journal article·2019-03

Influence of contact configuration and lubricating conditions on the microtriboactivity of the zirconia-Ti6Al4V pair used in dental applications

A.C. Branco, V. Moreira, J.A. Reis, R. Colaço, C.G. Figueiredo-Pina, A.P. Serro

Publisher page

Abstract

Loosening and fracture of implanted dental crowns is a consequence of relative micromovements between the zirconia abutment and the titanium alloy of the implant, in a biochemical aggressive environment. Thus, it is important to establish the in vitro tribological testing conditions that better mimics such environment. The present work aims to evaluate the effect of ball-on-plate tests configuration on the tribological behavior of ZrO2/Ti6Al4V pair in dry and lubricated conditions, using different lubricants: water, artificial saliva solution and human saliva. Ceramic balls sliding on metallic plates (TiPlate) and metallic balls sliding on ceramic plates (TiBall) were tested and the coefficient of friction (CoF) and wear response was monitored trough nanotribological tests. Open circuit potential was also measured during the tests carried out in saline solution (artificial saliva) to access the tribochemical response. The wear mechanisms were evaluated by scanning electron microscopy and atomic force microscopy analysis. Relevant differences were found between the two configurations, with and without the presence of human saliva: TiPlate presented always a higher CoF than TiBall, which may have resulted from differences in the degradation and regeneration processes of the titanium passive film during sliding. TiBall demonstrated to be the best choice to reproduce the in vivo conditions, since the metallic surface contacts permanently with zirconia, impairing the titanium repassivation. Regarding the effect of the lubricants, it was observed that human saliva had a protective action of the surfaces, leading to the lowest CoF among the lubricants used (0.19 ± 0.05 for TiBall and 0.35 ± 0.08 for TiPlate) and neglectable wear.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Fracture resistance of yttria-stabilized zirconia dental implant abutments10.1111/j.1532-849X.2008.00378.x ↗
2. Influence of artificial saliva compositions on tribological characteristics of Ti-6Al-4V implant alloy
3. Zirconia in dental implantology: a review10.4103/2231-0762.158014 ↗
4. Ar, J., Marco, M., Pj, M., Diogo, M., M, F.V., Luís, R., Bn, I., 2017. Wear of the Implant Connection with Zirconia and Titanium Abutments, pp. 1–9.
5. Influence of the machining cooling strategies on the dental tribocorrosion behaviour of wrought and additive manufactured Ti6Al4V10.1016/j.biotri.2017.03.002 ↗
6. Black · 1998
7. The lubricating properties of human whole saliva10.1007/s11249-007-9232-y ↗
8. Biofilm and saliva affect the biomechanical behavior of dental implants10.1016/j.jbiomech.2015.02.004 ↗
9. Boyer · 1994
10. Examination of the implant – abutment interface after fatigue testing10.1067/mpr.2001.114266 ↗
11. Viscoelastic properties and dynamics of porcine gastric mucin10.1021/bm0493990 ↗
12. Mechanical properties and failure of Streptococcus mutans biofilms, studied using a microindentation device10.1016/j.mimet.2006.04.023 ↗
13. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
14. Clinical complications of osseointegrated implants10.1016/S0022-3913(99)70208-8 ↗
15. Green · 1998
16. Friction and wear of A1203, Zr02 and Si02 rubbed against pure metals10.1016/0043-1648(92)90176-9 ↗
17. Hutchings · 1992
18. Wear behavior of tetragonal zirconia polycrystal versus titanium and titanium alloy10.1088/1748-6041/6/2/021001 ↗
19. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
20. A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments
21. Environmental degradation of zirconia ceramics10.1016/0955-2219(95)00035-S ↗
22. Tribological characteristic of titanium alloy surface layers produced by diode laser gas nitriding10.1515/amm-2016-0094 ↗
23. Loginov, Y.N., Golodnov, A.I., Stepanov, S.I., Kovalev, E.Y., 2017. Determining the young’s modulus of a cellular titanium implant by FEM simulation.10.1063/1.5017330 ↗
24. Candido, Lucas Miguel, Fais, Laiza Maria Grassi, Reis, José Mauricio dos Santos Nunes, P., L.A.P., 2014. Surface roughness and hardness of yttria stabilized zirconia (Y-TZP) after 10 years of simulated brushing 43, pp. 379–383.10.1590/1807-2577.1049 ↗
25. Low temperature degradation -aging- of zirconia: a critical review of the relevant aspects in dentistry10.1016/j.dental.2010.04.006 ↗
26. Zirconia implant abutment fracture: clinical case reports and precautions for use
27. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
28. Pre-fabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: success and failure after 3 years of function10.3109/00016357.2013.863970 ↗
29. A critical review of dental implant materials with an emphasis on titanium versus zirconia10.3390/ma8030932 ↗
30. Tribocorrosion behaviour of Ti6Al4V in artificial seawater at low contact pressures10.1016/j.triboint.2017.10.025 ↗
31. The human masticatory system from a biomechanical perspective: a review
32. Product Design Guide for Forging, 1997. Forging Industry Association.
33. Ratner · 2004
34. Effect of bleaching teeth with hydrogen peroxide on the morphology, hydrophilicity, mechanical and tribological properties of the enamel10.1016/j.wear.2016.11.001 ↗
35. A 16-year study of the microgap between 272 human titanium implants and their abutments10.1563/753.1 ↗
36. Adsorption of albumin on prosthetic materials: implication for tribological behaviour10.1002/jbm.a.30754 ↗
37. A comparison between screw and cement-retained implant prostheses. a literature review10.1563/AAID-JOI-D-10-00146 ↗
38. Dental implants: materials and design considerations
39. Wear and corrosion interactions on titanium in oral environment: literature review10.1007/s40735-015-0013-0 ↗
40. Biofilms inducing ultra-low friction on titanium10.1177/0022034510378428 ↗
41. An esthetic comparison of a metal ceramic crown and cast metal abutment with an all-ceramic crown and zirconia abutment: a clinical report10.1016/j.prosdent.2003.12.024 ↗
42. Titanium tattooing associated with zirconia implant abutments: a clinical report of two cases10.11607/jomi.3700 ↗
43. Foreign bodies associated with peri-implantitis human biopsies10.1902/jop.2014.140363 ↗
44. Implant screw mechanics and the settling effect: an overview10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2 ↗