Development of a synovial fluid analogue with bio-relevant rheology for wear testing of orthopaedic implants
Source abstract
Abstract
The rheological properties of synovial fluid (SF) are crucial to the performance of joint prostheses. During the development of joint prostheses, wear tests are performed, which simulate joint movements in diluted solutions (usually between 25 and 33% v/v) of bovine serum which has very different rheological properties compared with native SF, where rheology is maintained by hyaluronan. Consequently, there is a need to develop a more suitable artificial SF. In this study, we used rheological techniques to understand SF flow properties which provided an insight into the mechanical behaviour required of a practical SF analogue. Steady-shear viscosity measurements were performed to reveal changes as a function of shear rate. To analyse the viscoelastic properties small deformation oscillatory measurements of storage modulus (G') loss modulus (G″) and complex viscosity (η(⁎)) were made. The rheological properties of the SF where compared with those of the polysaccharides sodium alginate, gellan gum and mixtures of both polymers. Initial results revealed classic shear thinning behaviour for the SF with a small Newtonian plateau at low shear rates with a gradual reduction in viscosity with increasing shear rate. Viscoelasticity measurements also showed that at low frequencies of oscillation there was a viscous response with G″ greater than G' and at higher frequencies there was an elastic response. Rheological properties were found to be similar to that of a 50:50 mix of 2% w/v high molecular weight alginate and 0.75% w/v gellan gum. Importantly, the lubricating behaviour of the serum differed significantly from the biopolymer blend over a full range of sliding velocities. The biopolymer blend was shown to lubricate the opposing surfaces more effectively. This difference was attributed to the more rapid alignment of the polysaccharide during shear when compared with the bovine albumin (the most abundant protein in serum), which typically exhibits a globular structure and has a tendency for self-association. These results suggest that polysaccharide solutions with bio-relevant rheology maybe be suitable as lubricants for in vitro orthopaedic prosthetic wear tests.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. The Physical properties of synovial fluid and the special role of hyaluronic acid
2. The pathology of total joint arthroplasty10.1007/s002560050552 ↗
3. Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations10.1243/0954411001535543 ↗
4. Rheological study of viscosupplements and synovial fluid in patients with osteoarthritis10.5405/jmbe.834 ↗
5. Content and composition of glycosaminoglycans in human knee joint cartilage: variation with site and age in adults10.3109/03008207509152172 ↗
6. Cation Interactions in Gellan – An X-Ray Study of the Potassium Salt10.1016/0008-6215(88)84020-5 ↗
7. Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant10.1243/09544119JEIM30 ↗
8. Rapid purification of commercial gellan gum to highly soluble and gellable monovalent cation salts10.1016/S0144-8617(96)00168-3 ↗
9. Rheological properties of synovial fluids
10. Rheological study of synovial fluid obtained from dogs: healthy, pathological, and post-surgery, after spontaneous rupture of cranial cruciate ligament10.1007/s10439-009-9832-9 ↗
11. Challenges associated with using bovine serum in wear testing orthopaedic biopolymers10.1177/0954411911416047 ↗
12. Holzwarth, U., Cotogno, G., 2012 Total Hip Arthroplasty: State of the Art, Challenges and Prospects. JRC Scientific and Policy Reports, European Commission, doi:10.2788/31286.
13. ISO. 14242-1 International Standard 2002, Implants for Surgery—Wear of Total Hip Joint Prostheses Part 1, Loading and Displacement Parameters for Wear Testing Machines and Corresponding Environmental Conditions for Test. International Organization for Standardization, Geneva, Switzerland.
14. Wear tests of orthopaedic biopolymers with the biolubricant augmented by a visco-supplement10.1243/13506501JET480 ↗
15. rheological and tribologal investigation on sodium alginate as synthetic synovial fluid
16. Mazzucco, D., 2003 Variation of Joint Fluid Composition and its Effect on the Tribology of Replacement Joint Articulation. Ph.D. Thesis. Massachusetts Institute of Technology.
17. Identification and characterization of polymeric and metallic wear debris from periprosthetic tissues after total hip revision surgery10.1615/JLongTermEffMedImplants.v21.i4.30 ↗
18. Viscoelastic properties of normal human synovia and their relation to biomechanics
19. Richter, B.I., Ostermeier, S., Turger, A., Denkena, B., Hurschler, C. 2010 A Rolling-gliding Wear Simulator for the Investigation of Tribological Material Pairings for Application in Total Knee Arthroplasty.BioMedical Engineering OnLine 9, 24.10.1186/1475-925X-9-24 ↗
20. A hip wear simulator with 100 test stations10.1243/095441105X34301 ↗
21. An initial evaluation of gellan gum as a material for tissue engineering applications10.1177/0885328207076522 ↗
22. Biological effects of wear particles generated in total joint replacements: trends and future prospects10.1179/1751584X12Y.0000000005 ↗
23. Design and wear testing of a temporomandibular joint prosthesis articulation10.1177/00220345000790020401 ↗
24. The effects of lubricant composition on in vitro wear testing of polymeric acetabular components10.1002/jbm.b.10077 ↗
25. Biological responses to and toxicity of nanoscale implant materials
26. Thermal aggregation of bovine serum albumin studied by asymmetrical flow field-flow fractionation10.1016/j.aca.2010.07.016 ↗