TiNbSn alloy plates with low Young's modulus modulates interfragmentary movement and promote osteosynthesis in rat femur
Source abstract
Abstract
Orthopedic implants such as arthroplasty prostheses, fracture plates, and intramedullary nails often use materials like Ti6Al4V alloy and commercially pure titanium (CP-Ti), which have Young's modulus significantly higher than that of human cortical bone, potentially causing stress shielding and inhibiting effective fracture healing. TiNbSn alloy, a β-type titanium alloy with a lower Young's modulus (40–49 GPa), has shown promise in reducing stress shielding and enhancing bone healing by promoting effective load sharing with bone. This study used 5-hole plates made from TiNbSn alloy and CP-Ti to investigate their effects on bone healing in a rat femoral fracture model. Micro-CT analysis and mechanical testing were performed six weeks postoperatively to assess bone healing. Additionally, Finite element method (FEM) analysis was employed to evaluate stress shielding and interfragmentary movement (IFM) at the fracture site. Micro-CT analysis revealed significantly higher bone volume and mineral density in the TiNbSn group than in the CP-Ti group. Mechanical testing showed increased maximum load and stiffness in the TiNbSn group (77.2 ± 10.0 N for the TiNbSn alloy plate group versus 53.3 ± 8.5 N for the CP-Ti group (p = 0.002)). FEM analysis indicated that TiNbSn plates reduced stress shielding and allowed for greater displacement and strain, promoting IFM conducive to bone healing. The findings suggest that TiNbSn alloy plates are more effective than CP-Ti plates in promoting bone healing by reducing stress shielding and enhancing IFM. The lower Young's modulus of TiNbSn allows better load distribution, facilitating bone regeneration and strengthening at the fracture site. • The study found that the TiNbSn alloy, with a lower Young's modulus (40–49 GPa), effectively reduces stress shielding compared to conventional CP-Ti. This reduction allows for better load sharing between the implant and bone, which supports bone healing. • TiNbSn alloy plates were shown to promote bone healing more effectively than CP-Ti plates. Micro-CT analysis and mechanical testing evidenced that the TiNbSn plates resulted in greater bone volume, bone mineral density, and new bone formation. • Finite element analysis suggested that the TiNbSn alloy plates may provide appropriate interfragmentary movement (IFM), a critical factor for promoting bone formation and angiogenesis. This suggests a potential for improved clinical outcomes in fracture healing compared to conventional materials.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone fractures and treatments · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Accuracy of beam theory for estimating bone tissue modulus and yield stress from 3-point bending tests on rat femora10.1016/j.jbiomech.2020.109654 ↗
2. Shear movement at the fracture site delays healing in a diaphyseal fracture model10.1016/S0736-0266(03)00098-6 ↗
3. TiNbSn stems with gradient changes of Young's modulus and stiffness reduce stress shielding compared to the standard fit-and-fill stems10.1186/s40001-023-01199-z ↗
4. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
5. Mid-term results of a new femoral prosthesis using Ti-Nb-Sn alloy with low Young's modulus10.1186/s12891-021-04879-1 ↗
6. A novel method for lateral callus distraction and its importance for the mechano-biology of bone formation10.1016/j.bone.2010.07.010 ↗
7. The mode of interfragmentary movement affects bone formation and revascularization after callus distraction10.1371/journal.pone.0202702 ↗
8. The concept of locking plates10.1016/j.otsr.2010.03.008 ↗
9. DLS 5.0--the biomechanical effects of dynamic locking screws10.1371/journal.pone.0091933 ↗
10. Validation of a femoral critical size defect model for orthotopic evaluation of bone healing: a biomechanical, veterinary and trauma surgical perspective10.1089/tec.2007.0234 ↗
11. Biomechanics of locked plates and screws10.1097/00005131-200409000-00003 ↗
12. Biomechanical evaluation of different strain judging criteria on the prediction precision of cortical bone fracture simulation under compression10.3389/fbioe.2023.1168783 ↗
13. Effects of intramedullary nails composed of a new beta-type Ti-Nb-Sn alloy with low Young's modulus on fracture healing in mouse tibiae10.1002/jbm.b.34064 ↗
14. Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots10.1016/j.injury.2010.02.022 ↗
15. New femoral designs: do they influence stress shielding?10.1097/01.blo.0000246541.41951.20 ↗
16. The influence of induced micromovement upon the healing of experimental tibial fractures10.1302/0301-620X.67B4.4030869 ↗
17. Octacalcium phosphate/gelatin composite (OCP/gel) enhances bone repair in a critical-sized transcortical femoral defect rat model10.1097/CORR.0000000000002257 ↗
18. A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion10.1007/s11517-012-0986-5 ↗
19. A robust 3D finite element simulation of human proximal femur progressive fracture under stance load with experimental validation10.1007/s10439-013-0864-9 ↗
20. Research and development of βTi alloy stems for artificial hip joint10.2320/materia.60.697 ↗
21. Effect of stress-induced α″ martensite on Young's modulus of β Ti–33.6Nb–4Sn alloy10.1016/j.msea.2013.09.053 ↗
22. Fabrication of a high-performance hip prosthetic stem using beta Ti-33.6Nb-4Sn10.1016/j.jmbbm.2013.11.002 ↗
23. Comparison of biophysical stimuli for mechano-regulation of tissue differentiation during fracture healing10.1016/j.jbiomech.2005.01.037 ↗
24. Beta-type TiNbSn alloy plates with low Young modulus accelerates osteosynthesis in rabbit tibiae10.1097/CORR.0000000000002240 ↗
25. Mechanical properties and microstructures of beta Ti-25Nb-11Sn ternary alloy for biomedical applications10.1016/j.msec.2012.12.072 ↗
26. Low Young's modulus TiNbSn alloy locking plates accelerate osteosynthesis in rabbit tibiae10.1620/tjem.2023.J075 ↗
27. Effects of elastic intramedullary nails composed of low Young's modulus Ti-Nb-Sn alloy on healing of tibial osteotomies in rabbits10.1002/jbm.b.34163 ↗
28. Human parathyroid hormone (1-34) accelerates the fracture healing process of woven to lamellar bone replacement and new cortical shell formation in rat femora10.1016/j.bone.2005.02.002 ↗
29. Improved osseointegration of a TiNbSn alloy with a low Young's modulus treated with anodic oxidation10.1038/s41598-019-50581-7 ↗
30. Antibacterial activity of an anodized TiNbSn alloy prepared in sodium tartrate electrolyte10.3389/fbioe.2022.883335 ↗
31. Initial vascularization and tissue differentiation are influenced by fixation stability10.1016/j.orthres.2004.09.006 ↗
32. Bioactive TiNbSn alloy prepared by anodization in sulfuric acid electrolytes10.1016/j.msec.2019.01.033 ↗
33. Photoactivity of an anodized biocompatible TiNbSn alloy prepared in sodium tartrate/hydrogen peroxide aqueous solution10.1016/j.apsusc.2020.148829 ↗
34. Photoinduced properties of anodized Ti alloys for biomaterial applications10.1038/s41598-023-41189-z ↗
35. Beta TiNbSn alloys with low young's modulus and high strength10.2320/matertrans.46.1070 ↗
36. Three-dimensional printable metamaterial intramedullary nails with tunable strain for the treatment of long bone fractures10.1016/j.matdes.2022.110942 ↗
37. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus10.1016/j.actbio.2011.02.008 ↗
38. Acceleration of fracture healing in mouse tibiae using intramedullary nails composed of beta-type TiNbSn alloy with low Young's modulus10.1620/tjem.255.135 ↗
39. A review of anodized TiNbSn alloys for improvement in layer quality and application to orthopedic implants10.3390/ma15155116 ↗
40. Antimicrobial properties of TiNbSn alloys anodized in a sulfuric acid electrolyte10.3390/ma16041487 ↗
41. A review of the impacts of implant stiffness on fracture healing10.3390/app14062259 ↗
42. Impact of simultaneous hydrolysis of OCP and PLGA on bone induction of a PLGA-OCP composite scaffold in a rat femoral defect10.1016/j.actbio.2021.01.048 ↗
43. Intramembranous bone formation after callus distraction is augmented by increasing axial compressive strain10.1371/journal.pone.0195466 ↗
44. Variable-node plate and shell elements with assumed natural strain and smoothed integration methods for nonmatching meshes10.1007/s00466-012-0774-y ↗
45. Experiment study on fracture fixation with low rigidity titanium alloy: plate fixation of tibia fracture model in rabbit10.1007/s10856-008-3372-y ↗
46. Apatite Formation and biocompatibility of a low Young's modulus Ti-Nb-Sn alloy treated with anodic oxidation and hot water10.1371/journal.pone.0150081 ↗
47. Internal plate fixation of fractures: short history and recent developments10.1007/s00776-005-0984-7 ↗
48. Effects of strain artefacts arising from a pre-defined callus domain in models of bone healing mechanobiology10.1007/s10237-015-0659-z ↗
49. Improving stress shielding following total hip arthroplasty by using a femoral stem made of beta type Ti-33.6Nb-4Sn with a Young's modulus gradation10.1016/j.jbiomech.2017.08.017 ↗
50. Finite element modeling of proximal femur with quantifiable weight-bearing area in standing position10.1186/s13018-020-01927-9 ↗