Global stiffness and residual stresses in spinal fixator systems: A validated finite element study on the interconnection mechanism
Source abstract
Abstract
Posterior spinal fixation systems are the gold standard to treat different column disorders using rods and screws. The proper connection between them is guaranteed by the Interconnection Mechanism (IM), consisting of different metallic subcomponents held together through the application of tightening torque. The response of the fixation system is defined by its overall stiffness, which in turn is governed by the local residual stress field arising during tightening. Although literature computational models for studying spinal fixation are becoming increasingly anatomically complex, most studies disregard completely the realistic modeling of the IM, namely choosing elastic-plastic material models and proper contact interactions. In this frame, the present study aims at increasing awareness in the field of spinal fixation modeling by investigating the mechanical response of the IM in terms of overall stiffness and local residual stresses. Once validated through dedicated experiments, the results of the proposed model have been compared with the current literature, highlighting the key role of the IM in the reliable modeling of spinal fixation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Orthopaedic implants and arthroplasty · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Comparison of rod fracture rates in long spinal deformity constructs after transforaminal versus anterior lumbar interbody fusions: a single-institution analysis
2. Simple technique for removing broken pedicular screws10.5704/MOJ.1403.003 ↗
3. Biomechanical evaluation of segmental pedicle screw fixation in thoracolumbar fracture: a finite element study
4. Impact of electrocautery on fatigue life of spinal fusion constructs-An in vitro biomechanical study10.3390/ma12152471 ↗
5. 2021
6. Three cases of metallosis associated with spine instrumentation10.1007/s10856-017-6011-7 ↗
7. Barocas · Mechanical Perform. Posterior Spinal · 2019 · 44 · 1270
8. Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series10.1186/s13013-015-0056-5 ↗
9. Residual stresses in titanium spinal rods: effects of two contouring methods and material plastic properties10.1115/1.4040451 ↗
10. Incomplete insertion of pedicle screws in a standard construct reduces the fatigue life: a biomechanical analysis10.1371/journal.pone.0224699 ↗
11. Rod fracture after apparently solid radiographic fusion in adult spinal deformity patients10.1016/j.wneu.2018.06.071 ↗
12. Implications of spine fixation on the adjacent lumbar levels for surgical treatment of thoracolumbar burst fractures: a finite element analysis10.15761/JSC.1000105 ↗
13. A finite element study on the treatment of thoracolumbar fracture with a new spinal fixation system
14. Biomechanical evaluation of the effects of implant neckwall thickness and abutment screw size: a 3D nonlinear finite element analysis10.3390/app10103471 ↗
15. Evaluation of tribological properties and condition of TI6AL4V titanium alloy surface
16. Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy10.1007/s00586-018-5623-z ↗
17. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?10.1177/0954411914554244 ↗
18. Preclinical evaluation of posterior spine stabilization devices: can we compare in vitro and in vivo loads on the instrumentation?10.1007/s00586-016-4766-z ↗
19. Preclinical evaluation of posterior spine stabilization devices: can the current standards represent basic everyday life activities?10.1007/s00586-016-4622-1 ↗
20. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 1218910.1016/j.spinee.2015.07.461 ↗
21. Toward the definition of a new worst-case paradigm for the preclinical evaluation of posterior spine stabilization devices10.1177/0954411916684365 ↗
22. Biomechanical in vitro comparison between anterior column realignment and pedicle subtraction osteotomy for severe sagittal imbalance correction10.1007/s00586-019-06087-x ↗
23. Finite element analysis to determine implant preload10.1016/j.prosdent.2003.09.012 ↗
24. Rod fracture in adult spinal deformity surgery fused to the sacrum: prevalence, risk factors, and impact on health-related quality of life in 526 patients10.1016/j.spinee.2018.02.008 ↗
25. The effects of rod contouring on spinal construct fatigue strength10.1097/01.brs.0000224177.97846.00 ↗
26. Screws fixation for oblique lateral lumbar interbody fusion (OL-LIF): a finite element study10.1155/2021/5542595 ↗
27. Biomechanical investigation between rigid and semirigid posterolateral fixation during daily activities: geometrically parametric poroelastic finite element analyses
28. Rod fracture and related factors after total en bloc spondylectomy10.1016/j.spinee.2019.04.018 ↗
29. Mechanical performance of thoracolumbosacral pedicle screw systems: an analysis of data submitted to the Food and Drug Administration10.1016/j.jbiomech.2021.110551 ↗
30. Computational and experimental fatigue analysis of contoured spinal rods10.1115/1.4042767 ↗
31. The effect of contouring on fatigue strength of spinal rods: is it okay to re-bend and which materials are best?10.1016/j.jspd.2013.08.004 ↗
32. Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity10.1227/NEU.0b013e3182672aab ↗
33. Trautwein · 2016
34. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems10.1016/j.spinee.2013.08.032 ↗
35. Development of a three-dimensional finite element model of thoracolumbar kyphotic deformity following vertebral column decancellation10.1155/2019/5109285 ↗
36. Research on friction properties of titanium alloy surface microstructure substrate titanium dioxide films
37. Zhao · 2018 · vol. 97