journal article·2022-01Open access

Development and validation of a parametric human mandible model to determine internal stresses for the future design optimization of maxillofacial implants

Franziska Wieja, Georg Jacobs, Sebastian Stein, Alexander Kopp, Kerstin van Gaalen, Nadja Kröger, Max Zinser

Abstract

Large segmental mandible bone defects still represent a challenge for endogenous regeneration. Despite the bone's capacity to heal in many clinical situations, bone defects over a critical size do not heal spontaneously. An emerging treatment of critically sized mandibular defects is the implantation of individually manufactured scaffolds consisting of biodegradable magnesium alloys. Biomedical engineers faced the challenge of developing a scaffold structure that not only provides sufficient stability, but also stimulates and promotes bone growth while considering the degradation of the magnesium alloy. The porosity of the scaffold must also support bone ingrowth and neovascularization. For an optimal design and subsequent structural optimization knowledge of external load cases is essential. However, currently the muscle and joint forces of the mandible cannot be measured directly. The aim of our study was therefore the development of a parametric human mandible model to determine the relevant boundary conditions for the subsequent structural optimization of individual jawbone implants. Using a model-based approach, determining the essential external load of the mandible as a function of the age and sex of a patient individually and the realistic simulation of the mechanical stress for patient-specific loads and anatomies has been realized. The developed model is successfully validated by evaluating the deformations and stresses of the lower jaw of a possible patient and comparing them with the results of dental research. Based on the results of the modelling, in a subsequent optimization process section forces at the interface between the bone tissue and jawbone implant can be determined and used to optimize the design of the jawbone implant.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. The elastic properties of a human mandible10.1177/08959374870010011401 ↗
2. Mandibular fractures
3. Bite force and occlusion10.1053/j.sodo.2006.01.005 ↗
4. Clinical significance of isometric bite force versus electrical activity in temporal and masseter muscles
5. Unilateral, isometric bite force in 8-68-year-old women and men related to occlusal factors
6. A model relating patterns of human jaw movement to biomechanical constraints10.1016/0021-9290(84)90106-4 ↗
7. Critical sized mandibular defect regeneration in preclinical in vivo models10.1007/s40610-016-0036-4 ↗
8. Finite element analysis of the human mandible at 3 different stages of life, Oral Surgery10.1016/j.tripleo.2010.01.025 ↗
9. Bumann · 2016
10. FEM investigation of the stress distribution over mandibular bone due to screwed overdenture positioned on dental implants10.3390/ma11091512 ↗
11. Flexural and torsional properties of a glass fiber-reinforced composite diaphyseal bone model with multidirectional fiber orientation10.1016/j.jmbbm.2018.07.027 ↗
12. Elastic properties of human supraorbital and mandibular bone10.1002/ajpa.1330900304 ↗
13. Single tooth bite forces in healthy young adults10.1046/j.0305-182X.2003.01179.x ↗
14. Futterling · 1998 · 103
15. Resorbierbare implantate in der Unfallchirurgie10.1007/s41970-018-0041-6 ↗
16. Gütte · 2010
17. Modeling the biomechanics of the mandible: a three-dimensional finite element study10.1016/0021-9290(92)90025-V ↗
18. Heinemann · Resorbierbare Knochenersatzmaterialien, Der Orthopäde · 2011 · 40 · 76110.1007/s00132-011-1748-z ↗
19. Bite force and the state of dentition10.3109/00016357709064128 ↗
20. Mathematically indeterminate systems
21. Die vaskularisierte knochentransplantation10.1007/s00113-009-1613-2 ↗
22. The critical size defect as an experimental model to test bone repair materials10.1097/00001665-199001000-00011 ↗
23. Neue Materialien für eine bessere Patientenversorgung10.1007/s10039-013-2042-6 ↗
24. Stress and strain in the mandibular symphysis of primates: a test of competing hypothesis10.1002/ajpa.1330640102 ↗
25. Electromyography of the two heads of external pterygoid muscle via the intra-oral route
26. Kenhub GmbH · 2019
27. Klein · 2015
28. Koch-Institut · 2016
29. A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces10.1016/0021-9290(88)90219-9 ↗
30. Influence of design and postprocessing parameters on the degradation behavior and mechanical properties of additively manufactured magnesium scaffolds10.1016/j.actbio.2019.04.012 ↗
31. Three-dimensional finite element stress analysis of the dentate human mandible10.1002/ajpa.1330880107 ↗
32. Fatigue of mineralized tissues: cortical bone and dentin10.1016/j.jmbbm.2007.04.002 ↗
33. Funktioneller Bau und funktionelle Anpassung des Knochens
34. Analyse der funktionellen Struktur des menschlichen Unterkiefers
35. Additively manufactured biodegradable porous magnesium10.1016/j.actbio.2017.12.008 ↗
36. Biomechanical analysis comparing natural and alloplastic temporomandibular joint replacement using a finite element model10.1016/j.joms.2010.02.019 ↗
37. Experimentelle und Finite-Elemente-Analyse der Biomechanik des Unterkiefers unter Belastung10.1007/s100060050005 ↗
38. Nelson · 1986
39. Multi-layer porous fiber-reinforced composites for implants: in vitro calcium phosphate formation in the presence of bioactive glass10.1016/j.dental.2012.08.005 ↗
40. Niedhart · 2010 · 78—84
41. Investigations into age-related changes in the human mandible10.1111/1556-4029.13475 ↗
42. Pauwels · 1965
43. Mechanobiologically optimized 3D titanium-mesh scaffolds enhance bone regeneration in critical segmental defects in sheep10.1126/scitranslmed.aam8828 ↗
44. Rahimi · 2012
45. Shaping scaffold structures in rapid manufacturing implants: a modeling approach toward mechano-biologically optimized configurations for large bone defect10.1002/jbm.b.32740 ↗
46. The challenge of establishing preclinical models for segmental bone defect research10.1016/j.biomaterials.2008.12.050 ↗
47. Numerical estimation of bone density and elastic constants distribution in a human mandible10.1016/j.jbiomech.2006.03.007 ↗
48. Richard · 2013
49. The effects of dental condition on hand strength and maximum bite force10.1080/08869634.1993.11677940 ↗
50. The anterior component of occlusal force. Part 1. Measurement and distribution10.1016/0889-5406(89)90116-9 ↗
51. Establishing a critical-size mandibular defect model in growing pigs: characterization of spontaneous healing10.1016/j.joms.2014.02.024 ↗
52. Mandible fractures
53. Rekonstruktion segmentaler knochendefekte10.1007/s10039-012-1884-7 ↗
54. The variability of bite force measurement between sessions, in different positions within the dental arch10.1046/j.1365-2842.1998.00293.x ↗
55. Vallabh · 2019
56. Bite force and electromyograpy during maximum unilateral and bilateral clenching10.1111/j.1600-0722.2008.00531.x ↗
57. A mathematical model of the patellofemoral joint10.1016/0021-9290(86)90154-5 ↗
58. A feedback method to determine the three-dimensional bite-force capabilities of the human masticatory system10.1177/00220345880670020301 ↗
59. Architecture of the human jaw-closing and jaw-opening muscles10.1002/(SICI)1097-0185(199707)248:3<464::AID-AR20>3.0.CO;2-M ↗
60. Bite force recording devices - a review