Comparison of stress distribution in fully porous and dense-core porous scaffolds in dental implantation
Source abstract
Abstract
The aim of this study is to compare the stress distribution in porous scaffolds with different structures with similar geometric parameters to study a new approach in dental implantation. Three-dimensional finite element models of the fully porous and dense-core porous scaffolds with defined porosity parameters including space diameter and thickness with two porosity patterns were embedded in the jaw bone model with cortical and cancellous bone. The cylindrical shape was considered as the main shape of the scaffolds. To evaluate the mechanical performance, the Von Mises stress was compared in the models under static and dynamic masticatory loading. Incidentally, to validate the modeling results, experimental strain gauge tests were performed on four specimens fabricated from Ti6Al4V. Finally, the stress distribution in the models was compared with the results of previous studies on commercial implants. The results of the finite element analysis show that there are considerable differences in the magnitude of the equivalent stress in the models in static and dynamic phases. Also, changes in the defined geometric parameters have significant effects on the stress distribution in terms of Von Mises stress in the overall models. The experimental results indicated good agreement with those of the modeling. It can be concluded that some porous structures with optimal geometries can be proposed as a new structure for dental implants. However, considering the physiology of bone when confronted with porous structures, further studies such as in vivo experiments are needed in this field.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. Porous scaffolds for bone regeneration
2. Peri-implant bone response around porous-surface dental implants: a preclinical meta-analysis. Saudi
3. Relationship between implant length and implant stability of single-implant restorations: a 12-month follow-up clinical study10.3390/medicina56060263 ↗
4. Porous metal implants: processing, properties, and challenges10.1088/2631-7990/acdd35 ↗
5. Composition and modifications of dental implant surfaces10.1155/2015/527426 ↗
6. Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial10.1186/s12903-020-01283-4 ↗
7. Stress distribution of two commercial dental implant systems: a three-dimensional finite element analysis10.1016/j.jds.2012.04.006 ↗
8. Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process10.1186/s40729-018-0119-5 ↗
9. Porous scaffold design for additive manufacturing in orthopedics: a review10.3389/fbioe.2020.00609 ↗
10. Risk factors related to late failure of dental implant-A systematic review of recent studies10.3390/ijerph17113931 ↗
11. Optimum location of a three strain gauge rosette for measuring mixed mode stress intensity factors10.1016/j.engfracmech.2008.03.014 ↗
12. Agglomeration effect on biomechanical performance of CNT-reinforced dental implant using micromechanics-based approach10.1016/j.jmbbm.2023.106023 ↗
13. Mandibular bone remodeling around osseointegrated functionally graded biomaterial implant using three dimensional finite element model
14. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis. Head. Face
15. Biomechanical behaviour of bone-implant interface: a review10.1098/rsif.2019.0259 ↗
16. Finite element analysis of dental implants with and without microthreads under static and dynamic loading10.1615/JLongTermEffMedImplants.2017020007 ↗
17. Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis10.5125/jkaoms.2018.44.2.59 ↗
18. Biomaterials for bone regeneration: an orthopedic and dentistry overview10.1590/1414-431x2021e11055 ↗
19. Mechanical basis of bone strength: influence of bone material, bone structure and muscle action. J. Musculoskelet. Neuronal
20. Stress constrained topology optimization10.1007/s00158-012-0880-7 ↗
21. Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method; A systematic review10.4047/jap.2022.14.3.182 ↗
22. 2007
23. Design of experiments (DoE) based optimization of dental implants: a review10.1063/5.0057944 ↗
24. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation
25. Structure optimization of porous dental implant based on 3D printing10.1088/1757-899X/324/1/012060 ↗
26. Comparison of trabecular bone mineral density measurement using hounsfield unit and trabecular microstructure in orthodontic patients using cone beam computed tomography10.3390/app11031028 ↗
27. Additively manufactured porous Ti6Al4V for bone implants: a review10.3390/met12040687 ↗
28. Evaluation of biological properties of electron beam melted Ti6Al4V implant with biomimetic coating in vitro and in vivo10.1371/journal.pone.0052049 ↗
29. The optimization of Ti gradient porous structure involves the finite element simulation analysis
30. Higher-order finite elements for embedded simulation10.1145/3414685.3417853 ↗
31. The contribution of experimental in vivo models to understanding the mechanisms of adaptation to mechanical loading in bone10.3389/fendo.2014.00154 ↗
32. 3D printed bone models in oral and cranio-maxillofacial surgery: a systematic review10.1186/s41205-020-00088-z ↗
33. Bioinspired porous dental implants using the concept of 3D printing to investigate the effect of implant type and porosity on patient's bone condition
34. Advances in porous biomaterials for dental and orthopaedic applications10.3390/ma3052947 ↗
35. Diagnostic imaging for dental implant therapy10.4103/2156-7514.143440 ↗
36. A critical review of dental implant materials with an emphasis on titanium versus zirconia10.3390/ma8030932 ↗
37. Scaffold design for bone regeneration10.1166/jnn.2014.9127 ↗
38. Application of finite element model in implant dentistry: a systematic review10.4103/JPBS.JPBS_296_18 ↗
39. Optimal selection of dental implant for different bone conditions based on the mechanical response
40. To reduce the maximum stress and the stress shielding effect around a dental implant–bone interface using radial functionally graded biomaterials10.1080/10255842.2017.1299142 ↗
41. Stability of dental implants and thickness of cortical bone: clinical research and future perspectives: a systematic review10.3390/ma14237183 ↗
42. Approach to the fatigue and cellular behavior of superficially modified porous titanium dental implants10.3390/ma15113903 ↗
43. Application of the finite element method in dental implant research10.1080/10255840600837074 ↗
44. Micro-Strain around dental implant supporting fixed partial Prostheses under axial and Non-Axial Loading conditions, In-Vitro Strain Gauge Analysis10.1097/SCS.0b013e31829ac83d ↗
45. Bone quality assessment of dental implant recipient sites
46. Porous titanium for dental implant applications10.3390/met5041902 ↗
47. Fatigue behavior and osseointegration of porous Ti-6Al-4V scaffolds with dense core for dental application
48. Implant design and stress distribution10.5005/jp-journals-10012-1151 ↗
49. Buckling responses of porous structural components with gradient power-based and sigmoid material variations under different types of compression loads
50. Optimization of stress distribution of bone-implant interface (BII)10.1016/j.bioadv.2023.213342 ↗
51. Mechanical strength of dental implants