ↗
23. Development of recommendations for SEMG sensors and sensor placement procedures10.1016/S1050-6411(00)00027-4 ↗
24. Letter to the editor regarding "Effect of low pass filtering on joint moments from inverse dynamics: implications for injury prevention"10.1016/j.jbiomech.2012.02.028 ↗
25. Selecting boundary conditions in physiological strain analysis of the femur: balanced loads, inertia relief method and follower load10.1016/j.medengphy.2015.10.002 ↗
26. The number of screws, bone quality, and friction coefficient affect acetabular cup stability10.1016/j.medengphy.2006.11.005 ↗
27. Reliability of four models for clinical gait analysis10.1016/j.gaitpost.2017.04.001 ↗
28. Validation and evaluation of subject-specific finite element models of the pediatric knee10.1038/s41598-023-45408-5 ↗
29. Development and validation of statistical models of femur geometry for use with parametric finite element models10.1007/s10439-015-1307-6 ↗
30. The limit of tolerable micromotion for implant osseointegration: a systematic review10.1038/s41598-021-90142-5 ↗
31. Biomechanical effect of different femoral neck blade position on the fixation of intertrochanteric fracture: a finite element analysis10.1515/bmt-2015-0091 ↗
32. Developing CT based computational models of pediatric femurs10.1016/j.jbiomech.2015.03.027 ↗
33. When medical images meet generative adversarial network: recent development and research opportunities10.1007/s44163-021-00006-0 ↗
34. MOtoNMS: a MATLAB toolbox to process motion data for neuromusculoskeletal modeling and simulation10.1186/s13029-015-0044-4 ↗
35. Bone remodelling in implanted proximal femur using topology optimization and parameterized cellular model10.1016/j.jmbbm.2021.104903 ↗
36. Estimation of musculotendon parameters for scaled and subject specific musculoskeletal models using an optimization technique10.1016/j.jbiomech.2015.11.006 ↗
37. Analysis of stress distribution around total hip stems custom-designed for the standardized Asian femur configuration10.1080/13102818.2014.928450 ↗
38. Comparison of the properties of additively manufactured 316L stainless steel for orthopedic applications: a review
39. The primary stability of a cementless stem varies between subjects as much as between activities10.1016/S0021-9290(03)00011-3 ↗
40. CEINMS: a toolbox to investigate the influence of different neural control solutions on the prediction of muscle excitation and joint moments during dynamic motor tasks10.1016/j.jbiomech.2015.09.021 ↗
41. Full-body musculoskeletal model for muscle-driven simulation of human gait10.1109/TBME.2016.2586891 ↗
42. Ratner · 2004
43. EMG-driven forward-dynamic estimation of muscle force and joint moment about multiple degrees of freedom in the human lower extremity10.1371/journal.pone.0052618 ↗
44. Hybrid neuromusculoskeletal modeling to best track joint moments using a balance between muscle excitations derived from electromyograms and optimization10.1016/j.jbiomech.2014.10.009 ↗
45. Impact of increased body mass index on orthopaedic trauma implantology
46. Physiologically based boundary conditions in finite element modelling10.1016/j.jbiomech.2006.10.038 ↗
47. Minimal medical imaging can accurately reconstruct geometric bone models for musculoskeletal models10.1371/journal.pone.0205628 ↗
48. Experimental versus computational analysis of micromotions at the implant—bone interface10.1243/09544119JEIM825 ↗
49. Stress and strain distribution within the intact femur: compression or bending?10.1016/1350-4533(95)00031-3 ↗
50. Modeling the musculoskeletal loading in bone remodeling at the hip of a child10.1016/j.cmpb.2021.106365 ↗
51. Stress and strain distribution in femoral heads for hip resurfacing arthroplasty with different materials: a finite element analysis10.1016/j.jmbbm.2020.104115 ↗
52. Free-free dynamic systems, inertia relief
53. Winter · 2009
54. Statistical model-based segmentation of the proximal femur in digital antero-posterior (AP) pelvic radiographs10.1007/s11548-013-0932-5 ↗
55. Effects of bone mineral density at the lateral sclerotic boundary on the femoral head collapse onset in osteonecrosis of the femoral head: a preliminary study10.1016/j.clinbiomech.2023.106156 ↗
56. Partial femoral head replacement: a new innovative hip-preserving approach for treating osteonecrosis of the femoral head and its finite element analysis
57. Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations10.1016/j.jbiomech.2007.06.017 ↗
58. Accuracy of femur reconstruction from sparse geometric data using a statistical shape model10.1080/10255842.2016.1263301 ↗