The impact of femoral head size on the wear evolution at contacting surfaces of total hip prostheses: A finite element analysis
Source abstract
Abstract
Total Hip Arthroplasty has been a revolutionary technique in restoring mobility to patients with damaged hip joints. The introduction of modular components of the hip prosthesis allowed for bespoke solutions based on the requirements of the patient. The femoral stem is designed with a conical trunnion to allow for assembly of different femoral head sizes based on surgical requirements. The femoral head diameters for a metal-on-polyethylene hip prosthesis have typically ranged between 22 mm and 36 mm and are typically manufactured using Cobalt–Chromium alloy. A smaller femoral head diameter is associated with lower wear of the polyethylene, however, there is a higher risk of dislocation. In this study, a finite element model of a standard commercial hip arthroplasty prosthesis was modelled with femoral head diameters ranging from 22 mm to 36 mm to investigate the wear evolution and material loss at both contacting surfaces (acetabular cup and femoral stem trunnion). The finite element model, coupled with a validated in-house wear algorithm modelled a human walking for 10 million steps. The results have shown that as the femoral head size increased, the amount of wear on all contacting surfaces increased. As the femoral head diameter increased from 22 mm to 36 mm, the highly cross-linked polyethylene (XLPE) volumetric wear increased by 61% from 98.6 mm3 to 159.5 mm3 while the femoral head taper surface volumetric wear increased by 21% from 4.18 mm3 to 4.95 mm3. This study has provided an insight into the amount of increased wear as the femoral head size increased which can highlight the life span of these prostheses in the human body.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene10.3109/17453679908997845 ↗
2. HIP-SIMULATOR wear comparisons of cocr/cocr versus cocr/pe THR at 10 million cycles
3. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
4. Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation10.1016/j.jbiomech.2017.07.027 ↗
5. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients10.1302/0301-620X.99B12.BJJ-2017-0353.R1 ↗
6. Hip simulator testing of the taper-trunnion junction and bearing surfaces of contemporary metal-on-cross-linked-polyethylene hip prostheses10.1002/jbm.b.34374 ↗
7. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes: an in vitro study10.1016/j.arth.2004.07.008 ↗
8. Revision total hip arthroplasty in hip joints with metallosis: a single-center experience with 31 cases10.1016/j.arth.2005.04.001 ↗
9. Metallosis after metal-on-polyethylene total hip arthroplasty
10. Total Hip Arthroplasty, state of the art for the 21st century10.1007/s00264-011-1207-9 ↗
11. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear10.1007/s11420-012-9287-7 ↗
12. de Steiger · 2017
13. Highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty: a 10-year double-blinded randomized controlled trial10.2106/JBJS.16.00878 ↗
14. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
15. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
16. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
17. Friction in femoral prosthesis and photoelastic model cone taper joints10.1243/PIME_PROC_1989_203_003_01 ↗
18. Retrieval analysis of large-head modular metal-on-metal hip replacements of a single design10.1016/j.arth.2017.12.044 ↗
19. The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis: an analysis of 78,098 operations in the Swedish Hip Arthroplasty Register10.3109/17453674.2012.733919 ↗
20. Wear in retrieved charnley acetabular sockets10.1243/PIME_PROC_1996_210_413_02 ↗
21. Wear and range of motion of different femoral head sizes10.1016/j.arth.2009.07.007 ↗
22. Wear rates of larger-diameter cross-linked polyethylene at 5 to 13 Years: does liner thickness or component position matter?10.1016/j.arth.2016.11.022 ↗
23. “True” cumulative Incidence of and risk Factors for hip Dislocation within 2 Years after primary total hip arthroplasty Due to osteoarthritis: a nationwide population-based Study from the Danish hip arthroplasty register10.2106/JBJS.19.01352 ↗
24. A comparison of revision rates and dislocation after primary total hip arthroplasty with 28, 32, and 36-mm femoral heads and different cup sizes: an analysis of 188,591 primary total hip arthroplasties10.2106/JBJS.21.01101 ↗
25. A case example and literature review of catastrophic wear before catastrophic failure: identification of trunnionosis and metallosis in metal-on-polyethylene hip arthroplasty prior to frank failure or fracture10.1007/s00590-018-2333-5 ↗
26. Large diameter femoral heads
27. A review of UHMWPE wear-induced osteolysis: the role for early detection of the immune response10.1038/boneres.2016.14 ↗
28. Wear rates of XLPE nearly 50% lower than previously thought after adjusting for initial creep: an RCT comparing 4 bearing combinations10.2106/JBJS.OA.19.00066 ↗
29. Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty: a population-based analysis of 42,379 primary procedures from the Finnish Arthroplasty Register10.3109/17453674.2013.810518 ↗
30. Effect of femoral head size and abductors on dislocation after revision THA10.1097/BLO.0b013e318159a983 ↗
31. Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 Years: the effect of femoral head size10.1007/s11999-015-4319-5 ↗
32. Taper junction failure in large-diameter metal-on-metal bearings10.1302/2046-3758.14.2000047 ↗
33. A comparison study of stem taper material loss at similar and mixed metal head-neck taper junctions10.1302/0301-620X.99B10.BJJ-2016-1005.R1 ↗
34. Material loss at the femoral head taper10.1302/0301-620X.100B10.BJJ-2017-0406.R3 ↗
35. Total hip wear assessment: a comparison between computational and in vitro wear assessment techniques using ISO 14242 loading and kinematics10.1115/1.3049477 ↗
36. Effects of the femoral offset and the head size on the safe range of motion in total hip arthroplasty10.1016/j.arth.2008.02.008 ↗
37. Humeral and femoral head diameters in recent white American skeletons10.1111/j.1556-4029.2011.01953.x ↗
38. 2021 · 2021
39. 2022 · 2022
40. Taper-trunnion interface stress varies significantly with head size and activity10.1016/j.arth.2018.09.004 ↗
41. Quantitative assessment of walking activity after total hip or knee replacement
42. Computational method for bearing surface wear prediction in total hip replacements
43. Computational method for bearing surface wear prediction in total hip replacements10.1016/j.jmbbm.2021.104507 ↗
44. The relation between body weight and wear in Total Hip Prosthesis: a finite element study10.1016/j.cmpbup.2022.100060 ↗
45. Toh · 2022
46. Head size in primary total hip arthroplasty10.1302/2058-5241.3.170061 ↗
47. No increase in survival for 36-mm versus 32-mm femoral heads in metal-on-polyethylene THA: a Registry study10.1097/CORR.0000000000000508 ↗
48. Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset10.1177/1120700018814473 ↗
49. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome
50. Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator
51. A finite element methodology for wear–fatigue analysis for modular hip implants10.1016/j.triboint.2013.02.016 ↗