Corrosion and metal release from overlapping arterial stents under mechanical and electrochemical stress – An experimental study
Source abstract
Abstract
Intra-arterial stenosis due to atherosclerosis is often treated with endovascular balloon dilatation with a metal stent. Restenosis is common and is frequently treated with a new stent placed inside the existing one or the stents are placed with overlap to cover a larger area of the vessels. Observations of stent fractures, stent compression, accumulation of immunocompetent cells around stents have suggested the possibility of immunologic reactions to substances released from stents. An accelerated corrosion model was developed to study corrosion behaviour of commonly used surgical peripheral stents. Single nitinol stents (n = 6), connected stents of the same material (stent-in-stent, both nitinol, n = 7) and connected stents of dissimilar alloys (Nitinol with stainless steel stent inside, n = 7) were investigated. The stents were subjected to mechanical pulsatile radial strain (up to 8% strain at 1 Hz) and electrochemical stress (+112 mV vs. SCE). The release of nickel and titanium ions was compared. Scanning electron images were obtained. There was a higher release of nickel when combining two similar (range: 1382-8018 μg/L, p = 0.0012) and dissimilar (range: 170-2497 μg/L, p = 0.0023) stents compared to single stents (range: 0.4-216 μg/L). The concentration of titanium was low (range: 1.6-98.4 μg/L) with only a difference between the single and two similar stents (p = 0.0047). Deposits of corrosion products were clearly visible after fretting and pitting corrosion mainly on the Nitinol stents. Several mesh wires were fractured. The study demonstrated that mechanical strain combined with weak electric potential resulted in pronounced corrosion and fracture of stents, especially with overlapping stents. Single stents after pulsatile load released the lowest amount of ions. The combination of stents of the same material (Nitinol) had the highest release of metal ions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Coronary Interventions and Diagnostics · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Inflammation, wound healing, and the foreign-body response
2. ASTM · 2008 · 9
3. Cutaneous and systemic hypersensitivity reactions to metallic implants10.2310/6620.2011.10055 ↗
4. Stent implantation in patients with metal allergy: a systemic review and meta-analysis10.1097/MCA.0b013e3283647ad1 ↗
5. Electrochemical control of cell death by reduction-induced intrinsic apoptosis and oxidation-induced necrosis on CoCrMo alloy in vitro10.1016/j.biomaterials.2012.05.054 ↗
6. Evaluation of metal allergies in patients with coronary stents10.1034/j.1600-0536.2002.470607.x ↗
7. Should the galvanic combination of titanium and stainless steel surgical implants be avoided?10.1016/j.injury.2007.07.015 ↗
8. International Organization for Standardization · 2004 · 10
9. Electrical potentials between stent-grafts made from different metals induce negligible corrosion10.1016/j.ejvs.2013.06.010 ↗
10. Occlusion of metallic biliary stent related to nickel allergy10.1016/j.gie.2006.11.004 ↗
11. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis10.1016/S0140-6736(00)03262-1 ↗
12. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the research on adverse drug events and reports (RADAR) project10.1016/j.jacc.2005.07.071 ↗
13. Eosinophil cationic protein and clinical outcome after bare metal stent implantation10.1016/j.atherosclerosis.2010.11.044 ↗
14. Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions10.1016/j.jvs.2008.02.029 ↗
15. Assessment of self-expanding nitinol stent deformation after chronic implantation into the femoropopliteal arteries10.4244/EIJV9I6A117 ↗
16. Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses10.5152/dir.2015.15062 ↗
17. Stent fractures after superficial femoral artery stenting10.4174/jkss.2012.83.3.183 ↗
18. Fatigue and durability of Nitinol stents10.1016/j.jmbbm.2007.08.001 ↗
19. The incidence of arterial stent fractures with exclusion of coronary, aortic, and non-arterial settings10.1016/j.ejvs.2008.05.005 ↗
20. Outcomes after coronary stent implantation in patients with metal allergy10.1161/CIRCINTERVENTIONS.111.966614 ↗
21. Metal allergic reaction in chronic refractory in-stent restenosis10.1016/j.carrev.2008.01.004 ↗
22. Prevalence and clinical impact of stent fractures after femoropopliteal stenting10.1016/j.jacc.2004.11.026 ↗
23. Inflammatory response to stent implantation: differences in femoropopliteal, iliac, and carotid arteries10.1148/radiol.2241011253 ↗
24. Effect of wire fretting on the corrosion resistance of common medical alloys10.1002/jbm.b.33788 ↗
25. Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis10.1016/S0140-6736(07)61444-5 ↗
26. Effects of oxide layer composition and radial compression on nickel release in nitinol stents10.1007/s40830-015-0028-x ↗
27. The effects of surface processing on in-vivo corrosion of Nitinol stents in a porcine model10.1016/j.actbio.2017.08.029 ↗
28. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study10.1111/j.1600-0536.2010.01857.x ↗
29. Trépanier · 2006
30. Reduced nickel sensitivity in young Danish women following regulation of nickel exposure10.1034/j.1600-0536.2001.045002104.x ↗
31. Association of localized hypersensitivity and in-stent neoatherosclerosis with the very late drug-eluting stent thrombosis10.1371/journal.pone.0113870 ↗
32. Percutaneous transluminal angioplasty with or without stenting for femoropopliteal occlusions? A randomized controlled study