journal article·2015-01

Variation in the human ribs geometrical properties and mechanical response based on X-ray computed tomography images resolution

Rafał Perz, Jacek Toczyski, Damien Subit

Publisher page

Abstract

Computational models of the human body are commonly used for injury prediction in automobile safety research. To create these models, the geometry of the human body is typically obtained from segmentation of medical images such as computed tomography (CT) images that have a resolution between 0.2 and 1mm/pixel. While the accuracy of the geometrical and structural information obtained from these images depend greatly on their resolution, the effect of image resolution on the estimation of the ribs geometrical properties has yet to be established. To do so, each of the thirty-four sections of ribs obtained from a Post Mortem Human Surrogate (PMHS) was imaged using three different CT modalities: standard clinical CT (clinCT), high resolution clinical CT (HRclinCT), and microCT. The images were processed to estimate the rib cross-section geometry and mechanical properties, and the results were compared to those obtained from the microCT images by computing the 'deviation factor', a metric that quantifies the relative difference between results obtained from clinCT and HRclinCT to those obtained from microCT. Overall, clinCT images gave a deviation greater than 100%, and were therefore deemed inadequate for the purpose of this study. HRclinCT overestimated the rib cross-sectional area by 7.6%, the moments of inertia by about 50%, and the cortical shell area by 40.2%, while underestimating the trabecular area by 14.7%. Next, a parametric analysis was performed to quantify how the variations in the estimate of the geometrical properties affected the rib predicted mechanical response under antero-posterior loading. A variation of up to 45% for the predicted peak force and up to 50% for the predicted stiffness was observed. These results provide a quantitative estimate of the sensitivity of the response of the FE model to the resolution of the images used to generate it. They also suggest that a correction factor could be derived from the comparison between microCT and HRclinCT images to improve the response of the model developed based on HRclinCT images.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Autopsy Techniques and Outcomes · Automotive and Human Injury Biomechanics · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. AAAM AIS, 2008. Abbreviated Injury Scale (AIS) 2005—Update 2008. Association for the Advancement of Automotive Medicine.
2. A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding, and element characteristics10.1080/15389581003709902 ↗
3. Morphologic characteristics of Korean Elderly Rib
4. H.Y. Choi, I.H. Lee, 2009. Thorax FE model for older population. In: Proceedings of the Joint Symposium of Sports Engineering and Human Dynamics Symposium, The Japan Society of Mechanical Engineers (JSME) Fukuoka.10.1299/jsmesports.2009.0_367 ↗
5. BoneJ: free and extensible bone image analysis in Image J10.1016/j.bone.2010.08.023 ↗
6. GHBMC Official Webpage: 〈http://www.ghbmc.com/〉.
7. Frontal thoracic response to dynamic loading: the role of superficial tissues, viscera and the rib cage10.1080/13588260801933725 ↗
8. Development of a three-dimensional finite element chest model for the 5th percentile female
9. Effect of assumed stiffness and mass density on the impact response of the human chest using a three-dimensional FE model of the human body10.1115/1.2264394 ↗
10. Kindig, M.2009. Tolerance to Failure and Geometric Influenced on the Stiffness of Human Ribs Under Anterior–Posterior Loading. Thesis for the Degree of M.Sc. in Mechanical Engineering, School of Engineering and Applied Science, University of Virginia, Charlottesville, Virginia, USA.
11. Kindig, M., Zuoping, L., Kent, R., Subit, D.2013. Effect of intercostal muscle and costovertebral joint material properties on human ribcage stiffness and kinematics, Computer Methods in Biomechanics and Biomedical Engineering, in press10.1080/10255842.2013.820718 ↗
12. Kroell, C., Schneider, D., Nahum, A.1974. In: Impact Tolerance and Response of the Human Thorax II Proceedings of the 18th Stapp Car Crash Conference, SAE Paper.10.4271/741187 ↗
13. Rib fractures under anterior-posterior dynamic loads: experimental and finite element study10.1016/j.jbiomech.2009.08.040 ↗
14. Influence of mesh density, cortical thickness and material properties on human rib fracture prediction10.1016/j.medengphy.2010.06.015 ↗
15. Development of a 3D finite element model of the human body
16. Geometry of human ribs pertinent to orthopedic chest-wall reconstruction10.1016/j.jbiomech.2006.05.017 ↗
17. Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections10.1016/8756-3282(95)00489-0 ↗
18. Robin, S., 2001. Human model for safety: a joint effort towards the development of refined human-like car occupant models. In: Proceedings of the 17th International Technical Conference on the Enhanced Safety Vehicle. Paper 297.
19. Sandoz B, Zidelkeir Z, Badina A, Bermond F, Mitton D, Skalli W., 2013. Variability of Child Rib Bone Hounsfield Units using in vivo Computed Tomography, IRCOBI.
20. C.A. Schneider, W.S. Rasband, K.W. Eliceir, 2012. NIH Image to ImageJ: 25 years of image analysis, Nat. Methods, 9: 671-675.10.1038/nmeth.2089 ↗
21. K. Shigeta, Y. Kitagawa, T. Yasuki, 2009. Development of next generation human finite element model capable of organ injury prediction, In: Proc. 21st ESV Conference. 09-0111.
22. Evaluation of thoracic deflection as an injury criterion for side impact using a finite elements thorax model
23. Staal · 2004
24. Subit D, Salzar R, 2014. Ribcage Kinematics Under Belt Loading in Intact, Denuded and Eviscerated Conditions, Japanese Society of Automotive Engineers, Spring Congress.
25. D. Subit, S. Boruah, J. Forman, R. Salzar, J. Crandall, 2013. Mechanical Response of Human ribs Under Antero-posterior Bending: Rib Level Variability and Strain Distribution, Japanese Society of Automotive Engineers Annual Congress, 5517, 2013.
26. Morphometric analysis of variation in the ribs with age and sex10.1111/joa.12203 ↗