journal article·2022-02Open access

An study on the influence of collagen fiber directions in TAVs performance using FEM

S. Suárez, J.A. López-Campos, A. Segade, C.G. Veiga, V.A. Jiménez

Abstract

Transcatheter Aortic Valve Implantation (TAVI) or Replacement (TAVR) is a promising treatment for aortic valve stenosis, consisting of a procedure to replace a damaged native aortic valve by a bioprosthetic one. This replacement valve control the flow of blood using leaflets that are similar to the ones of a native aortic valve. Commonly manufactured using bovine or porcine pericardium, it is a tissue histologically composed of collagen fibers embedded into a nearly-isotropic matrix, where their distribution makes the pericardium behave as an anisotropic hyperelastic material. Because of such complicated behavior, bioprosthetic pericardium valves are, as expected, sensitive to the distribution and orientation of these fibers in such device. Therefore, the objective of this work is a thorough systematic study on the influence of these fibers' distribution. First, a Finite Element model of a bioprosthetic valve is generated; then, a material routine to accurately describe the behavior of pericardium is implemented in a commercial software package; in addition, a dedicated algorithm to specify the direction of fibers is developed. Finally, a systematic study on the influence that fiber orientations have on the overall behavior of the TAV is performed. As a result of this study, two extreme behaviors are highlighted depending on the preferential orientation of collagen fibers; namely, one with fibers in circumferential direction and the opposite with fibers in an axial orientation. Then, it is concluded that the behavior of fibers in circumferential direction is very sensitive to small variations of the orientation angle, whereas such orientation is not as determining when the aim is to achieve a behavior near to the one corresponding with axial orientation.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Elasticity and Material Modeling · Tribology and Lubrication Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Boron · 2009
2. An in vivo study of the dimensional changes of the aortic valve leaflets during the cardiac cycle10.1016/S0022-5223(19)40896-9 ↗
3. Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium10.1016/j.jmbbm.2017.08.013 ↗
4. A new hyperelastic model for anisotropic hyperelastic materials with one fiber family10.1016/j.ijsolstr.2015.11.008 ↗
5. Overcoming volumetric locking in material point methods10.1016/j.cma.2018.01.010 ↗
6. Histological examination of explanted tissue-engineered bovine pericardium following heart valve repair10.1093/icvts/ivz234 ↗
7. Pseudoelasticity of arteries and the choice of its mathematical expression
8. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
9. Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole10.1016/S0021-9290(03)00293-8 ↗
10. Structure and anatomy of the aortic root10.1093/ejechocard/jen243 ↗
11. Holzapfel · 2000
12. A new constitutive framework for arterial wall mechanics and a comparative study of material models
13. Multiphysics simulation of the effect of leaflet thickness inhomogeneity and material anisotropy on the stress–strain distribution on the aortic valve10.1016/j.jbiomech.2016.02.041 ↗
14. Dynamic simulation of bioprosthetic heart valves using a stress resultant shell model10.1007/s10439-007-9409-4 ↗
15. Characterization of hyperelastic and damage behavior of tendons10.1080/10255842.2019.1710742 ↗
16. Characterization of mechanical properties of pericardium tissue using planar biaxial tension and flexural deformation10.1016/j.jmbbm.2017.08.039 ↗
17. Des lois géométriques qui régissent les déplacements d’un système solide dans l’espace, et de la variation des coordonnées provenant de ces déplacements considérés indépendamment des causes qui peuvent les produire
18. Orthotropic mechanical properties of chemically treated bovine pericardium10.1114/1.135 ↗
19. Age-related changes in aortic and mitral valve thickness: implications for two-dimensional echocardiography based on an autopsy study of 200 normal human hearts10.1016/0002-9149(88)90971-X ↗
20. A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment10.1186/s40759-014-0002-x ↗
21. Volume measurement algorithm for food product with irregular shape using computer vision based on Monte Carlo method10.5614/itbj.ict.res.appl.2014.8.1.1 ↗
22. Spencer · 1971
23. Simulated bioprosthetic heart valve deformation under quasi-static loading10.1115/1.2049337 ↗
24. Simulated elliptical bioprosthetic valve deformation: Implications for asymmetric transcatheter valve deployment10.1016/j.jbiomech.2010.08.010 ↗
25. Computational optimization study of transcatheter aortic valve leaflet design using porcine and bovine leaflets10.1115/1.4044244 ↗