Biomechanical behavior of cantilevered 3-unit implant-supported prostheses made of PEKK and monolithic zirconia: A finite element study
Source abstract
Abstract
OBJECTIVE: To evaluate the biomechanical performance of various designs of cantilevered three-unit implant-supported prostheses, using two distinct prosthetic materials and under different loading conditions. METHOD: Three mandibular models were created with varying implant positions to support a 3-unit prosthesis using two materials (Zirconia and PEKK), resulting in three different designs: distal cantilever (M1), fixed-fixed (M2), and mesial cantilever (M3). The geometric model was created by segmenting a CBCT scan of an edentulous mandible using Mimics software, followed by refinement in 3-Matic to generate a trabecular bone core encased by a 2 mm-thick cortical shell and a 1 mm-thick mucosal layer. Implant CAD files were integrated, and the models were processed in SolidWorks to finalize solid geometries. These were then imported into ANSYS for mesh generation and finite element analysis, with materials assumed to be isotropic and elastic. Models underwent 3 different static loading protocols (Vertical 100 N, 30° Oblique 50 N, 45° Oblique 50 N). Von Mises stress and total deformation were calculated. RESULTS: Model 2 demonstrated the best performance. Under vertical loading, PEKK prostheses showed lower stress than zirconia in the prosthetic body (10-45 %) and the cortical bone (3-40 %), but higher stresses in the implant (4-10 %). Compared to vertical loading, oblique loading generated higher stress but remained within a safe range without compromising function. CONCLUSION: The fixed-fixed design showed optimal biomechanical performance. The mesial cantilever was more favorable than the distal for stress distribution. Zirconia provided superior stress dissipation, while PEKK showed reduced stress in the prosthetic body but increased stress I the implant and bone. CLINICAL SIGNIFICANCE: The study provides prosthodontists with evidence recommending design and materials for 3-unit implant-supported prostheses. Zirconia is ideal for cantilevered designs, resisting high bending forces and minimizing implant stress, while PEKK is more suitable for fixed-fixed designs with lower stress levels.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Scientific and Engineering Research Topics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Abaza · 2023 · vol. 3
2. Biomechanical behavior of implant retained prostheses in the posterior maxilla using different materials: a finite element study10.1186/s12903-024-04142-8 ↗
3. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years10.1111/j.1600-0501.2009.01706.x ↗
4. Clinical and radiographic changes at implants supporting single-unit crowns (SCs) and fixed dental prostheses (FDPs) with one cantilever extension. A retrospective study10.1111/j.1600-0501.2011.02391.x ↗
5. Rehabilitation of edentulous jaws with full-arch fixed implant-supported prostheses: an approach with short and ultrashort implants and metal-free materials
6. Recent advances in material and geometrical modelling in dental applications10.3889/oamjms.2018.254 ↗
7. Stress analysis around reduced-diameter zirconia and titanium one-piece implants with and without microthreads in the neck: experimental and finite element analysis10.11607/jomi.7419 ↗
8. Biomechanical behavior of endodontically treated premolars restored with different endocrown designs: finite element study10.1016/j.jmbbm.2022.105309 ↗
9. Polyetherketoneketone (PEKK): an emerging biomaterial for oral implants and dental prostheses10.1016/j.jare.2020.09.004 ↗
10. Stress distribution of single-implant–retained overdenture reinforced with a framework: a finite element analysis study10.1016/j.prosdent.2017.07.016 ↗
11. Short dental implants: a systematic review10.1177/0022034511425675 ↗
12. In vitro performance of full-contour zirconia single crowns10.1016/j.dental.2011.11.024 ↗
13. The effect of eliminating implant/abutment rotational misfit on screw joint stability
14. Complication and failure rates of fixed dental prostheses in patients treated for periodontal disease10.1111/j.1600-0501.2010.02095.x ↗
15. Mechanical and surface properties of monolithic zirconia10.2341/17-019-L ↗
16. Mechanical evaluation of a patient-specific additively manufactured subperiosteal jaw implant (AMSJI) using finite-element analysis10.1016/j.ijom.2021.05.011 ↗
17. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla10.1080/10255842.2017.1287905 ↗
18. Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study since loading is increasingly believed to be a determining factor in the10.1034/j.1600-0501.2000.011005465.x ↗
19. Computer-aided finite element model for biomechanical analysis of orthodontic aligners10.1007/s00784-022-04692-7 ↗
20. Finite element analysis of different framework materials on maxillary palateless implant-supported overdenture prosthesis10.1007/s40846-023-00786-z ↗
21. Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers10.1111/j.1600-0501.2008.01556.x ↗
22. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study10.1016/j.prosdent.2017.03.008 ↗
23. The impact of cantilevers on biological and technical success outcomes of implant-supported fixed partial dentures. A retrospective cohort study10.1111/clr.12102 ↗
24. An in vivo study on load distribution in different implant configurations for supporting fixed partial dentures10.11607/jomi.4554 ↗
25. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years10.1111/j.1600-0501.2007.01414.x ↗
26. Comparative evaluation of a four-implant–supported Polyetherketoneketone framework prosthesis: a three-dimensional finite element analysis based on cone beam computed tomography and computer-aided design10.11607/ijp.5369 ↗
27. A longitudinal study of the survival of All-on-4 implants in the mandible with up to 10 years of follow-up10.14219/jada.archive.2011.0170 ↗
28. Immediate loading short implants inserted on low bone quantity for the rehabilitation of the edentulous maxilla using an All-on-4 design10.1111/joor.12291 ↗
29. A comparative analysis on two types of oral implants, bone-level and tissue-level, with different cantilever lengths of fixed prosthesis10.1111/jopr.12388 ↗
30. Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: a 3D FEA study10.1016/j.jobcr.2021.03.005 ↗
31. A prospective clinical trial of single Astra Tech 4.0 or 5.0 diameter implants used to support two-unit cantilever bridges: results after 3 years10.1111/j.1600-0501.2011.02160.x ↗
32. Metal free, full arch, fixed prosthesis for edentulous mandible rehabilitation on four implants10.1016/j.jpor.2017.10.002 ↗
33. Global oral health of older people-Call for public health action
34. Load factor control for implants in the posterior partially edentulous segment
35. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study
36. Verification of the influence of the arrangement of implants on the load distribution (a well-known figure by Rangert)10.1111/j.1365-2842.2011.02270.x ↗
37. The influence of various occlusal materials on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite-element study10.1002/jbm.b.30191 ↗
38. Evaluation of stresses on mandible bone and prosthetic parts in fixed prosthesis by utilizing CFR-PEEK, PEKK and PEEK frameworks10.1038/s41598-023-38288-2 ↗
39. Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture10.1016/j.compbiomed.2014.08.018 ↗
40. Stellingsma · 2004
41. Stress evaluation of implant-abutment connections under different loading conditions: a 3D finite element study10.1563/AAID-JOI-D-11-00205 ↗
42. Influence of different restoring materials on stress distribution in prosthesis on implants: a review of finite element studies
43. Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis
44. In vivo load measurement for evaluating the splinting effects of implant-supported superstructures: a pilot study10.11607/ijp.3223 ↗
45. Biomechanical analysis of inclined and cantilever design with different implant framework materials in mandibular complete-arch implant restorations10.1016/j.prosdent.2022.02.018 ↗
46. Effect of different implant configurations on biomechanical behavior of full-arch implant-supported mandibular monolithic zirconia fixed prostheses10.1016/j.jmbbm.2019.103490 ↗
47. Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic review10.1111/j.1600-0501.2009.01773.x ↗