journal article·2017-05

Why do some titanium-alloy total hip arthroplasty modular necks fail?

Samo K. Fokter, Andrej Moličnik, Rajko Kavalar, Primož Pelicon, Rebeka Rudolf, Nenad Gubeljak

Publisher page

Abstract

Background Increased modularity in total hip arthroplasty (THA) through extra junction between the neck and the femoral stem is gaining popularity among orthopaedic community. However, the advantage of the additional junction is shadowed by an increased risk of mechanical failure. The aim of this study was to describe the exact mechanism of fracture of the modular femoral neck in an uncemented stem. Methods Clinical, metallurgical, and mechanical analysis including finite-element modelling and elemental-sensitive tissue analysis with the micro-PIXE method was performed on two patients treated with fully modular primary THA made from Titanium alloy of the same oval taper-cone design. In patient A revision was performed 7.8 years after the unilateral primary procedure because of modular femoral neck fracture, while patient B was left-side revised 15 years after the bilateral primary procedure because of aseptic loosening of the femoral stem. Results Body weight was 30% higher and the arm of implanted modular femoral neck was 51% longer in patient A compared to patient B. Therefore, the stress ratio on the modular femoral neck of patient A was calculated to be 2.45 times higher than in patient B, preventing cold welding and producing taper damage and degradation at the neck-stem junction. Large clusters of metallic debris containing Titanium and Vanadium from the alloy were present in the periprosthetic soft tissues of patient A. Conclusions Patients with higher body mass index treated with fully modular Ti-alloy THA may be at increased risk to experience catastrophic failure of the device. Orthopaedic surgeons should avoid using long necks whenever possible, as these are especially prone to develop a vicious circle starting with the fretting process and crevice corrosion at the taper-cone connection, leading to crack initiation and crack propagation, accelerated by the increased vulnerability of the Ti-alloy in biologic media, ultimately ending as fracture at the typical site. Serum Ti concentration may represent a rough estimation of taper degradation and patients with elevated levels should be warned and followed accordingly.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Anatomic cementless total hip arthroplasty with ceramic bearings and modular necks: 3–5 years follow-up
2. Corrosion-induced fracture of a double-modular hip prosthesis: a case report10.2106/JBJS.I.00980 ↗
3. Microstructural morphology effects on fracture resistance and crack tip strain distribution in Ti–6Al–4V alloy for orthopedic implants10.1016/j.matdes.2013.07.097 ↗
4. Failure of the modular neck in a total hip arthroplasty10.1016/j.arth.2009.07.015 ↗
5. Fracture of the modular femoral neck component in total hip arthroplasty10.1016/j.arth.2011.05.024 ↗
6. Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys10.1016/j.ijfatigue.2009.09.009 ↗
7. Titanium alloy femoral neck fracture-clinical and metallurgical analysis in 6 cases
8. Garellick, Göran, Kärrholm, Johan, Rogmark, Cecilia, Roberts, P., 2008. Swedish Hip Arthroplasty Register Annual Report. Published 2009 〈www.shpr.se.〉 (accessed 24.06.16)
9. Serum metal ions with a titanium modular neck total hip replacement system10.1016/j.arth.2015.04.040 ↗
10. Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material10.1186/1471-2474-11-3 ↗
11. The innovation trap10.3109/17453674.2016.1146511 ↗
12. Total hip arthroplasty-related osteogenic osteosarcoma: case report and review of the literature10.1186/s40001-016-0203-3 ↗
13. Keppler, L., Cameron, HU., Mctighe, T., 2006. The role of modularity in primary THA - Is there one? In: Proceedings of the AAOS Annual Meeting, Scientific Exhibit, Chichago, March 22–26
14. Role of plastic deformation and microstructure in the micro-electrochemical behaviour of Ti-6Al-4V in sodium chloride solution10.1016/j.electacta.2012.12.029 ↗
15. Modular neck femoral stems10.1302/0301-620X.95B8.31525 ↗
16. Microstructure and materials properties of titanium alloys
17. The anatomic basis for the concept of lateralized femoral stems: a frontal plane radiographic study of the proximal femur10.1016/S0883-5403(00)91337-8 ↗
18. Primary hip replacement stem taper fracture due to corrosion in 3 patients10.3109/17453674.2015.1128780 ↗
19. In vivo serum titanium ion levels following modular neck total hip arthroplasty--10 year results in 67 patients10.1016/j.actbio.2012.12.001 ↗
20. Failure analysis of three uncemented titanium-alloy modular total hip stems10.1016/j.engfailanal.2010.02.011 ↗
21. Brief exposure to copper activates lysosomal exocytosis10.1016/j.ceca.2015.01.005 ↗
22. Total hip arthroplasty modular neck failure10.1016/j.arth.2010.03.011 ↗
23. Sex differences in hip morphology: is stem modularity effective for total hip replacement?10.2106/JBJS.I.00533 ↗
24. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe10.1016/j.nimb.2015.01.063 ↗
25. Early failure of a modular femoral neck total hip arthroplasty component: a case report10.2106/JBJS.I.01107 ↗
26. Fracture of a modular femoral neck after total hip arthroplasty: a case report10.2106/JBJS.I.01033 ↗