Life expectancy of modular Ti6Al4V hip implants: Influence of stress and environment
Source abstract
Abstract
Stress dependent electrochemical dissolution is identified as one of the key mechanisms governing surface degradation in fretting and crevice corrosion of biomedical implants. The present study focuses on delineating the roles of mechanical stress and chemical conditions on the life expectancy of modular hip implants. First, material removal on a stressed surface of Ti6Al4V subjected to single asperity contact is investigated experimentally to identify the influence of contact load, in-plane stress and chemical environment on mean wear rates. A range of known stress levels are applied to the specimen while its surface is mechanically stimulated in different non-reactive to oxidizing aqueous environments. Evolution of surface degradation is monitored, and its mechanism is elucidated. This phase allows estimation of Preston Constant which is later used in the analysis. Second phase of the work is semi-analytical and computational, where, based on the estimated Preston constant and other material and process parameters, the scratch propensity (consisting of magnitude of scratch depth and their frequency per unit area) due to micro-motion in modular hip implants is estimated. The third phase views these scratches as initial notches and utilizes a mixed-mode fatigue crack propagation model to estimate the critical crack length for onset of instability. The number of loading cycles needed to reach this critical crack length is then labeled as the expected life of the implant under given mechanical and chemical conditions. Implications of different material and process conditions to life expectancy of orthopedic implants are discussed. It is observed that transverse micro-motion, compared to longitudinal micro-motion, plays a far more critical role in determining the implant life. Patient body weight, as well as proximity of the joint fluid to its iso-electric point play key roles in determining wear rates and associated life expectancies of modular hip implants. Sustained aeration of joint fluid, as well as proper tolerancing of mating surfaces, along with a proper choice of material microstructure may be utilized to extend implant life.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Universal kinetics in reaction limited aggregation
2. Pad effects on material removal rate in chemical mechanical planarization
3. Fretting corrosion accelerates crevice corrosion of modular hip tapers10.1002/jab.770060104 ↗
4. Prediction of scratch generation in chemical mechanical planarization
5. Stress assisted dissolution of biomedical grade CoCrMo: influence of contact loads and residual stresses10.1016/j.cirp.2007.05.135 ↗
6. Surface evolution during the chemical mechanical planarization of copper10.1016/S0007-8506(07)60493-4 ↗
7. A scratch intersection model of material removal during chemical mechanical planarization (CMP)10.1115/1.1949616 ↗
8. Application of a fracture mechanics based life prediction method for contact fatigue10.1016/j.ijfatigue.2003.09.003 ↗
9. Material removal mechanisms in lapping and polishing10.1016/S0007-8506(07)60207-8 ↗
10. Normal indentation of elastic half space with a rigid frictionless axisymmetric punch10.1115/1.1445145 ↗
11. Aspects of equivalence between contact mechanics and fracture mechanics: theoretical connections and a life prediction methodology for fretting fatigue
12. Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method10.1002/(SICI)1097-4636(19971205)37:3<421::AID-JBM13>3.0.CO;2-E ↗
13. Contact of nominally flat surfaces
14. Differences in the fretting corrosion of metal–metal and ceramic-metal modular junctions of total hip replacements10.1016/S0736-0266(03)00186-4 ↗
15. Evaluation techniques of metallic biomaterials in vitro10.1016/S1468-6996(02)00028-1 ↗
16. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure charnley hip implants10.1002/jbm.1036 ↗
17. Johnson · 1985
18. On material removal mechanisms in finishing of advanced ceramics and glasses10.1016/S0007-8506(07)63113-8 ↗
19. Komulski, Marek, 2001. Chemical properties of material surfaces. New York.10.1201/9780367800482 ↗
20. Evolution of a surface-roughness spectrum caused by stress in nanometer-scale chemical etching10.1103/PhysRevLett.83.3872 ↗
21. Universality of fractal aggregates as probed by light scattering
22. Universal diffusion-limited colloid aggregation
23. Effects of abrasive size distribution in chemical mechanical planarization: modeling and verification
24. Metal fatigue — past, current and future
25. Onset of nanoscale wear of metallic implant materials: influence of surface residual stresses and contact loads10.1016/j.wear.2007.01.068 ↗
26. Mechanical load assisted dissolution of metallic implant surfaces: influence of contact loads and surface stress state10.1016/j.actbio.2007.08.004 ↗
27. Improvement of corrosion resistance in metallic biomaterials using a new electrical grinding technique10.1016/S0007-8506(07)61568-6 ↗
28. Ryu, J.J., 2008. Surface damage of metallic implant due to mechanical loading and chemical reactions. Ph.D. Thesis, Iowa State University.
29. Hip implants: paper V. physiological effects10.1016/j.matdes.2004.10.028 ↗
30. The role of fretting damage in total hip arthroplasty with modular design hip joints — evaluation of retrieval studies and experimental simulation methods
31. On fatigue crack growth in ductile materials by crack-tip blunting10.1016/j.jmps.2004.02.007 ↗
32. Overload effects in fatigue crack growth by crack-tip blunting10.1016/j.ijfatigue.2005.06.003 ↗
33. Effect of underload or overloads in fatigue crack growth by crack-tip blunting10.1016/j.engfracmech.2005.10.009 ↗
34. The effect of cathodic polarization on corrosion fatigue of a high strength steel in salt water, fatigue fract
35. Pad surface roughness and slurry particle size distribution effects on material removal rate in chemical mechanical planarization10.1016/S0007-8506(07)60110-3 ↗
36. Stress-dependent surface reactions and implications for a stress measurement technique