How does prestrain in the tympanic membrane affect middle-ear function? A finite-element model study in rabbit
Source abstract
Abstract
Experiments have shown that prestrain exists in the rabbit tympanic membrane (TM), also in the absence of external loads. To date, it is unclear how prestrain influences the vibration response of the middle ear (ME). In this study, a detailed 3D finite-element model of the rabbit ME was constructed based on experimentally validated material properties. The model incorporates different degrees of prestrain in the TM and simulates the ME vibration response to sound as a linear harmonic perturbation around the prestressed reference state. To account for finite deformations associated with large prestrains, a framework was developed that iteratively updates the initial unstrained geometry until the prestrained geometry is in agreement with the given reference geometry. After validating the model using quasi-static and acoustic measurement data, it was shown that small levels of prestrain already have a substantial impact on the normal umbo and footplate response due to a phenomenon known as prestress stiffening. Although the approach is not preferable, it was possible to replicate the effect of prestrain in the normal ME by appropriately scaling the elastic moduli and damping factors in the base model. To evaluate the effect of possible changes in TM prestrain when the normal state of the ear is altered due to pathological modifications in the ME structure, we created a model with a perforation in the TM. It was shown that the change in vibration response after perforation is affected at low frequencies by a release of TM prestrain. In future studies, it may be necessary to incorporate prestrain in ME models to better understand the function of the diseased or reconstructed ME, which may be relevant for the development of reconstructive tissue grafts in the middle ear.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ear Surgery and Otitis Media · Acoustic Wave Phenomena Research · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Assessing the use of the "opening angle method" to enforce residual stresses in patient-specific arteries10.1007/s10439-007-9352-4 ↗
2. Perspectives on biological growth and remodeling10.1016/j.jmps.2010.12.011 ↗
3. A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vessels10.1016/j.cam.2012.10.034 ↗
4. Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures10.1007/s10162-011-0281-4 ↗
5. Analysis of the mechanical properties of the human tympanic membrane and its influence on the dynamic behaviour of the human hearing system10.1155/2018/1736957 ↗
6. A finite element approach for large strains of nearly incompressible rubber-like materials10.1016/0020-7683(79)90073-8 ↗
7. Visoelastic properties of human tympanic membrane10.1007/s10439-006-9227-0 ↗
8. Comparative histology of the tympanic membrane and its relationship to cholesteatoma10.1177/000348948909801002 ↗
9. Effects of model definitions and parameter values in finite element modeling of human middle ear mechanics10.1016/j.heares.2016.11.011 ↗
10. Effect of middle ear components on eardrum quasi-static deformation10.1016/S0378-5955(01)00290-8 ↗
11. Recherches sur la structure de la membrane du tympan chez les différents vertébrés10.1159/000140387 ↗
12. A critical review of experimental observations on ear-drum structure and function
13. Mechanical properties of stapedial annular ligament10.1016/j.medengphy.2010.10.022 ↗
14. A computational strategy for prestressing patient-specific biomechanical problems under finite deformation10.1002/cnm.1236 ↗
15. Strain distribution in rabbit eardrums under static pressure10.1016/j.heares.2019.107772 ↗
16. Effect of malleus handle fracture on middle ear sound transmission: laser Doppler vibrometry measurements and finite element simulations
17. A forward incremental prestressing method with application to inverse parameter estimations and eye-specific simulations of posterior scleral shells10.1080/10255842.2011.641119 ↗
18. What middle ear parameters tell about impedance matching and high frequency hearing10.1016/0378-5955(95)00031-X ↗
19. Modeling of the incudo-malleolar joint within a biomechanical model of the human ear10.1007/s11044-016-9550-7 ↗
20. Kirikae · 1960
21. Tympanic membrane part II.: pars flaccida10.3109/00016486809126316 ↗
22. Prestrain in the rabbit eardrum measured by digital image correlation and micro-incisions10.1016/j.heares.2021.108392 ↗
23. A general framework for application of prestrain to computational model of biological materials10.1016/j.jmbbm.2016.04.012 ↗
24. Finite-element modelling of the response of the gerbil middle ear to sound10.1007/s10162-015-0531-y ↗
25. Energy localization and frequency analysis in the locust ear10.1098/rsif.2013.0857 ↗
26. The loss-factor of pre-stressed laminated curved panels and cylinders using a wave and finite element method10.1016/j.jsv.2012.09.039 ↗
27. Postnatal development of the middle ear in New Zealand white rabbits: ossicles and tympanic ring10.1016/j.heares.2010.10.005 ↗
28. HECTOR: a 240 kV micro-CT setup optimized for research10.1088/1742-6596/463/1/012012 ↗
29. Finite element analysis of sinusoidal small-amplitude vibrations in deformed viscoelastic solids. Part I: theoretical development10.1002/nme.1620190712 ↗
30. A non-linear viscoelastic model for the tympanic membrane10.1121/1.4828831 ↗
31. Structural stiffening in the human middle ear due to static pressure: finite-element analysis of combined static and dynamic middle-ear behavior10.1016/j.heares.2020.108116 ↗
32. Review of methods for determining residual stresses in biological materials
33. Experimental methods for determining residual stresses and strains in various biological structures10.1007/s11340-013-9806-6 ↗
34. The effects of varying tympanic-membrane material properties on human middle-ear sound transmission in a three-dimensional finite-element model10.1121/1.5008741 ↗
35. Nonlinear vibration response measured at umbo and stapes in the rabbit middle ear10.1007/s10162-015-0535-7 ↗
36. A method for incorporating three-dimensional residual stretches/stresses into patient-specific finite element simulations of arteries10.1016/j.jmbbm.2015.03.024 ↗
37. Constrained layer damping of initially stressed composite beams using finite elements10.1177/002199839202601204 ↗
38. On the effect of prestrain and residual stress in biological membranes10.1016/j.jmps.2013.04.005 ↗
39. Soft tissue morphometry of the malleus–incus complex from micro-CT imaging10.1007/s10162-007-0103-x ↗
40. Elasticity modulus of rabbit middle ear ossicles determined by a novel micro-indentation technique10.1016/j.heares.2009.10.001 ↗
41. Finite element analysis of the effect of actuator coupling conditions on round window stimulation10.1142/S0219519415500487 ↗
42. The structure of the middle ear and the hearing of one's own voice by bone conduction10.1121/1.1906501 ↗
43. Middle-ear function with tympanic-membrane perforations. I. Measurements and mechanisms10.1121/1.1394195 ↗
44. A generalized prestressing algorithm for finite element simulations of preloaded geometries with application to the aorta10.1002/cnm.2632 ↗
45. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint10.1007/s10237-010-0268-9 ↗
46. Assigning viscoelastic and hyperelastic properties to the middle-ear soft tissues for sound transmission10.1007/s10237-019-01263-w ↗