A Bayesian method with nonlinear noise model to calibrate constitutive parameters of soft tissue
Source abstract
Abstract
The measured mechanical responses of soft tissue exhibit large variability and errors, especially for the softest brain tissue, while calibrating its constitutive parameters in a deterministic way remains a common practice. Here we implement a Bayesian method considering the nonlinear noise model to calibrate constitutive parameters of brain tissue. A probability model is first developed based on the measured experimental data, likelihood function, and prior function, from which the posterior distributions of model parameters are formulated. The likelihood function considers the nonlinear behaviors of the constitutive response and noise distribution of the experimentally measured data. Meanwhile, the prior predictive distribution is computed to check the probability model preliminarily. Secondly, the Markov Chain Monte Carlo (MCMC) method is used to compute the posterior distributions of model parameters, enabling assessment of parameter uncertainty, correlation, and model calibration error. Finally, the posterior predictive distributions of the overall response, constitutive response, and noise response are computed to validate the probabilistic model, all of which are consistent with the corresponding data. Furthermore, the effect of the prior distribution, experimental data, and noise model on posterior distribution is studied. Our study provides a general approach to calibrating constitutive parameters of soft tissue despite errors and large variability in experimental data.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Automotive and Human Injury Biomechanics · Elasticity and Material Modeling · Effects of Vibration on Health
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Modelling brain tissue elasticity with the Ogden model and an alternative family of constitutive models
2. Regional variations in stiffness in live mouse brain tissue determined by depth-controlled indentation mapping10.1038/s41598-018-31035-y ↗
3. Towards brain-tissue-like biomaterials10.1038/s41467-020-17245-x ↗
4. 5 - elasticity/hyperelasticity
5. Uncertainty quantification for constitutive model calibration of brain tissue10.1016/j.jmbbm.2018.05.037 ↗
6. Fifty shades of brain: a review on the mechanical testing and modeling of brain tissue10.1007/s11831-019-09352-w ↗
7. Towards microstructure-informed material models for human brain tissue10.1016/j.actbio.2019.12.030 ↗
8. Mechanical characterization of human brain tissue10.1016/j.actbio.2016.10.036 ↗
9. Rheological characterization of human brain tissue10.1016/j.actbio.2017.06.024 ↗
10. The role of mechanics during brain development10.1016/j.jmps.2014.07.010 ↗
11. Fifty years of brain tissue mechanical testing: from in vitro to in vivo investigations
12. Measurement of viscoelastic properties of injured mouse brain after controlled cortical impact10.1007/s41048-020-00110-1 ↗
13. Revealing the effect of skull deformation on intracranial pressure variation during the direct interaction between blast wave and surrogate head10.1007/s10439-022-02982-5 ↗
14. Revealing the nonlinear mechanical behavior of white matter brain tissue by analyzing the asynchronous deformation and damage of matrix and axonal fibers10.1016/j.ijsolstr.2022.111554 ↗
15. Regional mechanical properties of human brain tissue for computational models of traumatic brain injury10.1016/j.actbio.2017.03.037 ↗
16. Mechanics of the brain: perspectives, challenges, and opportunities10.1007/s10237-015-0662-4 ↗
17. Simulated brain tumor growth dynamics using a three-dimensional cellular automaton10.1006/jtbi.2000.2000 ↗
18. Hierarchical multiscale quantification of material uncertainty10.1016/j.jmps.2021.104492 ↗
19. A viscoelastic analysis of the P56 mouse brain under large-deformation dynamic indentation10.1016/j.actbio.2016.10.029 ↗
20. A Bayesian approach to selecting hyperelastic constitutive models of soft tissue10.1016/j.cma.2015.03.012 ↗
21. Bayesian calibration of hyperelastic constitutive models of soft tissue10.1016/j.jmbbm.2015.10.025 ↗
22. Skull flexure from blast waves: a mechanism for brain injury with implications for helmet design10.1103/PhysRevLett.103.108702 ↗
23. Bayesian calibration of a physics-based crystal plasticity and damage model10.1016/j.jmps.2020.104284 ↗
24. Biomechanics of brain tissue10.1016/j.actbio.2010.06.035 ↗
25. Dynamic mechanical response of brain tissue in indentation in vivo, in situ and in vitro10.1016/j.actbio.2011.06.032 ↗
26. Viscoelastic characterization of injured brain tissue after controlled cortical impact (CCI) using a mouse model10.1016/j.jneumeth.2019.108463 ↗
27. A tutorial on bayesian inference to identify material parameters in solid mechanics10.1007/s11831-018-09311-x ↗
28. Network dysfunction after traumatic brain injury10.1038/nrneurol.2014.15 ↗
29. Anisotropic mechanical properties in the healthy human brain estimated with multi-excitation transversely isotropic MR elastography10.1016/j.brain.2022.100051 ↗
30. On the growth and form of cortical convolutions10.1038/nphys3632 ↗
31. Medical robotics and computer-integrated surgery10.1007/978-3-319-32552-1_63 ↗
32. A Bayesian model calibration framework to evaluate brain tissue characterization experiments10.1016/j.cma.2019.112604 ↗
33. Anisotropic constitutive equations and experimental tensile behavior of brain tissue10.1007/s10237-005-0007-9 ↗
34. Bayesian inference of the spatial distributions of material properties10.1016/j.jmps.2018.05.007 ↗
35. Origins of brain tissue elasticity under multiple loading modes by analyzing the microstructure-based models
36. Mechanical stiffness and anisotropy measured by MRE during brain development in the minipig10.1016/j.neuroimage.2023.120234 ↗
37. Brain stiffness increases with myelin content10.1016/j.actbio.2016.07.040 ↗