Characterization methods of bone–implant-interfaces of bioresorbable and titanium implants by fracture mechanical means
Source abstract
Abstract
Bioresorbable materials for implants have become increasingly researched over the last years. The bone-implant-interfaces of three different implant materials, namely a new bioresorbable magnesium alloy, a new self-reinforced polymer implant and a conventional titanium alloy, were tested using various methods: push-out tests, SEM and EDX analyses as well as surface analyses based on stereoscopic 3D pictures were conducted. The fracture energy is proposed as a very significant reference value for characterizing the mechanical performance of a bone-implant system. By using a video-extensometer system instead of, as is commonly done, tracking the movement of the crosshead in the push-out tests, the accuracy of measurement could be increased.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Treatment of pediatric facial fractures: the case for metallic fixation10.1016/j.joms.2004.11.010 ↗
2. In vivo low-density bone apposition on different implant surface materials10.1016/j.ijom.2008.12.016 ↗
3. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat10.1016/S0142-9612(97)00018-5 ↗
4. An in-vivo method for biomechanical characterization of bone-anchored implants10.1016/S1350-4533(98)00023-X ↗
5. Castellani, C., Lindtner, R.A., Hausbrandt, P., Tschegg, E., Stanzl-Tschegg, S.E., Zanoni, G., Beck, S., Weinberg, A.M., 2010. Bone–implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control. Acta Biomaterialia (in press).10.1016/j.actbio.2010.08.020 ↗
6. Significance of peak value and duration of the interfacial shear load in evaluation of the bone–implant interface10.1016/S0268-0033(03)00138-4 ↗
7. Influence of implant location on the mechanical characteristics using the transcortical model10.1002/jbm.820290119 ↗
8. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants
9. Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation10.1016/S1350-4533(02)00027-9 ↗
10. Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone10.1016/S0142-9612(02)00548-3 ↗
11. Holzlechner, G., 2008. Scherfestigkeiten von Knochen und Implantaten. Baccalaureate Paper. Vienna University of Technology, Vienna.
12. Biodegradable pin fixation of elbow fractures in children. A randomised trial
13. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
14. Lindtner, R.A., 2009. Biomechanical and radiological evaluation of the bone–implant interface of new biodegradable implants in comparison to conventional titanium pins. Diploma Thesis. Medizinische Universität Graz, Graz.
15. Mechanical evaluation of implanted calcium phosphate cement incorporated with PLGA microparticles10.1016/j.biomaterials.2006.05.022 ↗
16. Bone attachment to glass–fibre-reinforced composite implant with porous surface10.1016/j.actbio.2009.01.020 ↗
17. Effects of surface treatments on high cycle corrosion fatigue of metallic implant materials10.1016/S0142-1123(00)00057-8 ↗
18. Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits
19. Maximizing results in craniofacial surgery with bioresorbable fixation devices10.1097/scs.0b013e3180a771e9 ↗
20. A new electrochemically graded hydroxyapatite coating for osteosynthetic implants promotes implant osteointegration in a rat model10.1002/jbm.10130 ↗
21. The effects of nail rigidity on fracture healing in rats with osteoporosis10.1080/17453670902807490 ↗
22. The potential for bioresorbable implants in paediatric fractures10.1016/S0020-1383(02)00137-7 ↗
23. On the mechanisms of biocompatibility10.1016/j.biomaterials.2008.04.023 ↗
24. Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K.U., Willumeit, R., Feyerabend, F., (2008). Degradable biomaterials based on magnesium corrosion. Current Opinion in Solid State and Materials Science. 12. pp. 63–72.10.1016/j.cossms.2009.04.001 ↗
25. In vivo biocompatibility and mechanical study of novel bone-bioactive materials for prosthetic implantation10.1002/(SICI)1097-4636(199908)46:2<279::AID-JBM18>3.0.CO;2-M ↗