journal article·2019-03

Bacterial leakage and bending moments of screw-retained, composite-veneered PEEK implant crowns

Andreas Wachtel, Tycho Zimmermann, Mona Sütel, Ufuk Adali, Mohamad Abou-Emara, Wolf-Dieter Müller, Sven Mühlemann, Andreas Dominik Schwitalla

Publisher page

Abstract

Due to its elastic modulus close to bone, the high-performance material PEEK (polyetheretherketone) represents an interesting material for implant-supported dental prostheses. Besides a damping effect of masticatory forces, it might have a sealing effect against bacterial leakage of the implant-abutment interface (IAI). So far, PEEK has only been used for provisional implant crowns. Therefore, the aim of the study was the evaluation of the bacterial tightness of screw-retained PEEK crowns on titanium implants with conical IAI during masticatory simulation and subsequent bending moment testing. Ten screw-retained implant crowns in the shape of an upper central incisor consisting of a PEEK crown framework veneered with composite were connected to NobelActive RP titanium implants (4.3 × 11.5 mm, Nobel Biocare AB, Göteborg, Sweden) with a tightening torque of 15 Ncm. Prior to tightening, the interior of the implant was inoculated with a bacterial suspension of Enterococcus faecium. The specimens were overmolded with indicating agar (Kanamycin-Aesculin-Azid-Agar (KAAA), Oxoid Limited, Basingstoke United Kingdom), that turns black in contact with E. faecium. The specimens were subjected to a cyclic masticatory simulation whereby a force of 50 N cm was applied at an angle of 30° to the implant axis for 1.2 million cycles. Afterwards, the specimens were subjected to a static loading test according to ISO 14801:2007 to determine the bending moment. During masticatory simulation neither a loosening of the implant screws nor any damage to the veneer or the PEEK framework occurred. Furthermore, no bacterial leakage could be observed in any of the specimens. The average maximum bending moment was measured at 352.13 ± 48.96 N cm. Regarding masticatory forces, PEEK implant crowns seem to be applicable as definitive implant-supported restorations. Furthermore, the bacterial tightness of the IAI of screw-retained one-piece PEEK implant crowns is advantageous compared to superstructures of conventional materials. Further studies are necessary to substantiate the clinical significance of these findings.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Use of high performance polymers as dental implant abutments and frameworks: a case series report
2. Impact of the heating/quenching process on the mechanical, optical and thermodynamic properties of polyetheretherketone (PEEK) films10.1016/j.dental.2017.09.016 ↗
3. DNA probe identification of bacteria colonizing internal surfaces of the implant-abutment interface: a preliminary study10.1902/jop.2005.76.1.115 ↗
4. The genus Enterococcus
5. In vitro cytotoxicity evaluation of elemental ions released from different prosthodontic materials10.1016/j.dental.2009.07.008 ↗
6. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis10.1046/j.0909-8836..t01-6-.x ↗
7. Single tooth bite forces in healthy young adults10.1046/j.0305-182X.2003.01179.x ↗
8. Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review10.1007/s10006-015-0494-5 ↗
9. Biofilm formation on the surface of modern implant abutment materials10.1111/clr.12454 ↗
10. Discoloration of the mucosa caused by different restorative materials - a spectrophotometric in vitro study10.1111/clr.12928 ↗
11. Internal bacterial colonization of implants: association with peri-implant bone loss10.1111/clr.12421 ↗
12. Biomechanical, histological, and computed X-ray tomographic analyses of hydroxyapatite coated PEEK implants in an extended healing model in rabbit10.1002/jbm.a.36345 ↗
13. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study10.1016/j.prosdent.2017.03.008 ↗
14. Microleakage of the prosthetic abutment/implant interface with internal and external connection: in vitro study10.1111/clr.12217 ↗
15. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck10.1016/j.archoralbio.2017.07.022 ↗
16. Damping behavior of implant-supported restorations10.1111/j.1600-0501.2011.02311.x ↗
17. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up10.1111/clr.12439 ↗
18. Microleakage at the different implant abutment interface: a systematic review
19. Streptococci of lancefield groups A, B and D and those of buccal origin in foods: their public health significance, monitoring and control
20. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging10.1111/clr.12192 ↗
21. Bone remodeling around implants with external hexagon and morse-taper connections: a randomized, controlled, split-mouth, clinical trial10.1111/cid.12437 ↗
22. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: a study on the titanium resin base concept10.1111/clr.13139 ↗
23. Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation10.1111/j.1600-0501.2010.02141.x ↗
24. A novel approach to prove bacterial leakage of implant-abutment connections in vitro10.1563/aaid-joi-D-16-00065 ↗
25. Scanning electron microscopy of intact colonies of microorganisms10.1128/jb.104.2.902-909.1970 ↗
26. Polyetheretherketone overlay prosthesis over high noble ball attachments to overcome base metal sensitivity: a clinical report10.1111/jopr.12747 ↗
27. The all-on-4 modified polyetheretherketone treatment approach: a clinical report10.1016/j.prosdent.2017.04.020 ↗