Performance of QCT-Derived scapula finite element models in predicting local displacements using digital volume correlation
Source abstract
Abstract
Subject-specific finite element models (FEMs) of the shoulder complex are commonly used to predict differences in internal load distribution due to injury, treatment or disease. However, these models rely on various underlying assumptions, and although experimental validation is warranted, it is difficult to obtain and often not performed. The goal of the current study was to quantify the accuracy of local displacements predicted by subject-specific QCT-based FEMs of the scapula, compared to experimental measurements obtained by combining digital volume correlation (DVC) and mechanical loading of cadaveric specimens within a microCT scanner. Four cadaveric specimens were loaded within a microCT scanner using a custom-designed six degree-of-freedom hexapod robot augmented with carbon fiber struts for radiolucency. BoneDVC software was used to quantify full-field experimental displacements between pre- and post-loaded scans. Corresponding scapula QCT-FEMs were generated and three types of boundary conditions (BC) (idealized-displacement, idealized-force, and DVC-derived) were simulated for each specimen. DVC-derived BCs resulted in the closest match to the experimental results for all specimens (best agreement: slope ranging from 0.87 to 1.09; highest correlation: r2 ranging from 0.79 to 1.00). In addition, a two orders of magnitude decrease was observed in root-mean-square error when using QCT-FEMs with simulated DVC-derived BCs compared to idealized-displacement and idealized-force BCs. The results of this study demonstrate that scapula QCT-FEMs can accurately predict local experimental full-field displacements if the BCs are derived from DVC measurements.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shoulder Injury and Treatment · Cardiac Valve Diseases and Treatments · Shoulder and Clavicle Injuries
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Posterior augmented glenoid implants require less bone removal and generate lower stresses: a finite element analysis10.1016/j.jse.2015.10.003 ↗
2. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
3. Finite element modeling mesh quality, energy balance and validation methods: a review with recommendations associated with the modeling of bone tissue10.1016/j.jbiomech.2013.03.022 ↗
4. Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study10.1016/j.jmbbm.2016.09.014 ↗
5. Uncertainties of synchrotron microCT-based digital volume correlation bone strain measurements under simulated deformation10.1016/j.jbiomech.2019.01.041 ↗
6. Micro Finite Element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
7. Unveiling 3D deformations in polymer composites by coupled micro X-ray computed tomography and volumetric digital image correlation10.1007/s11340-016-0140-7 ↗
8. Quantifying the three-dimensional damage and stress redistribution mechanisms of braided SiC/SiC composites by in situ volumetric digital image correlation10.1016/j.scriptamat.2016.12.021 ↗
9. Damage mechanisms in elastomeric foam composites: multiscale X-ray computed tomography and finite element analyses10.1016/j.compscitech.2018.11.025 ↗
10. Verified and validated finite element analyses of humeri10.1016/j.jbiomech.2016.02.036 ↗
11. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
12. Precision of digital volume correlation approaches for strain analysis in bone imaged with micro-computed tomography at different dimensional levels
13. Real-time FPGA control of a hexapod robot for 6-DOF biomechanical testing
14. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
15. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
16. Extracting accurate strain measurements in bone mechanics: a critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
17. Development and experimental validation of a three-dimensional finite element model of the human scapula10.1243/095441104322984022 ↗
18. Differences in trabecular microarchitecture and simplified boundary conditions limit the accuracy of quantitative computed tomography-based finite element models of vertebral failure10.1115/1.4038609 ↗
19. Accuracy of finite element analyses of CT scans in predictions of vertebral failure patterns under axial compression and anterior flexion10.1016/j.jbiomech.2015.12.004 ↗
20. Development of a validated glenoid trabecular density-modulus relationship10.1016/j.jmbbm.2018.10.013 ↗
21. Adaptive velocity-based six degree of freedom load control for real-time unconstrained biomechanical testing10.1016/j.jbiomech.2014.06.023 ↗
22. In situ observation of fracture behavior of canine cortical bone under bending10.1016/j.msec.2016.01.061 ↗
23. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
24. Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: tissue modulus assignment and sensitivity analyses10.1016/j.jmbbm.2019.03.008 ↗
25. Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture10.1016/j.jmbbm.2018.05.016 ↗
26. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
27. Validation of finite element models of the mouse tibia using digital volume correlation10.1016/j.jmbbm.2018.06.022 ↗
28. Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: an organ-level study10.1016/j.jbiomech.2016.10.018 ↗
29. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
30. On the dependence of the elasticity and strength of cancellous bone on apparent density10.1016/0021-9290(88)90008-5 ↗
31. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
32. Stiffness of compact bone: effects of porosity and density10.1016/0021-9290(88)90186-8 ↗
33. NIH Image to ImageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
34. Digital volume correlation and micro-CT: an in-vitro technique for measuring full-field interface micromotion around polyethylene implants10.1016/j.jbiomech.2015.05.024 ↗
35. Bone–cement interface of the glenoid component: stress analysis for varying cement thickness10.1016/j.clinbiomech.2005.03.010 ↗
36. New methodology for multi-dimensional spinal joint testing with a parallel robot10.1007/s11517-006-0158-6 ↗
37. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements10.1115/1.2146001 ↗
38. Finite element models of the human shoulder complex: a review of their clinical implications and modelling techniques: finite Element Models of Human Shoulder Complex10.1002/cnm.2777 ↗
39. 3D full-field mechanical measurement of a shoulder bone under implant loading