journal article·2024-02Open access

Effect of the apron in the mechanical characterisation of hyperelastic materials by means of biaxial testing: A new method to improve accuracy

Sofia Di Leonardo, Alessandra Monteleone, Patrizia Caruso, Hugo Meecham-Garcia, Giuseppe Pitarresi, Gaetano Burriesci

Abstract

Biological soft tissues and polymers used in biomedical applications (e.g. in the cardiovascular area) are hyperelastic incompressible materials that commonly operate under multi-axial large deformation fields. Their characterisation requires biaxial tensile testing. Due to the typically small sample size, the gripping of the specimens commonly relies on rakes or sutures, where the specimen is punctured at the edges of the gauge area. This approach necessitates of an apron, excess of material around the gauge region. This work analyses the apron influence on the estimated mechanical response of biaxial tests performed by using a rakes gripping system, with the aim of verifying the test accuracy and propose improved solutions. In order to isolate the effect of the apron, avoiding the influence of anisotropy and inhomogeneity typical of most soft tissues, homogeneous and isotropic hyperplastic samples made from a uniform sheet of casted silicone were tested. The stress-strain response of specimens with different apron sizes/shapes was measured experimentally by means of biaxial testing and digital image correlation. Tests were replicated numerically, to interpret the experimental findings. The apron surrounding the gauge area acts as an additional annular constraint which stiffens the system, resulting in a significant overestimate in the stress values. This error can be avoided by introducing specific cuts in the apron. The study quantifies, for the first time, the correlation between the apron size/shape and the experimental stress overestimation, proposing a research protocol which, although identified on homogeneous hyperelastic materials, can be useful in providing more accurate characterisation of both, synthetic polymers and soft tissues.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Elasticity and Material Modeling · Cardiac Valve Diseases and Treatments · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (66)

Show source-provided references
1. Engineering approaches for characterizing soft tissue mechanical properties: a review10.1016/j.clinbiomech.2019.07.016 ↗
2. A review of constitutive models for rubber-like materials10.3844/ajeassp.2010.232.239 ↗
3. Amin, A.F., Wiraguna, S.I., Bhuiyan, A.R., Okui, Y., 2006. Hyperelasticity model for finite element analysis of atural and high damping rubbers in compression and shear. J. Eng. Mech. 132, 54–64.doi:10.1061/(ASCE)0733-9399(2006)132:1(54).10.1061/(ASCE)0733-9399(2006)132:1(54) ↗
4. A three-dimensional constitutive model for the large stretch behavior of rubber elastic materials10.1016/0022-5096(93)90013-6 ↗
5. Pertinence of sheep knee joint for calibration of ligaments’ constitutive equations; experimental and theoretical study
6. Integrated experimental and numerical comparison of different approaches for planar biaxial testing of a hyperelastic material10.1155/2016/6014129 ↗
7. NuMED covered cheatham-platinum stentTM for the treatment or prevention of right ventricular outflow tract conduit disruption during transcatheter pulmonary valve replacement, Catheter10.1002/ccd.25682 ↗
8. Ncorr: open-source 2D digital image correlation matlab software10.1007/s11340-015-0009-1 ↗
9. The evolution of device technology in transcatheter aortic valve implantation10.4244/EIJ-D-18-01048 ↗
10. Design of a novel polymeric heart valve10.3109/03091900903261241 ↗
11. A review of methods to characterize rubber elastic behavior for use in finite element analysis10.5254/1.3538686 ↗
12. Cowin · 2001 · 259
13. The role of pre-conditioning frequency in the experimental characterization of hyper-elastic materials as models for soft tissue applications10.1142/S1758825116500666 ↗
14. Review of experimental investigations on compressibility of arteries and introduction of a new apparatus10.1007/s11340-012-9614-4 ↗
15. Strain uniformity in biaxial specimens is highly sensitive to attachment details10.1115/1.3148467 ↗
16. Valve strain quantitation in normal mitral valves and mitral prolapse with variable degrees of regurgitation10.1016/j.jcmg.2021.01.006 ↗
17. Planar biaxial testing of soft biological tissue using rakes: a critical analysis of protocol and fitting process10.1016/j.jmbbm.2016.01.011 ↗
18. Biomechanics: mechanical properties of living tissues10.1115/1.2901550 ↗
19. Preliminary implantation of a novel TAVR device with polymeric leaflets for symptomatic calcific aortic disease10.1016/j.jaccas.2023.101901 ↗
20. Polymeric heart valves: new materials, emerging hopes10.1016/j.tibtech.2009.03.002 ↗
21. Proximal aorta longitudinal strain predicts aortic root dilation rate and aortic events in Marfan syndrome10.1093/eurheartj/ehz191 ↗
22. Analysis of passive cardiac constitutive laws for parameter estimation using 3D tagged MRI10.1007/s10237-014-0638-9 ↗
23. An isotropic hyperelastic model of esophagus tissue layers along with three-dimensional simulation of esophageal peristaltic behavior
24. Basic studies in biaxial tensile tests10.1002/gamm.201800004 ↗
25. Holzapfel · 2008 · 285
26. Constitutive modelling of passive myocardium: a structurally based framework for material characterization10.1098/rsta.2009.0091 ↗
27. Histologic and ultrastructural features of normal human parietal pericardium10.1016/0002-9149(80)90424-5 ↗
28. Micromechanical poroelastic and viscoelastic properties of ex-vivo soft tissues10.1016/j.jbiomech.2020.110090 ↗
29. Biomechanical properties and microstructure of heart chambers: a paired comparison study in an ovine model10.1007/s10439-016-1658-7 ↗
30. A versatile biaxial testing platform for soft tissues10.1016/j.jmbbm.2020.104144 ↗
31. A comparison among Neo-Hookean model, Mooney-Rivlin model, and Ogden model for chloroprene rubber10.1007/s12541-012-0099-y ↗
32. Experimental testing and constitutive modeling of the mechanical properties of the swine skin tissue
33. New perspectives on the thrombotic complications of haemolysis10.1111/bjh.13183 ↗
34. Shape optimisation of a biaxially loaded cruciform specimen10.1016/j.polymertesting.2009.11.004 ↗
35. A comparative study of several material models for prediction of hyperelastic properties: application to silicone-rubber and soft tissues10.1111/j.1475-1305.2006.00257.x ↗
36. IV. On the dynamical theory of gases
37. Biomechanics of soft tissues
38. A theory of large elastic deformation10.1063/1.1712836 ↗
39. 2000
40. 2016 · 82
41. Characterization of mechanical properties of pericardium tissue using planar biaxial tension and flexural deformation10.1016/j.jmbbm.2017.08.039 ↗
42. The role of patient-specific morphological features of the left atrial appendage on the thromboembolic risk under atrial fibrillation10.3389/fcvm.2022.894187 ↗
43. Large deformation isotropic elasticity – on the correlation of theory and experiment for incompressible rubberlike solids
44. 1-Year patency of biorestorative polymeric coronary artery bypass grafts in an ovine model, JACC basic to transl
45. Development of novel synthetic muscle tissues for sports impact surrogates10.1016/j.jmbbm.2014.08.011 ↗
46. Generalized anisotropic inverse mechanics for soft tissues10.1115/1.4001257 ↗
47. Identification of regional mechanical anisotropy in soft tissue analogs10.1115/1.4005170 ↗
48. Valves, Polymeric: Biocompatibility10.1081/E-EBPP-120051067 ↗
49. Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer10.1016/j.jbiomech.2012.01.046 ↗
50. Large elastic deformations of isotropic materials
51. Characterizing the non-linear mechanical behavior of native and biomimetic engineered tissues in 1D with physically meaningful parameters10.1016/j.jmbbm.2019.103509 ↗
52. Biaxial mechanical evaluation of planar biological materials10.1023/A:1010917028671 ↗
53. On the biomechanics of heart valve function10.1016/j.jbiomech.2009.05.015 ↗
54. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement10.1186/s12872-018-0818-0 ↗
55. Fascial plasticity – a new neurobiological explanation: Part 110.1016/S1360-8592(02)00067-0 ↗
56. The uniaxial stress versus strain response of pig skin and silicone rubber at low and high strain rates10.1016/j.ijimpeng.2004.11.010 ↗
57. Shitikova · 2022 · 285
58. Impaired aortic strain and distensibility by cardiac MRI in children with chronic kidney disease10.1038/s41598-022-15017-9 ↗
59. Assessment of the aortic stress-strain relation in uniaxial tension10.1016/S0021-9290(02)00073-8 ↗
60. Standard · 1995
61. Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues10.1115/1.1933931 ↗
62. Susan · 2015
63. Sutton · 2009
64. Development and realization of an experimental bench test for synchronized small angle light scattering and biaxial traction analysis of tissues
65. Boundary conditions during biaxial testing of planar connective tissues: Part II. Fiber orientation10.1023/A:1016576603938 ↗
66. Isotropic incompressible hyperelastic models for modelling the mechanical behaviour of biological tissues: a review