journal article·2014-12

Fiber heart valve prosthesis: Influence of the fabric construction parameters on the valve fatigue performances

Antoine Vaesken, Frederic Heim, Nabil Chakfe

Publisher page

Abstract

Transcatheter aortic valve replacement (TAVR) has become today a largely considered alternative technique to surgical valve replacement in patients who are not operable or patients with high risk for open chest surgery. However, the biological valve tissue used in the devices implanted clinically appears to be fragile material when folded for low diameter catheter insertion purpose and released in calcified environment with irregular geometry. Textile polyester material is characterized by outstanding folding and strength properties combined with proven biocompatibility. It could thereof be considered to replace biological valve leaflets in the TAVR procedure. The textile construction parameters must however be tuned to obtain a material compatible with the valve requested durability. In that context, one issue to be addressed is the friction effect that occurs between filaments and between yarns within a fabric under flexure loading. This phenomenon could be critical for the resistance of the material on the long term. The purpose of the present work is to assess the fatigue performances of textile valve prototypes made from different fabric constructions (monofilament, multifilament, calendered mutifilament) under accelerated cyclic loading. The goal is to identify, which construction is the best suited to long term fatigue stress. Results show that calendered multifilament and monofilament fabric constructions undergo strong ruptures already from 40 Mio cycles, while non calendered multifilament appears more durable. The rupture patterns observed point out that durability is directly related to the flexure stiffness level of the fibrous elements in the construction.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Cardiac Structural Anomalies and Repair · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Textile heart valve prosthesis: the effect of fabric construction parameters on long term durability10.1177/0040517507101457 ↗
2. Textile heart valve prosthesis: manufacturing process and prototype performances10.1177/0040517508092007 ↗
3. Textile heart valve: novel shaping process and material performances10.1080/10426914.2011.552018 ↗
4. Textile heart valve prosthesis: from fabric design criteria to early in-vivo performances
5. Current developments and future prospects for heart valve replacement therapy10.1002/jbm.b.31151 ↗
6. Crimping may affect the durability of transcatheter valves: an experimental analysis10.1016/j.athoracsur.2011.03.020 ↗
7. Millenium Research Group, European Markets for Heart Valve Devices 2011, Yearly Report, August 2011.
8. Deformation of the stentless porcine valve scaffold enhances accelerated leaflet fibrosis and calcification in juvenile sheep
9. Percutaneous aortic valve replacement will become a common treatment for aortic valve disease
10. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent10.1016/j.jacc.2007.10.023 ↗