journal article·2016-06

Fracture behavior of inlay and onlay fixed partial dentures – An in-vitro experimental and XFEM modeling study

Zhongpu Zhang, Mark Thompson, Clarice Field, Wei Li, Qing Li, Michael V. Swain

Publisher page

Abstract

Objectives This study aimed to explore the "sensitivity" of the fracture load and initiation site to loading position on the central occlusal surface of a pontic tooth for both all-ceramic inlay retained and onlay supported partial denture systems. Materials and methods Three dimensional (3D) finite element (FE) inlay retained and onlay supported partial denture models were established for simulating crack initiation and propagation by using the eXtended Finite Element Method (XFEM). The models were subjected to a mastication force up to 500N on the central fossa of the pontic. The loading position was varied to investigate its influence on fracture load and crack path. Results Small perturbation of the loading position caused the fracture load and crack pattern to vary considerably. For the inlay fixed partial dentures (FPDs), the fracture origins changed from the bucco-gingival aspect of the molar embrasure to the premolar embrasure when the indenter force location is slightly shifted from the mesial to distal side. In contrast, for onlay FPDs, cracking initiated from bucco-gingival aspect of the premolar embrasure when the indenter is slightly shifted to the buccal side and from molar embrasure when the indenter is shifted to the lingual side. Conclusions The fracture load and cracking path were found to be very sensitive to loading position in the all-ceramic inlay and onlay FPDs. The study provides a basis for improved understanding on the role of localized contact loading of the cusp surface in all-ceramic FPDs.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Health and Care Utilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Translucency of zirconia copings made with different CAD/CAM systems10.1016/S0022-3913(10)60086-8 ↗
2. Effect of property gradients on enamel fracture in human molar teeth10.1016/j.jmbbm.2012.06.014 ↗
3. Mechanics of longitudinal cracks in tooth enamel10.1016/j.actbio.2011.01.038 ↗
4. In vitro performance of full-contour zirconia single crowns10.1016/j.dental.2011.11.024 ↗
5. A simulation-based design paradigm for complex cast components10.1007/s00366-006-0030-1 ↗
6. A study of bite force, part 1: relationship to various physical characteristics
7. A study of maximum bite force during growth and development
8. A periodontal ligament driven remodeling algorithm for orthodontic tooth movement10.1016/j.jbiomech.2014.02.030 ↗
9. Crack propagation in continuous media: PMM vol. 31, no. 3, 1967, pp. 476–48810.1016/0021-8928(67)90034-2 ↗
10. State of the art of zirconia for dental applications10.1016/j.dental.2007.05.007 ↗
11. Mechanical responses to orthodontic loading: a 3-dimensional finite element multi-tooth model10.1016/j.ajodo.2007.03.032 ↗
12. A comparative mechanical and bone remodelling study of all-ceramic posterior inlay and onlay fixed partial dentures10.1016/j.jdent.2011.10.003 ↗
13. An Abaqus implementation of the extended finite element method10.1016/j.engfracmech.2008.10.015 ↗
14. A combined XFEM and cohesive zone model for composite laminate microcracking and permeability10.1016/j.compstruct.2014.09.068 ↗
15. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics10.1016/j.dental.2003.05.002 ↗
16. Modelling of fracture behaviour in biomaterials10.1016/j.biomaterials.2006.10.035 ↗
17. Restoration of non-carious cervical lesions – Part I. Modelling of restorative fracture10.1016/j.dental.2007.02.003 ↗
18. Restoration of non-carious cervical lesions – Part II. Restorative material selection to minimise fracture10.1016/j.dental.2007.02.002 ↗
19. Fracture resistance of teeth restored with different resin-based restorative systems10.1590/S1806-83242012005000004 ↗
20. In vitro fracture resistance of posterior metal-ceramic and all-ceramic inlay-retained resin-bonded fixed partial dentures10.1016/j.prosdent.2004.07.001 ↗
21. Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia10.1016/j.actbio.2008.04.012 ↗
22. Acrylic bone cements: composition and properties10.1016/j.ocl.2004.06.010 ↗
23. Numerical simulation of crack formation in all ceramic dental bridge10.4028/www.scientific.net/KEM.312.293 ↗
24. Fibre reinforced composite dental bridge. Part I: experimental investigation10.1016/j.biomaterials.2004.01.010 ↗
25. Fibre reinforced composite dental bridge. Part II: numerical investigation10.1016/j.biomaterials.2004.01.011 ↗
26. Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge10.1002/jbm.b.30233 ↗
27. Recent developments on damage modeling and finite element analysis for composite laminates: a review10.1016/j.matdes.2010.03.031 ↗
28. A stabilization technique for the regularization of nearly singular extended finite elements10.1007/s00466-014-1003-7 ↗
29. Strength and reliability of four-unit all-ceramic posterior bridges10.1016/j.dental.2004.11.012 ↗
30. Comparison of the criteria for mixed-mode brittle-fracture based on the preinstability stress-strain field. Part 1. slit and elliptical cracks under uniaxial tensile loading10.1007/BF00020696 ↗
31. Fracture strength of prefabricated all-ceramic posterior inlay-retained fixed dental prostheses10.1016/j.dental.2009.07.013 ↗
32. Energy-based modeling of cohesive and cohesionless cracks via X-FEM10.1016/j.cma.2006.11.016 ↗
33. Structure of periodontal tissues in health and disease10.1111/j.1600-0757.2005.00141.x ↗
34. Nanci · 2003
35. Influence of connector design on fracture probability of ceramic fixed-partial dentures10.1177/154405910208100909 ↗
36. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures10.1067/mpr.2002.123850 ↗
37. Two-year evaluation indicates zirconia bridges acceptable alternative to PFMs
38. Deformation analysis of the periodontium considering the viscoelasticity of the periodontal ligament10.1016/j.dental.2009.03.014 ↗
39. Design features of a three-dimensional molar crown and related maximum principal stress. A finite element model study10.1016/j.dental.2009.09.009 ↗
40. Effects of geometry on fracture initiation and propagation in all-ceramic crowns10.1002/jbm.b.31133 ↗
41. Influence of connector width on the stress distribution of posterior bridges under loading
42. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
43. Tooth eruption results from bone remodelling driven by bite forces sensed by soft tissue dental follicles: a finite element analysis
44. Relationships between the size, position, and angulation of human jaw muscles and unilateral first molar bite force10.1177/00220345890680031401 ↗
45. Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges10.1016/j.dental.2005.12.008 ↗
46. In vitro lifetime of dental ceramics under cyclic loading in water10.1016/j.biomaterials.2006.12.033 ↗
47. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing10.1016/j.dental.2004.07.013 ↗
48. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures10.1016/j.actbio.2008.12.016 ↗
49. Fractographic analyses of zirconia-based fixed partial dentures10.1016/j.dental.2007.12.006 ↗
50. The all-ceramic, inlay supported fixed partial denture. Part 3. Experimental approach for validating the finite element analysis10.1111/j.1834-7819.2011.01638.x ↗
51. The all-ceramic, inlay supported fixed partial denture. Part 4. Fracture surface analyses of an experimental model, all-ceramic, inlay supported fixed partial denture10.1111/adj.12040 ↗
52. The all-ceramic, inlay supported fixed partial denture. Part 5. Extended finite element analysis validation10.1111/adj.12107 ↗
53. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study
54. The variability of bite force measurement between sessions, in different positions within the dental arch10.1046/j.1365-2842.1998.00293.x ↗
55. All-ceramic restorations: classification and clinical evaluations
56. Maximum voluntary molar bite force in subjects with normal occlusion10.1093/ejo/cjq097 ↗
57. Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design10.1111/j.1600-0722.2009.00693.x ↗
58. Fracture strength of all-ceramic posterior inlay-retained fixed partial dentures10.1016/j.dental.2006.12.006 ↗
59. Characteristics of windshield cracking upon low-speed impact: numerical simulation based on the extended finite element method10.1016/j.commatsci.2010.02.026 ↗
60. From porcelain-fused-to-metal to zirconia: clinical and experimental considerations10.1016/j.dental.2010.10.024 ↗
61. Thermally induced fracture for core-veneered dental ceramic structures10.1016/j.actbio.2013.05.009 ↗
62. Mechanical benefits of conservative restoration for dental fissure caries10.1016/j.jmbbm.2015.08.010 ↗
63. Numerical simulation of the biomechanical behaviour of multi-rooted teeth10.1093/ejo/cji020 ↗