Computational modeling of braided venous stents — Effect of design features and device-tissue interaction on stent performance
Source abstract
Abstract
Designing venous stents with desired properties is challenging due to the partly conflicting performance criteria, e.g., enhancing flexibility may be at odds with increasing patency. To evaluate the effect of design parameters on the mechanical performance of braided stents, computational simulations are performed using finite element analysis. Model validation is performed through comparison with measurements. Considered design features are stent length, wire diameter, pick rate, number of wires, and stent end-type, being either open-ended or closed looped. Based on the requirements of venous stents, tests are defined to study the effect of design variations with respect to the following key performance criteria: chronic outward force, crush resistance, conformability, and foreshortening. Computational modeling is demonstrated to be a valuable tool in the design process through its ability of assessing sensitivities of various performance metrics to the design parameters. Additionally, it is shown, using computational modeling, that the interaction between a braided stent and its surrounding anatomy has a significant impact on its performance. Therefore, taking into account device-tissue interaction is crucial for the proper assessment of stent performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Vascular Procedures and Complications · Vascular Malformations Diagnosis and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Carotid artery stenting simulation: From patient-specific images to finite element analysis10.1016/j.medengphy.2010.10.011 ↗
2. Iliac veins are more compressible than iliac arteries: A new method of testing10.1115/1.4044227 ↗
3. Clauwaert · 2012
4. Conti · 2007
5. Physical properties of venous stents: An experimental comparison10.1007/s00270-018-1916-1 ↗
6. Expert recommendations on the assessment of wall shear stress in human coronary arteries: existing methodologies, technical considerations, and clinical applications10.1093/eurheartj/ehz551 ↗
7. Numerical modeling of bare and polymer-covered braided stents using torsional and tensile springs connectors10.1016/j.jbiomech.2021.110459 ↗
8. A study of the geometrical and mechanical properties of a self-expanding metallic stent—theory and experiment10.1002/jab.770040111 ↗
9. Wall shear stress in the development of in-stent restenosis revisited. A critical review of clinical data on shear stress after intracoronary stent implantation10.5603/CJ.a2016.0047 ↗
10. Mechanical modeling of self-expandable stent fabricated using braiding technology10.1016/j.jbiomech.2008.08.005 ↗
11. Cardiovascular stent design and vessel stresses: a finite element analysis10.1016/j.jbiomech.2004.07.022 ↗
12. Loo · 2006
13. Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms10.1016/j.jbiomech.2012.06.013 ↗
14. The cause of the predominantly sinistral occurrence of thrombosis of the pelvic veins10.1177/000331975700800505 ↗
15. Surveying the 2019 venous stent landscape
16. Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods10.1016/j.jmbbm.2017.08.025 ↗
17. Viscoelastic braided stent: Finite element modelling and validation of crimping behaviour10.1016/j.matdes.2017.02.044 ↗
18. Mechanical response of a metallic aortic stent—Part I: Pressure-diameter relationship10.1115/1.1782650 ↗
19. Mechanical response of a metallic aortic stent—Part II: A beam-on-elastic foundation model10.1115/1.1782912 ↗
20. Long-term outcomes of stent placement for symptomatic nonthrombotic iliac vein compression lesions in chronic venous disease10.1016/j.jvir.2011.12.021 ↗
21. Modeling of braided stents: Comparison of geometry reconstruction and contact strategies10.1016/j.jbiomech.2020.109841 ↗
22. Analytical methods for braided stents design and comparison with FEA10.1016/j.jmbbm.2021.104560 ↗
23. Models of stents – Comparison and applications