journal article·2010-11Open access

Tribological properties of Ti-based alloys in a simulated bone–implant interface with Ringer’s solution at fretting contacts

C.R. Ramos-Saenz, P.A. Sundaram, N. Diffoot-Carlo

Abstract

The wear properties of oxidized and non-oxidized gamma-TiAl (a potential biomaterial) as well as Ti-6Al-4V and CP-Ti disks were studied and characterized by means of standard wear tests using a custom made bone pin arrangement. The Ti-based disks were oxidized in air at 500 and 800 degrees C for one hour. The tribological properties of the oxides formed over the disks were studied using a linear reciprocating wear testing machine under both dry and simulated biological conditions using Ringer's solution. Loss of metal oxide and coefficient of friction values were determined from wear testing. From the results, abrasion and adhesion were the primary wear mechanisms in each of the three alloy-bone pairs. Specifically, the oxide formed on gamma-TiAl possessed the highest COF and wear resistance of the three materials which were studied. Also, as expected, bone wears down faster than the Ti-based metal oxide.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced materials and composites · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Adverse tissue reactions to wear particles from Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants10.1302/0301-620X.84B1.0840128 ↗
2. Tribological behavior of Ti-based alloys in simulated body fluid solution at fretting contacts10.1016/j.msea.2004.02.027 ↗
3. Chu · 2008
4. The surface science of titanium dioxide10.1016/S0167-5729(02)00100-0 ↗
5. Wear analysis of a retrieved hip implant with titanium nitride coating10.1016/S0883-5403(97)90164-9 ↗
6. Corrosion of metal orthopedic implants10.2106/00004623-199802000-00015 ↗
7. Uncemented porous-coated anatomic total hip replacement. Results in six years in a consecutive series10.1302/0301-620X.75B1.8421036 ↗
8. Sensitivity to titanium. A cause of implant failure?10.1302/0301-620X.73B1.1991768 ↗
9. Clinical aspects of osseointegration in joint replacement. A histological study of titanium implants10.1302/0301-620X.70B4.3403596 ↗
10. Sequential haematogenous infection of bilateral cementless total hip replacements10.1302/0301-620X.75B1.8421026 ↗
11. Exchange arthroplasty for infected knee replacements. A new two-stage method10.1302/0301-620X.75B1.8421028 ↗
12. Metal on metal hip resurfacing arthroplasty10.2106/JBJS.G.01012 ↗
13. Analysis of 118 second-generation metal-on-metal retrieved hip implants10.1302/0301-620X.81B1.0810046 ↗
14. Joint arthroplasty and prostheses10.1148/rg.235035059 ↗
15. The effects of particulate bone cements at the bone-implant interface10.1302/0301-620X.83B4.0830588 ↗
16. Metal wear and tissue response in failed titanium alloy total hip replacements10.1302/0301-620X.73B4.2071635 ↗