journal article·2021-04

Taper junctions in modular hip joint replacements: What affects their stability?

Ulrike Mueller, Therese Bormann, Stefan Schroeder, J. Philippe Kretzer

Publisher page

Abstract

Background Although taper junctions are beneficial in the reconstruction of hip joints, some clinical concerns like the formation of adverse local tissue reactions have recently emerged. These reactions are associated with wear and corrosion products from the interface of insufficient taper connections regarding strength. Commonly used tapers vary in their geometric and topographical design parameter. Therefore, this study aims to evaluate interactions between design and surgical related parameters to the taper connection strength. Methods In this study, the effect of the taper contact situation, surface roughness and head material in combination with assembly force on the taper connection strength were assessed using torque-off tests. Furthermore, the type of use in terms of single-use or re-use of the stem taper was investigated. Results The study showed that the impaction force is the predominant factor that determines the taper strength followed by the type of use and the head material. The contact situation seems to slightly influence the determined torque-off moment, whereas the surface topography of the stem taper obviously plays a minor role for the taper connection strength. Conclusion Clinical users should be aware that an increased assembly force will strengthen the stability of the taper junction, whereas care should be taken when reusing hip stems with metal heads as this may decrease their connection strength.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. The role of surface shear strains in the adhesion of metals10.1016/0043-1648(60)90291-X ↗
2. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
3. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers10.1016/j.jbiomech.2020.109689 ↗
4. Dissociation of modular humeral head components: a biomechanical and implant retrieval study10.1016/S1058-2746(97)90031-8 ↗
5. Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system10.1002/jor.22970 ↗
6. Castañeda · 2018
7. Corrosion and wear at the modular interface of uncemented femoral stems10.1302/0301-620X.76B1.8300685 ↗
8. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty10.2106/JBJS.K.01352 ↗
9. Taperosis: does head length affect fretting and corrosion in total hip arthroplasty?10.1302/0301-620X.97B7.35149 ↗
10. Finite element analysis of the head–neck taper interface of modular hip prostheses10.1016/j.triboint.2015.01.016 ↗
11. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
12. What is the trouble with trunnions?10.1007/s11999-014-3746-z ↗
13. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors10.1016/j.jbiomech.2019.109424 ↗
14. An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: the role of taper angle mismatch10.1016/j.jmbbm.2017.07.003 ↗
15. The tribological difference between biomedical steels and CoCrMo-alloys10.1016/j.jmbbm.2012.01.007 ↗
16. Current concepts in orthopaedic biomaterials and implant fixation
17. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
18. A multicenter retrieval study of the taper interfaces of modular hip prostheses10.1097/00003086-200208000-00018 ↗
19. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements10.1016/S0736-0266(03)00186-4 ↗
20. Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty10.1007/s00402-008-0660-4 ↗
21. One hundred and fifty years of history of the Morse taper: from Stephen A. Morse in 1864 to complications related to modularity in hip arthroplasty10.1007/s00264-013-1927-0 ↗
22. Influence of stem type on material loss at the metal-on-metal pinnacle taper junction10.1177/0954411914567931 ↗
23. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips10.1016/j.arth.2011.11.007 ↗
24. Ten-year cross-sectional study of mechanically assisted crevice corrosion in 1352 consecutive patients with metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2017.03.020 ↗
25. Flexural rigidity, taper angle, and contact length Affect fretting of the femoral stem trunnion in total hip arthroplasty10.1016/j.arth.2016.02.079 ↗
26. Does taper angle clearance influence fretting and corrosion damage at the head-stem interface? A matched cohort retrieval study10.1053/j.sart.2014.01.002 ↗
27. Maximizing the fixation strength of modular components by impaction without tissue damage10.1302/2046-3758.72.BJR-2017-0078.R2 ↗
28. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study10.1007/s11999-013-3096-2 ↗
29. Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study10.1016/j.arth.2010.05.030 ↗
30. Accelerating failure rate of the ASR total hip replacement10.1302/0301-620X.93B8.26040 ↗
31. Taper junction failure in large-diameter metal-on-metal bearings10.1302/2046-3758.14.2000047 ↗
32. The effects of blood and fat on Morse taper disassembly forces
33. A high prevalence of corrosion at the head-neck taper with contemporary zimmer non-cemented femoral hip components10.1016/j.arth.2015.02.019 ↗
34. Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties10.1007/s11999-012-2502-5 ↗
35. The taper disaster - how could it happen?10.5301/hipint.5000269 ↗
36. Effect of impact assembly on the fretting corrosion of modular hip tapers10.1002/jor.20048 ↗
37. Same same but different? 12/14 stem and head tapers in total hip arthroplasty10.1016/j.arth.2017.04.027 ↗
38. Mixing of head-stem components in total hip arthroplasty10.1016/j.arth.2017.04.027 ↗
39. Variations in the trunnion surface topography between different commercially available hip replacement stems10.1002/jor.22741 ↗
40. Taper design affects failure of large-head metal-on-metal total hip replacements10.1007/s11999-013-3115-3 ↗
41. [Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head]10.1515/BMT.2006.018 ↗
42. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: an in vitro study
43. Morse-type tapers: factors that may influence taper strength during total hip arthroplasty10.1054/arth.2002.33565 ↗
44. Influence of assembly procedure and material combination on the strength of the taper connection at the head–neck junction of modular hip endoprostheses10.1016/j.clinbiomech.2011.08.002 ↗
45. Effect of manufacturing tolerances on the micromotion at the Morse taper interface in modular hip implants using the finite element technique10.1016/0142-9612(96)88713-8 ↗
46. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗
47. Characterization of solid products of corrosion generated by modular-head femoral stems of different designs and materials
48. Trunnion failure of the recalled low friction ion treatment cobalt chromium alloy femoral head10.1016/j.arth.2017.03.075 ↗
49. Basic principles and uniform terminology for the head-neck junction in hip replacement10.5301/hipint.5000204 ↗
50. The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study10.2106/JBJS.M.01199 ↗
51. Effect of surface roughness and taper angle on junction strength of modular biomedical implant