Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations
Source abstract
Abstract
This study evaluated the effect of the CAD/CAM burs experience (newer vs older as consequence of the milling sequence) on fatigue failure load (FFL), number of cycles for failure (CFF), and survival rates of lithium disilicate glass-ceramic simplified restorations adhesively cemented to a dentin analogue substrate. Three sets of CAD/CAM burs were used to mill disc-shaped ceramic specimens (1 bur set - 18 milled discs with 10 mm diameter and 1.5 mm thickness), considering the bur experience as a result of the milling sequence to compose the study groups: G1-6 - discs obtained from the 1st to 6th milling of each bur set; G7-12 - specimens from the 7th to 12th milling; G13-18 - discs from the 13th to 18th. Discs of dentin analogue (G10, 10 mm diameter and 2.0 mm thickness) were made to serve as substrate (base material) and randomly assigned into pairs with the respective ceramic discs. Then, the ceramic discs were adhesively cemented onto the dentin analogue substrate, composing a three-layer specimen that mimics a monolithic restoration of a posterior tooth. Specimens were tested under stepwise fatigue approach: frequency = 20 Hz, 5000 cycles at maximum load of 400 N to accommodate the testing assembly, followed by incremental steps of 200 N with initial load ranging from 10 to 1000 N, to a maximum of 20,000 cycles/each step, until the occurrence of failure (radial crack). FFL and CFF were recorded at the end of the testing and subjected to statistical analysis. Supplementary roughness analysis of the milled surface was performed (n = 18) using a contact profilometer. Residual stress after milling and acid etching were accessed via X-ray Diffractometry analysis. FFL and CFF were not affected by increase on bur experience (no statistical differences among groups), despite that, it affected both Ra and Rz parameters (G1-6 had the smoothest surface). The residual stress concentration was negligible (milling did not induce residual stress concentration). It is concluded that the fatigue behavior of adhesively cemented lithium-disilicate glass-ceramic restorations was not influenced by CAD/CAM bur experience (newer vs older as consequence of the milling sequence), and so the residual stress concentration induced by milling was negligible.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Machining variability impacts on the strength of a “chair-side” CAD-CAM ceramic10.1016/j.dental.2012.04.017 ↗
2. The impact of hydrofluoric acid surface treatments on the performance of a porcelain laminate restorative material10.1016/j.dental.2006.03.002 ↗
3. Surface quality of yttria-stabilized tetragonal zirconia polycrystal in CAD/CAM milling, sintering, polishing and sandblasting processes10.1016/j.jmbbm.2016.08.021 ↗
4. Fatigue resistance of Y-TZP/Porcelain crowns is not influenced by the conditioning of the intaglio surface10.2341/14-166-L ↗
5. Tensile stress in glass-ceramic crowns: effect of flaws and cement voids
6. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations10.1038/sj.bdj.2008.350 ↗
7. Campos · 2017
8. Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process10.1016/j.prosdent.2013.09.020 ↗
9. The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses10.1016/j.dental.2014.05.018 ↗
10. Influence of CAD-CAM diamond bur deterioration on surface roughness and max- imum failure load of Y-TZP-based restorations
11. Grinding damage assessment for CAD-CAM restorative materials10.1016/j.dental.2016.12.004 ↗
12. The effect of internal roughness and bonding on the fracture resistance and structural reliability of lithium disilicate ceramic10.1016/j.dental.2017.09.018 ↗
13. Denry · 2010 · vol 3 · 351
14. Emerging ceramic-based materials for dentistry10.1177/0022034514553627 ↗
15. How and when does fabrication damage adversely affect the clinical performance of ceramic restorations?10.1016/j.dental.2012.07.001 ↗
16. Fatigue resistance of teeth restored with cuspal-coverage composite restorations
17. Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics10.1016/j.dental.2017.07.019 ↗
18. Hard machining, glaze firing and hydrofluoric acid etching: do these procedures affect the flexural strength of a leucite glass-ceramic?10.1016/j.dental.2015.04.005 ↗
19. CAD/CAM polymer vs direct composite resin core buildups for endodontically treated molars without ferrule10.2341/14-256-L ↗
20. Computer-assisted technologies used in oral rehabilitation and the clinical documentation of alleged advantages - a systematic review10.1111/joor.12483 ↗
21. Fracture surface analysis of dental ceramics: clinically failed restorations
22. Ceramics in dentistry: historical roots and current perspectives10.1016/S0022-3913(96)90413-8 ↗
23. Development of a clinically validated bulk failure test for ceramic crowns10.1016/S0022-3913(10)60129-1 ↗
24. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
25. Influence of CAD/CAM tool and material on tool wear and roughness of dental prostheses after milling10.1016/j.prosdent.2014.12.021 ↗
26. Ceramic dental biomaterials and CAD/CAM technology: state of the art10.1016/j.jpor.2014.07.003 ↗
27. Sequential usage of diamond bur for CAD/CAM milling: effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic10.1016/j.jmbbm.2018.12.037 ↗
28. In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers10.1016/S0022-3913(10)60111-4 ↗
29. The nature of machining damage in brittle materials
30. Fatigue failure load of zirconia-reinforced lithium silicate glass ceramic cemented to a dentin analogue: effect of etching time and hydrofluoric acid concentration10.1016/j.jmbbm.2017.09.028 ↗
31. Effect of acid etching on tridimensional microstructure of etchable CAD/CAM materials10.1016/j.dental.2018.03.013 ↗
32. How does hydrofluoric acid etching affect the cyclic load-to-failure of lithium disilicate restorations?10.1016/j.jmbbm.2018.07.040 ↗
33. Hydrofluoric acid concentrations: effect on the cyclic load-to-failure of machined lithium disilicate restorations
34. Microstructure characterization and SCG of newly engineered dental ceramics10.1016/j.dental.2016.03.018 ↗
35. Near-surface damage--a persistent problem in crowns obtained by computer-aided design and manufacturing10.1243/095441105X9363 ↗
36. Valandro LF Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: conventional ceramic etching vs etch & prime one-step primer10.1016/j.dental.2018.04.012 ↗
37. Internal residual stresses in glass-ceramics: a review10.1016/j.jnoncrysol.2012.01.040 ↗
38. Evaluation of subsurface damage in CAD/CAM machined dental ceramics10.1023/A:1008812929476 ↗
39. Material removal mechanisms in precision machining of new materials10.1016/S0890-6955(01)00014-1 ↗
40. Suresh · 1991
41. Dynamic fatigue and strength characterization of three ceramic materials10.1007/s10856-007-0131-4 ↗
42. Fracture surface characterization of clinically failed all-ceramic crowns10.1177/00220345940730120601 ↗
43. Fatigue failure load of feldspathic ceramic crowns after hydrofluoric acid etching at different concentrations
44. Fatigue performance of adhesively cemented glass-, hybrid- and resin-ceramic materials for CAD/CAM monolithic restorations10.1016/j.dental.2019.01.013 ↗
45. The effect of hydrofluoric acid concentration on the fatigue failure load of adhesively cemented feldspathic ceramic discs10.1016/j.dental.2018.01.010 ↗
46. Statistical failure analysis of adhesive resin cement bonded dental ceramics10.1016/j.engfracmech.2006.11.006 ↗
47. Chairside CAD/CAM materials: part 3: cyclic fatigue parameters and lifetime predictions10.1016/j.dental.2018.03.024 ↗
48. Effect of etching time and resin bond on the flexural strength of IPS e.max Press glass ceramic10.1016/j.dental.2014.08.373 ↗
49. Material-removal-rate analysis in the ultrasonic machining of engineering ceramics
50. Damage accumulation and fatigue life of particle-abraded ceramics
51. Fatigue of dental ceramics10.1016/j.jdent.2013.10.007 ↗
52. Load-bearing capacity under fatigue and survival rates of adhesively cemented yttrium-stabilized zirconia polycrystal monolithic simplified restorations10.1016/j.jmbbm.2018.11.009 ↗