journal article·2014-05

Clinical versus pre-clinical FE models for vertebral body strength predictions

Dieter H. Pahr, Jakob Schwiedrzik, Enrico Dall'Ara, Philippe K. Zysset

Publisher page

Abstract

The finite element analysis is an accepted method to predict vertebral body compressive strength. This study compares measurements obtained from in vitro tests with the ones from two different simulation models: clinical quantitative computer tomography (QCT) based homogenized finite element (hFE) models and pre-clinical high-resolution peripheral QCT-based (HR-pQCT) hFE models. About 37 vertebral body sections were prepared by removing end-plates and posterior elements, scanned with QCT (390/450μm voxel size) as well as HR-pQCT (82μm voxel size), and tested in compression up to failure. Non-linear viscous damage hFE models were created from QCT/HT-pQCT images and compared to experimental results based on stiffness and ultimate load. As expected, the predictability of QCT/HR-pQCT-based hFE models for both apparent stiffness (r(2)=0.685/0.801) and strength (r(2)=0.774/0.924) increased if a better image resolution was used. An analysis of the damage distribution showed similar damage locations for all cases. In conclusion, HR-pQCT-based hFE models increased the predictability considerably and do not need any tuning of input parameters. In contrast, QCT-based hFE models usually need some tuning but are clinically the only possible choice at the moment.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Medical Imaging and Analysis · Elasticity and Material Modeling · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Adams, M.F., Bayraktar, H.H., Keaveny, T.M., Papadopoulos, P., 2004. Ultrascalable implicit finite element analyses in solid mechanics with over a half a billion degrees of freedom. In: Proceedings of the 2004 ACM/IEEE Conference on Supercomputing, IEEE Computer Society, p. 34.10.1109/SC.2004.62 ↗
2. A scalable multi-level preconditioner for matrix-free micro-finite element analysis of human bone structures10.1002/nme.2101 ↗
3. Comparison of quantitative computed tomography-based measures in predicting vertebral compressive strength10.1016/j.bone.2006.10.025 ↗
4. Cement distribution, volume, and compliance in vertebroplasty10.1097/BRS.0b013e31817c750b ↗
5. The role of cortical shell and trabecular fabric in finite element analysis of the human vertebral body10.1115/1.3212097 ↗
6. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
7. A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro10.1016/j.jbiomech.2010.04.023 ↗
8. A calibration methodology of qct bmd for human vertebral body with registered micro-ct images10.1118/1.3582946 ↗
9. A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro
10. Qct-based finite element models predict human vertebral strength in vitro significantly better than simulated dexa10.1007/s00198-011-1568-3 ↗
11. The micro-mechanics of cortical shell removal in the human vertebral body10.1016/j.cma.2006.06.017 ↗
12. Effect of bone distribution on vertebral strength10.1148/radiology.179.3.2027972 ↗
13. Role of trabecular microarchitecture in whole-vertebral body biomechanical behavior10.1359/jbmr.090317 ↗
14. Improvements in vertebral body strength under teriparatide treatment assessed in vivo by finite element analysis: results from the EUROFORS study10.1359/jbmr.090416 ↗
15. Osteoporosis changes the amount of vertebral trabecular bone at risk of fracture but not the vertebral load distribution10.1097/00007632-200107150-00010 ↗
16. The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent “error” loads10.1016/j.bone.2003.12.001 ↗
17. Nonlinear finite element model predicts vertebral bone strength and fracture site10.1097/01.brs.0000225993.57349.df ↗
18. Robust generation of high-quality unstructured meshes on realistic biomedical geometry10.1002/nme.1482 ↗
19. Assessment of factors influencing finite element vertebral model predictions10.1115/1.2800791 ↗
20. Finite element analysis of the spine10.1016/j.medengphy.2008.09.006 ↗
21. Lemaitre · 2005
22. Finite element modeling of the human thoracolumbar spine10.1097/01.BRS.0000049923.27694.47 ↗
23. Removal of the cortical endplates has little effect on ultimate load and damage distribution in QCT-based voxel models of human lumbar vertebrae under axial compression10.1016/j.jbiomech.2012.03.019 ↗
24. Noninvasive assessment of stiffness and failure load of human vertebrae from CT-data10.1515/bmte.1998.43.4.82 ↗
25. A comparison of enhanced continuum FE with micro FE models of human vertebral bodies10.1016/j.jbiomech.2008.11.028 ↗
26. From high-resolution CT data to finite element models10.1080/10255840802144105 ↗
27. Pahr, D.H., Dall'Ara, E., Varga, P., Zysset, P.K., 2011. HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models. Computer Methods in Biomechanics and Biomedical Engineering.10.1080/10255842.2011.556627 ↗
28. Perzyna · 1966
29. Multi-axial mechanical properties of human trabecular bone10.1007/s10237-008-0128-z ↗
30. The material mapping strategy influences the accuracy of CT-based finite element models of bones10.1016/j.medengphy.2006.10.014 ↗
31. Regularised marching tetrahedra10.1016/S0097-8493(99)00076-X ↗
32. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
33. A comparative study on different methods of automatic mesh generation of human femurs10.1016/S1350-4533(97)00049-0 ↗
34. Zysset, P.K., 1994. A constitutive law for trabecular bone. Ph.D. Thesis, Ecole Polytechnique Federale de Lausanne.
35. An alternative model for anisotropic elasticity based on fabric tensors10.1016/0167-6636(95)00018-6 ↗
36. An alternative fabric-based yield and failure criterion for trabecular bone