A mechano-regulation model to design and optimize the surface microgeometry of titanium textured devices for biomedical applications
Source abstract
Abstract
In a technological context where, thanks to the additive manufacturing techniques, even sophisticated geometries as well as surfaces with specific micrometric features can be realized, we propose a mechano-regulation algorithm to determine the optimal microgeometric parameters of the surface of textured titanium devices for biomedical applications. A poroelastic finite element model was developed including a portion of bone, a portion of a textured titanium device and a layer of granulation tissue separating the bone from the device and occupying the space between them. The algorithm, implemented in the Matlab environment, determines the optimal values of the root mean square and the correlation length that the device surface must possess to maximize bone formation in the gap between the bone and the device. For low levels of compression load acting on the bone, the algorithm predicts low values of root mean square and high values of correlation length. Conversely, high levels of load require high values of root mean square and low values of correlation length. The optimal microgeometrical parameters were determined for various thickness values of the granulation tissue layer. Interestingly, the predictions of the proposed computational model are consistent with the experimental results reported in the literature. The proposed algorithm shows promise as a valuable tool for addressing the demands of precision medicine. In this approach, the device or prosthesis is no longer designed solely based on statistical averages but is tailored to each patient's unique anthropometric characteristics, as well as considerations related to their metabolism, sex, age, and more.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Dental materials and restorations · Advanced machining processes and optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. As-built EBM and DMLS Ti-6Al-4V parts: Topography–corrosion resistance relationship in a simulated body fluid10.3390/met10081015 ↗
2. Bone ingrowth simulation for a concept glenoid component design10.1016/j.jbiomech.2004.05.044 ↗
3. Computational mechanobiology to study the effect of surface geometry on peri-implant tissue differentiation10.1115/1.2970057 ↗
4. In silico assessment of the bone regeneration potential of complex porous scaffolds10.1016/j.compbiomed.2023.107381 ↗
5. Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating10.1007/s10856-012-4836-7 ↗
6. Rhombicuboctahedron unit cell based scaffolds for bone regeneration: geometry optimization with a mechanobiology – driven algorithm10.1016/j.msec.2017.09.004 ↗
7. A model of tissue differentiation and bone remodelling in fractured vertebrae treated with minimally invasive percutaneous fixation10.1007/s11517-012-0937-1 ↗
8. A mechano-regulation model of fracture repair in vertebral bodies10.1002/jor.21231 ↗
9. The influence of expansion rates on mandibular distraction osteogenesis: a computational analysis10.1007/s10439-007-9367-x ↗
10. Tissue differentiation and bone regeneration in an osteotomized mandible: a computational analysis of the latency period10.1007/s11517-007-0247-1 ↗
11. Optimal load for bone tissue scaffolds with an assigned geometry10.7150/ijms.20522 ↗
12. Simulation of tissue differentiation in a scaffold as a function of porosity, Young's modulus and dissolution rate: application of mechanobiological models in tissue engineering10.1016/j.biomaterials.2007.09.003 ↗
13. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants10.1016/j.jmbbm.2018.07.019 ↗
14. Characteristics and efficacy of a new 3-dimensional printed mesh structure titanium alloy spacer for posterior lumbar interbody fusion10.3928/01477447-20170810-04 ↗
15. 3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth10.1186/s13036-021-00255-8 ↗
16. Electron beam additive manufacturing of titanium components: properties and performance10.1115/1.4025773 ↗
17. The effect of EBM process parameters upon surface roughness10.1108/RPJ-10-2013-0102 ↗
18. An electron beam melting system for in-situ synchrotron X-ray monitoring10.1016/j.addlet.2022.100094 ↗
19. Actual state-of-the-art of electron beam powder bed fusion10.1080/26889277.2022.2040342 ↗
20. Modelling the role of surface stress on the kinetics of tissue growth in confined geometries10.1016/j.actbio.2012.10.020 ↗
21. Biomechanical behaviours of the bone-implant interface: a review10.1098/rsif.2019.0259 ↗
22. Monte Carlo calculation for electromagnetic-wave scattering from random rough surfaces10.1103/PhysRevLett.52.1798 ↗
23. The influence of macro-textural designs over implant surface on bone on-growth: a computational mechanobiology based study10.1016/j.compbiomed.2020.103937 ↗
24. Porous tantalum and titanium in orthopedics: a review10.1021/acsbiomaterials.9b00493 ↗
25. Impact of bone-implant gap size on the interfacial osseointegration: an in vivo study
26. A biomechanical regulatory model for periprosthetic fibrous-tissue differentiation10.1023/A:1018520914512 ↗
27. Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction10.1007/s10237-022-01637-7 ↗
28. Mechano-regulation of stem cell differentiation and tissue regeneration in osteochondral defects10.1016/j.jbiomech.2004.06.026 ↗
29. Is a titanium implant for total knee arthroplasty better? A randomized controlled study10.1016/j.arth.2020.11.010 ↗
30. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading10.1016/S0021-9290(02)00086-6 ↗
31. Biomechanical model to simulate tissue differentiation and bone regeneration: application to fracture healing10.1007/BF02347690 ↗
32. Bone remodeling and mechanobiology around implants: insights from small animal imaging10.1002/jor.23758 ↗
33. Direct metal laser sintering titanium dental implants: a review of the current literature10.1155/2014/461534 ↗
34. Histological evidence of the osseointegration of fractured direct metal laser sintering implants retrieved after 5 Years of function10.1155/2017/9732136 ↗
35. Clinical and radiographic outcomes of hybrid glenoid fixation with a central porous titanium post: analysis of 713 consecutive shoulders10.1016/j.jse.2021.12.033 ↗
36. Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model10.1016/j.spinee.2018.02.018 ↗
37. Towards multi-dynamic mechano-biological optimization of 3D-printed scaffolds to foster bone regeneration10.1016/j.actbio.2019.10.029 ↗
38. Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm10.1007/s10237-015-0696-7 ↗
39. Excellent results of primary THA using a highly porous titanium cup10.3928/01477447-20130327-10 ↗
40. Surgical tip: titanium foam blocks can simplify fusion of failed total ankle replacements10.1016/j.foot.2014.06.002 ↗
41. Mechanobiological approach to design and optimize bone tissue scaffolds 3D printed with fused deposition modeling: a feasibility study10.3390/ma13030648 ↗
42. Initial mechanical conditions within an optimized bone scaffold do not ensure bone regeneration – an in silico analysis10.1007/s10237-021-01472-2 ↗
43. Biomimetics for the induction of bone formation10.1586/erd.10.17 ↗
44. Osteoinductive hydroxyapatite-coated titanium implants10.1016/j.biomaterials.2012.01.050 ↗
45. Irregular load adapted scaffold optimization: a computational framework based on mechanobiological criteria10.1021/acsbiomaterials.9b01023 ↗
46. Comparison of the mechanobiological performance of bone tissue scaffolds based on different unit cell geometries10.1016/j.jmbbm.2018.04.008 ↗
47. Osseointegration of coarse and fine textured implants manufactured by electron beam melting and direct metal laser sintering10.1089/3dp.2017.0008 ↗
48. Titanium alloys for hip joint replacements10.1016/0267-6605(87)90015-1 ↗
49. Biocompatibility of advanced manufactured titanium implants-A review10.3390/ma7128168 ↗
50. Titanium dental implants: an overview of applied nanobiotechnology to improve biocompatibility and prevent infections10.3390/ma15093150 ↗
51. Failure of acrylic bone cements under triaxial stresses10.1007/BF03372202 ↗
52. Comparison of residual stresses in inconel 718 simple parts made by electron beam melting and direct laser metal sintering10.1007/s11661-014-2722-2 ↗
53. Structural and topological design of conformal bilayered scaffolds for bone tissue engineering10.1016/j.tws.2023.111209 ↗
54. The effect of 3D-printed Ti6Al4V scaffolds with various macropore structures on osteointegration and osteogenesis: a biomechanical evaluation10.1016/j.jmbbm.2018.08.049 ↗
55. A comparison of biocompatibility of a titanium alloy fabricated by electron beam melting and selective laser melting
56. Effects of processing parameters on surface roughness of additive manufactured Ti-6Al-4V via electron beam melting
57. Performance of porous tantalum vs. Titanium cup in total hip arthroplasty: randomized trial with minimum 10-year follow-up10.1016/j.arth.2015.01.013 ↗
58. Biomechanical and histological evaluation of roughened surface titanium screws fabricated by electron beam melting
59. Chapter 11. Anisotropic surfaces