journal article·2015-01

Modeling the biomechanical and injury response of human liver parenchyma under tensile loading

Costin D. Untaroiu, Yuan-Chiao Lu, Sundeep K. Siripurapu, Andrew R. Kemper

Publisher page

Abstract

The rapid advancement in computational power has made human finite element (FE) models one of the most efficient tools for assessing the risk of abdominal injuries in a crash event. In this study, specimen-specific FE models were employed to quantify material and failure properties of human liver parenchyma using a FE optimization approach. Uniaxial tensile tests were performed on 34 parenchyma coupon specimens prepared from two fresh human livers. Each specimen was tested to failure at one of four loading rates (0.01s(-1), 0.1s(-1), 1s(-1), and 10s(-1)) to investigate the effects of rate dependency on the biomechanical and failure response of liver parenchyma. Each test was simulated by prescribing the end displacements of specimen-specific FE models based on the corresponding test data. The parameters of a first-order Ogden material model were identified for each specimen by a FE optimization approach while simulating the pre-tear loading region. The mean material model parameters were then determined for each loading rate from the characteristic averages of the stress-strain curves, and a stochastic optimization approach was utilized to determine the standard deviations of the material model parameters. A hyperelastic material model using a tabulated formulation for rate effects showed good predictions in terms of tensile material properties of human liver parenchyma. Furthermore, the tissue tearing was numerically simulated using a cohesive zone modeling (CZM) approach. A layer of cohesive elements was added at the failure location, and the CZM parameters were identified by fitting the post-tear force-time history recorded in each test. The results show that the proposed approach is able to capture both the biomechanical and failure response, and accurately model the overall force-deflection response of liver parenchyma over a large range of tensile loadings rates.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Automotive and Human Injury Biomechanics · Elasticity and Material Modeling · High-Velocity Impact and Material Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Identification of occupant posture using a bayesian classification methodology to reduce the risk of injury in a collision10.1016/j.trc.2011.06.006 ↗
3. A human model for road safety: from geometrical acquisition to model validation with Radioss10.1080/10255840310001606080 ↗
4. Measurement of mixed-mode delamination fracture toughness of unidirectional glass/epoxy composites with mixed-mode bending apparatus10.1016/0266-3538(96)00005-X ↗
5. Cohesive zone modeling of mode I tearing in thin soft materials10.1016/j.jmbbm.2013.07.015 ↗
6. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure10.1016/j.jbiomech.2010.03.038 ↗
7. Computational modeling of impact damage in brittle materials10.1016/0020-7683(95)00255-3 ↗
8. Hardening cohesive/overlapping zone model for metallic materials: the size-scale independent constitutive law10.1016/j.engfracmech.2011.11.021 ↗
9. Transversely isotropic properties of porcine liver tissue: experiments and constitutive modeling10.1007/s11517-006-0137-y ↗
10. Modern topics and challenges in dynamic fracture10.1016/j.jmps.2004.09.002 ↗
11. Estimating zero-strain states of very soft tissue under gravity loading using digital image correlation10.1016/j.media.2009.11.002 ↗
12. Constitutive modeling of liver tissue: experiment and theory10.1007/s10439-009-9812-0 ↗
13. A general bilinear fit for the softening curve of concrete10.1007/BF02472827 ↗
14. Hallquist, J.O., 2006. In: LS-DYNA Theory Manual, LSTC
15. Contribution of age and gender to outcome of blunt splenic injury in adults: multicenter study of the eastern association for the surgery of trauma10.1097/00005373-200111000-00010 ↗
16. Mechanical characterization of the liver capsule and parenchyma
17. Kinematics of the thoraco–abdominal contents under various loading scenarios
18. Quantifying dynamic mechanical properties of human placenta tissue using optimization techniques with specimen-specific finite-element models10.1016/j.jbiomech.2009.07.003 ↗
19. A stochastic visco-hyperelastic model of human placenta tissue for finite element crash simulations10.1007/s10439-010-0222-0 ↗
20. Mechanisms of blunt liver trauma patterns: an analysis of 53 cases10.3892/etm.2012.837 ↗
21. Kanninen · 1985
22. Biomechanical response of human liver in tensile loading
23. Effect of strain rate on the material properties of human liver parenchyma in unconfined compression10.1115/1.4024821 ↗
24. Effects of perfusion on the viscoelastic characteristics of liver10.1016/j.jbiomech.2005.07.005 ↗
25. A tabulated formulation of hyperelasticity with rate effects and damage10.1007/s00466-006-0150-x ↗
26. Effect of storage methods on indentation-based material properties of abdominal organs due to tissue storage methods10.1177/0954411912468558 ↗
27. Statistical modeling of human liver incorporating the variations in shape, size, and material properties
28. Effect of storage on tensile material properties of bovine liver10.1016/j.jmbbm.2013.09.022 ↗
29. Influence of boundary conditions, specimen geometry and material heterogeneity on model calibration from triaxial tests10.1002/nag.833 ↗
30. Numerically determined enrichment functions for the extended finite element method and applications to bi-material anisotropic fracture and polycrystals10.1002/nme.2858 ↗
31. Nahum · 2002
32. Finite-deformation irreversible cohesive elements for three-dimensional crack-propagation analysis10.1002/(SICI)1097-0207(19990330)44:9<1267::AID-NME486>3.0.CO;2-7 ↗
33. Error estimation and adaptivity for discontinuous failure10.1002/nme.2495 ↗
34. Cohesive zone models: a critical review of traction–separation relationships across fracture surfaces10.1115/1.4023110 ↗
35. Rainsberger · TrueGrid User’s Manual · 2006
36. Anthropometric dependence of the response of a Thorax FE model under high speed loading: validation and real world accident replication10.1016/j.cmpb.2012.11.004 ↗
37. Anatomic variation in the elastic inhomogeneity and anisotropy of human femoral cortical bone tissue is consistent across multiple donors10.1016/j.jbiomech.2011.04.009 ↗
38. Freezing affects the mechanical properties of bovine liver
39. The effect of temperature on the mechanical properties of bovine liver
40. Blunt liver injury with intact ribs under impacts on the abdomen: a biomechanical investigation
41. Strain-rate dependent material properties of the porcine and human kidney capsule10.1016/j.jbiomech.2004.05.036 ↗
42. Using pressure to predict liver injury risk from blunt impact
43. Effect of fiber debonding in a whisker-reinforced metal10.1016/0921-5093(90)90170-8 ↗
44. The relation between crack-growth resistance and fracture process parameters in elastic plastic solids10.1016/0022-5096(92)90020-3 ↗
45. The influence of plasticity on mixed-mode interface toughness10.1016/0022-5096(93)90057-M ↗
46. Experimental mechanical characterization of abdominal organs: liver, kidney & spleen10.1016/j.jmbbm.2012.07.010 ↗
47. The influence of the specimen shape and loading conditions on the parameter identification of a viscoelastic brain model10.1155/2013/460413 ↗
48. Performance-based classification of occupant posture to reduce the risk of injury in a collision10.1109/TITS.2012.2223687 ↗
49. Material characterization of liver parenchyma using specimen-specific finite element models10.1016/j.jmbbm.2013.05.013 ↗
50. Lateral Impact Validation of a Geometrically Accurate Full Body Finite Element Model for Blunt Injury Prediction10.1007/s10439-012-0684-3 ↗
51. Yamada · 1970
52. Influence of specimen dimensions on the tensile behavior of ultrafine-grained Cu10.1016/j.scriptamat.2008.05.031 ↗