Effect of solvent/disinfectant ethanol on the micro-surface structure and properties of multiphase denture base polymers
Source abstract
Abstract
Aim of the study The aim of this study was to evaluate the effect of solvent/disinfectant ethanol on the surface of denture base polymers. Changes in surface roughness, topography and some nanomechanical properties were assessed by SEM and nanoindentation plotted against different concentrations of ethanol on heat cured and autopolymerized polymetyl methacrylate based acrylic denture base polymers. Materials and methods Test specimens (10×10×3mm(3)) of heat-curing (HC) and auto-polymerizing (AP) acrylic resin were prepared and polished to obtain uniform smoothness which were further grouped into 3 sub-groups HC1, HC2, HC3 and AP1, AP2, AP3 respectively 10 specimens (n) in each group. HC1 and AP1, HC2 and AP2, HC3 and AP3 were treated with 99.9%, 70% and 40% respectively for 30, 60 and 120s followed by analysis of surface roughness (Sa), topographical changes and some nanomechanical properties. Results Both HC and AP resins showed changes in their Sa and nanomechanically measured modulus of elasticity and surface hardness after being treated at different concentrations of ethanol and at different lengths of time. Surface changes were most clearly seen in autopolymerizing denture base polymer, especially at the interface region between the PMMA polymer bead and polymer matrix. There was a correlation (R2=0.83, r=0.91, P<0.001) between the time of treatment by ethanol and thickness of the affected area of denture base polymer. Conclusion The present study demonstrated that denture base polymers, especially autopolymerized denture base polymer is prone for surface crazing and dissolving by solvent/disinfectant ethanol. The interphase region between the PMMA polymer bead and the polymer matrix was most affected by the ethanol.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Surgical Sutures and Adhesives · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. The effect of disinfection procedures on flexural properties of denture base acrylics10.1016/0022-3913(92)90303-R ↗
2. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature10.1016/S0109-5641(97)80038-3 ↗
3. Brandrup · 1975 · 340
4. Brandrup · 1999 · Vol. 1
5. Alcohol water solvent systems for poly (methyl methacrylate10.1016/0032-3861(87)90360-0 ↗
6. Craig · 1993 · 514
7. Changes in hardness and surface topography of tissue conditioners submitted to chemical disinfection
8. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
9. Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins10.4012/dmj.28.307 ↗
10. Prediction of environmental stress cracking of polycarbonate from solubility consideration10.1002/app.1979.070230419 ↗
11. Homogeneous atom transfer radical polymerization of methyl methacrylate at ambient temperature in aqueous ethanol10.1021/ma0497613 ↗
12. Cyclic stress–strain behavior of the dry polycarbonate craze
13. Kambour, R.P., 1972. A review of crazing and fracture in thermoplastics. General Electric Report No. 72CRD285, October.
14. Influence of molecular weight of polymethyl(methacrylate) beads on the properties and structure of cross-linked denture base polymer10.1016/j.jmbbm.2011.06.001 ↗
15. High-performance liquid chromatographic estimation of eluates from denture base polymers10.1016/0300-5712(89)90137-1 ↗
16. Effect of toothbrushing, chemical disinfection and thermocycling procedures on the surface microroughness of denture base acrylic resins10.1111/j.1741-2358.2011.00582.x ↗
17. Effects of chemical disinfectants on the surface characteristics and color of denture resins10.1016/S0022-3913(97)70235-X ↗
18. Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials10.1590/S1678-77572011000500015 ↗
19. Influence of processing and molecular parameters on the dissolution rate of poly-(methyl mathacrylate) thin films10.1149/1.2100807 ↗
20. Crazing by disentanglement: non-diffusive reptation10.1016/0032-3861(89)90325-X ↗
21. Cytotoxicity of four types of resins used for removable denture bases: in vitro comparative analysis
22. Release of residual methyl methacrylate into water from glass fiber polymethyl methacrylate composite used in dentures10.1016/S0142-9612(96)00123-8 ↗
23. Ethanol postpolymerization treatment for improving the biocompatibility of acrylic reline resins
24. Microhardness of resin cements in the intraradicular environment: effects of water storage and softening treatment10.1016/j.dental.2009.01.096 ↗
25. Synergism in the swelling and solubility of poly (methyl methacrylate) in presence of ethanol/water mixtures10.1002/marc.1982.030030602 ↗
26. Effect of repaeted cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins10.1111/j.1741-2358.2009.00282.x ↗
27. Conversion in denture base polymers10.1002/jbm.820160520 ↗
28. Flexural properties of denture base polymers10.1016/0022-3913(80)90362-5 ↗
29. The effect of glutaraldehyde base disinfectants on denture base resins10.1016/0022-3913(89)90281-3 ↗
30. Effect of chemical disinfection on the surface roughness of denture base materials: a systematic review10.11607/ijp.3759 ↗
31. Stress crazing of some amorphous thermoplastics10.1002/app.1962.070062314 ↗
32. Effect of water sorption on the resistance to plastic deformation of a denture base material relined with four different denture reline materials
33. The evaluation of water sorption/solubility on various acrylic resins10.1055/s-0039-1697377 ↗
34. The solution process
35. Acrylic resin-fiber composite–part II: the effect of polymerization shrinkage of polymethyl methacrylate applied to fiber roving on the transverse strength10.1016/0022-3913(94)90447-2 ↗
36. Swelling of polymethyl(methacrylate) resin at the repair joint
37. Polymerization time and temperature affects the residual monomer content of denture base polymers10.1046/j.0909-8836.1998.eos106109.x ↗
38. Adherence of Candida albicans to the surface of polymethylmethacrylate E glass fiber composite used in dentures
39. The effect of glass fiber reinforcement on the residual monomer content of two denture base resins
40. Effect of resin hydrophilicity and water storage on resin strength10.1016/j.biomaterials.2004.01.026 ↗
41. A long term study on residual monomer release from denture materials