Abstract

Computational modelling is becoming ever more important for obtaining regulatory approval for new medical devices. An accepted approach is to infer performance in a population from an analysis conducted for an idealised or 'average' patient; we present here a method for predicting the performance of an orthopaedic implant when released into a population--effectively simulating a clinical trial. Specifically we hypothesise that an analysis based on a method for predicting the performance in a population will lead to different conclusions than an analysis based on an idealised or 'average' patient. To test this hypothesis we use a finite element model of an intramedullary implant in a bone whose size and remodelling activity is different for each individual in the population. We compare the performance of a low Young's modulus implant (E=20 GPa) to one with a higher Young's modulus (200 GPa). Cyclic loading is applied and failure is assumed when the migration of the implant relative to the bone exceeds a threshold magnitude. The analysis for an idealised of 'average' patient predicts that the lower modulus device survives longer whereas the analysis simulating a clinical trial predicts no statistically-significant tendency (p=0.77) for the low modulus device to perform better. It is concluded that population-based simulations of implant performance-simulating a clinical trial-present a very valuable opportunity for more realistic computational pre-clinical testing of medical devices.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Hip contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
2. The compressive behavior of bone as a two-phase porous structure
3. Fatigue life of compact bone II—effects of microstructure and density10.1016/0021-9290(76)90006-3 ↗
4. Probabilistic analysis of an uncemented total hip replacement10.1016/j.medengphy.2009.01.002 ↗
5. Reconstruction of the formative site in iliac trabecular bone in 20 normal individuals employing a kinetic model for matrix and mineral apposition10.1016/0221-8747(84)90066-3 ↗
6. Reconstruction of the resorptive site in iliac trabecular bone: A kinetic model for bone resorption in 20 normal individuals10.1016/0221-8747(84)90065-1 ↗
7. Size and shape of the resection surface geometry of the osteoarthritic knee in relation to total knee replacement design10.1243/09544119JEIM332 ↗
8. In vivo measurements of bone deformations using strain gauges
9. A determinant of bone architecture. The minimum effective strain10.1097/00003086-198305000-00047 ↗
10. Bone mass and the “mechanostat”: A proposal10.1002/ar.1092190104 ↗
11. Skeletal structural adaptations to mechanical usage (SATMU): 1. Redefining Wolff’s law: The bone modeling problem10.1002/ar.1092260402 ↗
12. Bone’s mechanostat: a 2003 update10.1002/ar.a.10119 ↗
13. Mathematical relationships between bone density and mechanical properties: a literature review10.1016/j.clinbiomech.2007.08.024 ↗
14. Musculo-skeletal loading conditions at the hip during walking and stair climbing10.1016/S0021-9290(01)00039-2 ↗
15. Determination of muscle loading at the hip joint for use in pre-clinical testing10.1016/j.jbiomech.2004.05.022 ↗
16. A survey of finite element analysis in orthopedic biomechanics: the first decade10.1016/0021-9290(83)90072-6 ↗
17. Adaptive bone-remodeling theory applied to prosthetic-design analysis10.1016/0021-9290(87)90030-3 ↗
18. Swedish hip arthroplasty register: Annual report 2007
19. Biomaterials in total joint replacement10.1016/j.colsurfb.2003.12.002 ↗
20. Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechanosensitivity10.1016/j.jbiomech.2011.02.003 ↗
21. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading10.1016/j.jbiomech.2006.07.027 ↗
22. Probabilistic finite element prediction of knee wear simulator mechanics10.1016/j.jbiomech.2005.07.029 ↗
23. Bone adaptation to load: Microdamage as a stimulus for bone remodelling10.1046/j.1469-7580.2002.00123.x ↗
24. Predicting revision risk for aseptic loosening of femoral components in total hip arthroplasty in individual patients—a finite element study10.1002/jor.20346 ↗
25. Prognosis of total hip replacement in Sweden: Follow-up of 92,675 operations performed 1978–199010.3109/17453679308993679 ↗
26. Bone remodelling algorithms incorporating both strain and microdamage stimuli10.1016/j.jbiomech.2006.05.007 ↗
27. Duration and frequency of every day activities in total hip patients10.1016/S0021-9290(01)00035-5 ↗
28. An algorithm for bone mechanoresponsiveness: Implementation to study the effect of patient-specific cell mechanosensitivity on trabecular bone loss10.1080/10255840802136150 ↗
29. Mechanobiological regulation of the remodelling cycle in trabecular bone and possiblebiomechanical pathways for osteoporosis10.1016/j.clinbiomech.2010.01.006 ↗
30. The anatomic basis of femoral component design10.1097/00003086-198810000-00015 ↗
31. Long-term remodeling in proximal femur around a hydroxyapatite-coated anatomic stem: Ten years densitometric follow-up10.1016/j.arth.2007.12.017 ↗
32. Finite element models in tissue mechanics and orthopaedic implant design10.1016/S0268-0033(97)00018-1 ↗
33. Bone Prostheses and implants
34. Prendergast, P.J., 2007. Combining mechanoregulation algorithms for bone remodelling and tissue differentiation. In: Y. González & M. Cerrolaza (Eds.), Bioengineering Modelling and Computer Simulation International Center for Numerical Methods in Engineering, Barcelona, pp. 238–248.
35. Design of intramedullary prostheses to prevent bone loss: Predictions based on damage-stimulated remodelling10.1016/0141-5425(92)90103-R ↗
36. Cortical and interfacial bone changes around a non-cemented hip implant: simulations using a combined strain/damage remodelling algorithm10.1016/j.medengphy.2008.11.007 ↗
37. Finite element-based preclinical testing of cemented total hip implants10.1097/BLO.0b013e31802ba491 ↗
38. Explicit finite element simulation of eccentric loading in total knee replacement10.1097/01.blo.0000079267.91782.58 ↗
39. The effects of cement-stem debonding in THA on the long-term failure probability of cement10.1016/S0021-9290(97)00038-9 ↗
40. Primary stability of an anatomical cementless hip stem: A statistical analysis10.1016/j.jbiomech.2005.03.024 ↗
41. Effects of material properties of femoral hip components on bone remodeling10.1002/jor.1100100614 ↗