This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents derived from braiding method were covered with membrane prepared via electrospinning method, and nine FCBPBSs were then obtained for bending test to evaluate the bending flexibility. In addition, by the finite element method, nine numerical models based on actual biliary stent were established and the bending load was calculated through the finite element method. Results demonstrate that the simulation and experimental results are in good agreement with each other, indicating that the simulation results can be provided a useful reference to the investigation of biliary stents. Furthermore, the stress distribution on FCBPBSs was studied, and the plastic dissipation analysis and plastic strain of FCBPBSs were obtained via the bending simulation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Gallbladder and Bile Duct Disorders · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Biliary stents in malignant obstructive jaundice due to pancreatic carcinoma: a costeffectiveness analysis10.1111/j.1572-0241.2002.05606.x ↗
2. The biocompatibility Between electrospinning scaffold of PCL and PDLSCs (in chinese)
3. Expandable biliary endoprosthesis: an experimental study10.2214/ajr.145.6.1279 ↗
4. Small diameter electrospun silk fibroin vascular grafts: mechanical properties, in vitro biodegradability, and in vivo biocompatibility10.1016/j.msec.2015.05.003 ↗
5. Gastrointestinal and biliary stents10.1111/j.1440-1746.2009.06152.x ↗
6. Risk of post-ERCP pancreatitis with placement of self-expandable metallic stents10.1016/j.gie.2010.05.023 ↗
7. Randomized trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction10.1016/0140-6736(92)92752-2 ↗
8. Randomized clinical study of polydioxanone and nylon sutures for laparotomy closure in high-risk patients
9. In vitro degradation effects on strength, stiffness, and creep of PLLA/PBS: a potential stent material10.1080/00914037.2014.945203 ↗
10. In vivo evaluation of a new bioabsorbable self-expanding biliary stent10.1016/S0016-5107(03)02016-9 ↗
11. The current state of efficacy-cost of metal and plastic stent for bile duct obstruction treatment
12. A prospective multi-center study of a bioabsorbable biliary Wallstent in 50 patients with malignant obstructive jaundice
13. Plastic or metal stents for malignant stricture of the common bile duct? Results of a randomized prospective study10.1067/mge.2003.66 ↗
14. Compliance properties of collagen—coated polyethylene terephthalate vascular prostheses
15. A prospective randomized controlled trial of metal stents for malignant obstruction of the common bile duct10.1055/s-2007-1010294 ↗
16. Common bile duct obstruction due to malignancy: treatment with plastic versus metal stents10.1148/radiology.201.1.8816539 ↗
17. Obstructive jaundice: use of expandable metal endoprosthesis for biliary drainage
18. Characterization of compression behaviors of fully covered biodegradable polydioxanone biliary stent for human body: a numerical approach by finite element model10.1016/j.jmbbm.2016.04.029 ↗
19. Comparative performance of uncoated, self-expanding metal biliary stents of different designs in 2 diameters: final results of an international multicenter, randomized, controlled trial10.1016/j.gie.2008.11.018 ↗
20. Relation between tensile tests and compliance in polyester textile vascular prostheses10.1016/j.avsg.2015.02.014 ↗
21. Biodegradable biliary stent implantation in the treatment of benign bilioplastic-refractory biliary strictures: preliminary experience10.1007/s00330-013-2947-2 ↗
22. Electrospun vascular grafts with improved compliance matching to native vessels10.1002/jbm.b.33201 ↗
23. Polydioxanone-based bio-materials for tissue engineering and drug/gene delivery applications
24. Status evaluation report
25. Plastic versus self-expanding metallic stents for malignant hilar biliary obstruction: a prospective multicenter observational cohort study10.1097/MCG.0b013e31815853e0 ↗
26. Radial force analysis of polydioxanone coronary stent by finite element method
27. Palliative bile duct drainage-a new endoscopic method of introducing a transpapillary drain10.1055/s-2007-1021702 ↗
28. A prospective randomized multicenter trial comparing Doublelayer and polyethylene stents for malignant distal common bile duct strictures10.1055/s-2003-44601 ↗
29. Clinical outcomes of nitinol and stainless steel uncovered metal stents for malignant biliary strictures: is there a difference10.1016/j.gie.2010.08.035 ↗
30. Fatigue behaviors of four-step three dimensional braided composite material: a meso-scale approach computation10.1177/0040517514540767 ↗
31. A comparison of the Niti-D biliary uncovered stent and the uncovered Wallstent in malignant biliary obstruction10.1016/j.gie.2008.10.029 ↗
32. Comparative costs of metal versus plastic biliary stent strategies for malignant obstructive jaundice by decision analysis10.1016/S0016-5107(99)70044-1 ↗
33. Zhai W.Q., Zhen H.Y., Xing H.C. et al. 2011. The in vitro degradation study of two degradable intravascular stents materials. In: Proceedings of 2011 International Forum Biomedical Textile Materials. Shanghai, China, pp. 466-469.
34. Zhuang · 2004