journal article·2010-02Open access

The mechanical response of the ovine lumbar anulus fibrosus to uniaxial, biaxial and shear loads

J.P. Little, M.J. Pearcy, G. Tevelen, J.H. Evans, G. Pettet, C.J. Adam

Abstract

Analytical and computational models of the intervertebral disc (IVD) are commonly employed to enhance understanding of the biomechanics of the human spine and spinal motion segments. The accuracy of these models in predicting physiological behaviour of the spine is intrinsically reliant on the accuracy of the material constitutive representations employed to represent the spinal tissues. There is a paucity of detailed mechanical data describing the material response of the reinforced-ground matrix in the anulus fibrosus of the IVD. In the present study, the 'reinforced-ground matrix' was defined as the matrix with the collagen fibres embedded but not actively bearing axial load, thus incorporating the contribution of the fibre-fibre and fibre-matrix interactions. To determine mechanical parameters for the anulus ground matrix, mechanical tests were carried out on specimens of ovine anulus, under unconfined uniaxial compression, simple shear and biaxial compression. Test specimens of ovine anulus fibrosus were obtained with an adjacent layer of vertebral bone/cartilage on the superior and inferior specimen surface. Specimen geometry was such that there were no continuous collagen fibres coupling the two endplates. Samples were subdivided according to disc region - anterior, lateral and posterior - to determine the regional inhomogeneity in the anulus mechanical response. Specimens were loaded at a strain rate sufficient to avoid fluid outflow from the tissue and typical stress-strain responses under the initial load application and under repeated loading were determined for each of the three loading types. The response of the anulus tissue to the initial and repeated load cycles was significantly different for all load types, except biaxial compression in the anterior anulus. Since the maximum applied strain exceeded the damage strain for the tissue, experimental results for repeated loading reflected the mechanical ability of the tissue to carry load, subsequent to the initiation of damage. To our knowledge, this is the first study to provide experimental data describing the response of the 'reinforced-ground matrix' to biaxial compression. Additionally, it is novel in defining a study objective to determine the regionally inhomogeneous response of the 'reinforced-ground matrix' under an extensive range of loading conditions suitable for mechanical characterisation of the tissue. The results presented facilitate the development of more detailed and comprehensive constitutive descriptions for the large strain nonlinear elastic or hyperelastic response of the anulus ground matrix.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Musculoskeletal pain and rehabilitation · Automotive and Human Injury Biomechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Degeneration and aging affect the tensile behaviour of human lumbar annulus fibrosus10.1097/00007632-199512150-00010 ↗
2. Tensile properties of the anulus fibrosus i. The contribution of fibre–matrix interactions to tensile stiffness and strength10.1007/BF00299447 ↗
3. The resistance to flexion of the lumbar intervertebral joint10.1097/00007632-198005000-00007 ↗
4. Biomechanics and biochemistry of the intervertebral disks: The need for correlation studies10.1097/00003086-197711000-00015 ↗
5. Biaxial testing of human annulus fibrosus and its implications for a constitutive formulation10.1114/B:ABME.0000039357.70905.94 ↗
6. Frozen storage affects the compressive creep behavior of the porcine intervertebral disc10.1097/00007632-199712150-00009 ↗
7. Compressive mechanical properties of the human anulus fibrosus and their relationship to biochemical composition10.1097/00007632-199401001-00017 ↗
8. Frozen storage increases the ultimate compressive load of porcine vertebrae10.1002/jor.1100130522 ↗
9. Tensile properties of nondegenerate human lumbar annulus fibrosus10.1097/00007632-199602150-00009 ↗
10. Radial tensile properties of the lumbar annulus fibrosus are site and degeneration dependent10.1002/jor.1100150605 ↗
11. Anisotropic shear behaviour of the annulus fibrosus: Effect of harvest site and tissue prestrain10.1016/S1350-4533(00)00053-9 ↗
12. Load-displacement characteristics of articular cartilage10.1016/0020-7403(76)90044-8 ↗
13. Shear mechanical properties of human lumbar annulus fibrosus10.1002/jor.1100170517 ↗
14. Mechanical damage to the intervertebral disc annulus fibrosus subjected to tensile loading10.1016/j.jbiomech.2004.03.038 ↗
15. Degeneration affects the anisotropic and nonlinear behaviors of human anulus fibrosus in compression10.1016/S0021-9290(98)00046-3 ↗
16. Effect of strain rate on tensile properties of sheep disc anulus fibrosus10.3233/THC-2004-12405 ↗
17. Dynamics of human lumbar intervertebral joints. Experimental and finite-element investigations10.1097/00007632-199201000-00014 ↗
18. Functional differentiation in the spinal column10.1243/EMED_JOUR_1983_012_022_02 ↗
19. In vitro comparison of peak polymerisation temperatures of 5 provisional restoration resins
20. Little, J.P., 2004. Finite element modelling of anular lesions in the lumbar intervertebral disc. School of Mechanical, Manufacturing and Medical Engineering Queensland University of Technology. Brisbane, Australia. Doctor of Philosophy. http://adt.library.qut.edu.au./adt-qut/public/adt-QUT20050517.141125
21. Nonlinear finite element analysis of anular lesions in the l4/5 intervertebral disc10.1016/j.jbiomech.2007.01.007 ↗
22. Development of a biaxial compression device for biological samples: Preliminary experimental results for a closed cell foam10.1016/j.jmbbm.2008.10.011 ↗
23. Investigation of the laminate structure of lumbar disc anulus fibrosus10.1097/00007632-199005000-00011 ↗
24. The mechanical properties of collagen fibres: Stress–strain curves
25. Lumbar intradiscal pressure: Experimental studies on post-mortem material
26. Biomechanical time-tolerance of fresh cadaveric human spine specimens10.1002/jor.1100030305 ↗
27. The structural basis of interlamellar cohesion in the intervertebral disc wall10.1111/j.1469-7580.2006.00536.x ↗
28. Sheep lumbar intervertebral discs as models for human discs10.1016/S0268-0033(02)00009-8 ↗
29. Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method10.1016/j.jbiomech.2005.07.026 ↗
30. Issls prize winner: Microstructure and mechanical disruption of the lumbar disc annulus: Part i: A microscopic investigation of the translamellar bridging network10.1097/BRS.0b013e31817bb92c ↗
31. Mechanical response of a lumbar motion segment in axial torque alone and combined with compression10.1097/00007632-198611000-00012 ↗
32. Regional variation in tensile properties and biochemical composition of the human lumbar anulus fibrosus10.1097/00007632-199406000-00002 ↗
33. Regional variation in tensile properties and biochemical composition of the human lumbar anulus fibrosus10.1097/00007632-199406000-00002 ↗
34. Elastic fibers enhance the mechanical integrity of the human lumbar anulus fibrosus in the radial direction10.1007/s10439-007-9421-8 ↗
35. Defining the neutral zone of sheep intervertebral joints during dynamic motions: An in vitro study10.1016/S0268-0033(02)00180-8 ↗
36. Treloar · 1975
37. Theoretical model and experimental results for the nonlinear elastic behavior of human annulus fibrosus10.1016/j.orthres.2003.12.012 ↗
38. Are sheep spines a valid biomechanical model for human spines?10.1097/00007632-199710150-00009 ↗
39. Mechanical behavior of the human annulus fibrosus10.1016/0021-9290(76)90132-9 ↗
40. Elastic fibre organization in the intervertebral discs of the bovine tail10.1046/j.1469-7580.2002.00111.x ↗
41. Estimation of muscle forces in the lumbar spine during upper-body inclination10.1016/S0268-0033(00)00108-X ↗