journal article·2016-08

The mechanical and tribological properties of UHMWPE loaded ALN after mechanical activation for joint replacements

Kemeng Gong, Shuxin Qu, Yumei Liu, Jing Wang, Yongchao Zhang, Chongxi Jiang, Ru Shen

Publisher page

Abstract

Ultra-high molecular weight polyethylene (UHMWPE) loaded with alendronate sodium (ALN) has tremendous potential as an orthopeadic biomaterial for joint replacements. However, poor mechanical and tribological properties of UHMWPE-ALN are still obstacle for further application. The purpose of this study was to investigate the effect and mechanism of mechanical activation on mechanical and tribological properties of 1wt% ALN-loaded UHMWPE (UHMWPE-ALN-ma). In this study, tensile test, small punch test and reciprocating sliding wear test were applied to characterize the mechanical and tribological properties of UHMWPE-ALN-ma. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and Fourier transform infrared spectroscopy (FTIR) were employed to characterize UHMWPE-ALN-ma. Tensile test and small punch test showed that Young׳s modulus, tensile strength and work-to-failure (WTF) of UHMWPE-ALN-ma increased significantly compared to those of UHMWPE-ALN. The friction coefficients and wear factors of UHMWPE-ALN-ma both decreased significantly compared to those of UHMWPE-ALN. Mechanical activation obviously reduced type 1 (void) and type 2 (the disconnected and dislocated machining marks) fusion defects of UHMWPE-ALN-ma, which were revealed by SEM images of freeze fracture surfaces after etching and lateral surfaces of specimens after extension to fracture, respectively. It was attributed to peeled-off layers and chain scission of molecular chains of UHMWPE particles after mechanical activation, which were revealed by SEM images and FTIR spectra of UHMWPE-ALN-ma and UHMWPE-ALN, respectively. Moreover, EDS spectra revealed the more homogeneous distribution of ALN in UHMWPE-ALN-ma compared to that of UHMWPE-ALN. The present results showed that mechanical activation was a potential strategy to improve mechanical and tribological properties of UHMWPE-ALN-ma as an orthopeadic biomaterial for joint replacements.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Tribology and Wear Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. ASTM D638-03.Standard Test Method for Tensile Properties of Plastics.
2. ASTM F2102-06.Standard Guide for Evaluating the Extent of Oxidation in Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants.
3. ASTM F2183-02.Standard Test Method for Small Punch Testing of UHMWPE in Surgical Implants.
4. ASTM F732-00. Standard Test Method for Wear Testing of Polymeric Materials Used in Total Joint Prostheses.
5. Incorporation of amine moieties onto ultra-high molecular weight polyethylene (UHMWPE) surface via plasma and UV polymerization of allylamine10.1016/j.surfcoat.2015.01.027 ↗
6. Alendronate distributed on bone surfaces inhibits osteoclastic bone resorption in vitro and in experimental hypercalcemia models10.1016/8756-3282(94)00035-X ↗
7. A study of the wear resistance of three types of clinically applied UHMWPE for total replacement hip prostheses10.1016/S0142-9612(99)00096-4 ↗
8. Alendronate is a specific, nanomolar inhibitor of farnesyl diphosphate synthase10.1006/abbi.1999.1502 ↗
9. Mechanochemistry: the mechanical activation of covalent bonds10.1021/cr030697h ↗
10. Alendronate-hydroxyapatite nanocomposites and their interaction with osteoclasts and osteoblast-like cells10.1016/j.biomaterials.2007.10.040 ↗
11. Mechanochemistry of solids: past, present, and prospects10.1023/A:1011347706721 ↗
12. Vitamin E-stabilized UHMWPE for total joint implants10.1007/s11999-010-1717-6 ↗
13. UHMWPE for arthroplasty: past or future?10.1007/s10195-008-0038-y ↗
14. Low-voltage scanning electron microscopy of polymers10.1016/0032-3861(95)90924-Q ↗
15. Charnley total hip arthroplasty in patients less than fifty years old - a twenty to twenty-five-year follow-up note10.2106/00004623-199805000-00011 ↗
16. Bisphosphonate-related osteonecrosis of the jaws-an initial case series report of treatment combining partial bone resection and autologous platelet-rich plasma10.1016/j.joms.2011.02.078 ↗
17. Ultra high molecular weight polyethylene with improved plasticity and toughness by high temperature melting10.1016/j.polymer.2010.04.003 ↗
18. Comparison of wear of ultra high molecular weight polyethylene acetabular cups against alumina ceramic and chromium nitride coated femoral heads10.1016/j.wear.2005.02.016 ↗
19. Enhanced gap filling and osteoconduction associated with alendronate-calcium phosphate-coated porous tantalum10.2106/JBJS.G.00415 ↗
20. Mechanical properties and biocompatibility of melt processed, self-reinforced ultrahigh molecular weight polyethylene10.1016/j.biomaterials.2014.04.077 ↗
21. Chemical burn of the tongue resulting from improper use of oral bisphosphonate10.1016/j.ajoms.2011.06.001 ↗
22. Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial10.1016/j.arth.2009.05.020 ↗
23. (v) Biotribology10.1016/j.cuor.2005.09.005 ↗
24. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty10.1016/S0142-9612(99)00053-8 ↗
25. Properties of crosslinked ultra-high-molecular-weight polyethylene10.1016/S0142-9612(00)00195-2 ↗
26. UHMWPE carrying estradiol to treat the particle-induced osteolysis - processing and characterizing10.1002/jbm.a.32120 ↗
27. Time-of-flight secondary ion mass spectrometry study on the distribution of alendronate sodium in drug-loaded ultra-high molecular weight polyethylene10.1088/1748-6041/4/6/065008 ↗
28. The influence of zoledronic acid and cyclophosphamide on microcirculation regeneration in healing oral mucosal flaps10.1016/j.archoralbio.2010.11.015 ↗
29. Poly (L-lactide-co-Є caprolactone) microspheres laden with bioactive glass-ceramic and alendronate sodium as bone regenerative scaffolds10.1016/j.msec.2012.01.011 ↗
30. Retrieved total hip prostheses - part I-the effects of cup thickness, head sizes and fusion defects on wear10.1023/A:1013283513509 ↗
31. Improved wear resistance of orthopaedic UHMWPE by reinforcement with zirconium particles10.1016/j.wear.2008.11.028 ↗
32. Study on in vitro release and cell response to alendronate sodium-loaded ultrahigh molecular weight polyethylene loaded with alendronate sodium wear particles to treat the particles-induced osteolysis10.1002/jbm.a.34327 ↗
33. Microstructure and properties of composite materials based on UHMWPE after mechanical activation10.1016/j.jallcom.2013.12.175 ↗
34. UHMWPE-based nanocomposite as a material for damaged cartilage replacement10.1016/j.msec.2014.12.050 ↗
35. Inhibition of wear debris mediated osteolysis in a canine total hip arthroplasty model10.1097/00003086-199711000-00005 ↗
36. Microstructure and properties of alendronate-loaded calcium phosphate cement10.1016/j.msec.2014.05.043 ↗
37. Characterization of physical, chemical, and mechanical properties of UHMWPE
38. Mechanical integrity of compression-moulded ultra-high molecular weight polyethylene: effects of varying process conditions10.1016/S0142-9612(02)00117-5 ↗
39. Wear performance of ultrahigh molecular weight polyethylene/quartz composites10.1016/S0142-9612(02)00610-5 ↗
40. Characterization of alendronate sodium-loaded UHMWPE for anti-osteolysis in orthopedic applications10.1016/j.msec.2011.09.012 ↗
41. Preliminary study on the effect of wear process on drug release of ALN-loaded UHMWPE10.1016/j.apsusc.2012.05.012 ↗
42. Biotribology: recent progresses and future perspectives10.1016/j.bsbt.2015.03.001 ↗
43. The effects of local and systemic alendronate delivery on wear debris-induced osteolysis in vivo10.1002/jor.21062 ↗