journal article·2010-11

Failure analysis of a total hip prosthesis implanted in active patient

M.A.L. Hernandez-Rodriguez, J.A. Ortega-Saenz, Geo R. Contreras-Hernandez

Publisher page

Abstract

This work presents an analysis of a total hip prosthesis that failed in service prematurely within 5 years. The prosthesis presented a fractured stem that was extracted from a 46 year old male patient, 75 kg weight and 1.76 m height. In order to determine the origin of the failure, the femoral stem component was analyzed by means of visual inspection; optical microscope (OM), scanning electronic microscopy (SEM) and energy disperse spectroscopy (EDS). The investigation showed that the crack had originated due to a high stress concentration on the anterolateral corner section of the stem. Any discontinuity or defect on the prosthesis surface in this location acted as preferential site to nucleate a crack which propagated by fatigue until the cross section was not able to sustain an eventual high load produced for the active patient.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. ASTM E1085-95, 2000. Test method for X-ray emission spectrometric analysis of low-alloy steels. American Society for Testing and Materials, West Conshohocken, PA.
2. ASTM E45-97, 2002. Standard test methods for determining the inclusion content of steel. American Society for Testing and Materials, West Conshohocken, PA.
3. ASTM E1019-03, 2003. Test methods for determination of carbon, sulfur, nitrogen, and oxygen in steel and in iron, nickel, and cobalt alloys. American Society for Testing and Materials, West Conshohocken, PA.
4. ASTM F138-03, 2003 Specification for wrought 18chromium-14nickel-2.5molybdenum stainless steel bar and wire for surgical implants. American Society for Testing and Materials, West Conshohocken, PA.
5. Ten-year survival of the MS-30 matt-surfaced cemented stem10.1302/0301-620X.87B7.16149 ↗
6. Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis: a 5 to 9 year retrospective study10.1016/S0883-5403(96)80001-5 ↗
7. Experience with the Exeter total hip replacement since
8. A method for shape optimization of a hip prosthesis to maximize the fatigue life of the cement10.1016/S1350-4533(96)00025-2 ↗
9. Importance of a thin cement mantle: autopsy studies of eight hips
10. Some aspects of the fatigue process in low carbon steels
11. Early fatigue failures of cemented, forged, cobalt–chromium femoral stems at the Neck–Shoulder junction eric10.1054/arth.2001.20542 ↗
12. Ling · 2004
13. The Thompson hemiarthroplasty, a new problem for an old favourite10.1302/0301-620X.88B7.17558 ↗
14. Cement microcracks in thin-mantle regions after in vitro fatigue loading10.1016/j.arth.2003.12.080 ↗
15. Stem fractures of extra-heavy cobra femoral hip prostheses10.1097/00003086-198411000-00023 ↗
16. Stanmore compared with Charnley total hip replacement: a prospective study of 413 arthroplasties10.1302/0301-620X.78B2.0780178 ↗
17. Fracture failure of a forged vitallium prosthesis10.2106/00004623-198264090-00012 ↗
18. Long-term results of Charnley total hip replacement, Review of 92 patients at 15 to 20 years10.1302/0301-620X.76B2.8113285 ↗
19. Force actions transmitted by joints in the human body
20. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses10.1016/j.jbiomech.2009.06.037 ↗
21. Survival of Lubinus straight (IP) and curved (SP) total hip prostheses in 543 patients after 4–13 years10.1007/BF00434092 ↗
22. Influence of grain size on work hardening and fatigue characteristics of alpha brass
23. The Exeter universal cemented femoral component at 8 to 12 years, a study of the first 325 hips10.1302/0301-620X.84B3.0840324 ↗
24. Fracture of the femoral stem of the Ring TCH hip prosthesis10.1302/0301-620X.74B5.1527122 ↗
25. Fatigue fracture of a forged cobalt–chromium-molybdenum femoral component inserted with cement. A report of ten cases10.2106/00004623-199712000-00010 ↗
26. Collarless polished tapered stem: clinical and radiological follow-up over 5 years10.1054/arth.2002.30292 ↗
27. Factors responsible for the sharp fatigue limit in iron and steel